00045979.DOC, Version 1.1
27/28
Control-channel 6 - Dimmer intensity
Decimal Hexad. Percentage S/F
Feature
0 255
00 FF
0% 100%
F
Gradual adjustment of the dimmer intensity from 0 to 100 %
Control-channel 7 - Motion macros
Decimal Hexad. Percentage S/F
Feature
0 7
00 07
0% 3%
S
No function
8 25
08 19
3% 10%
S
Motion macro 1
26 43
1A 2B
10% 17%
S
Motion macro 2
44 61
2C 3D
17% 24%
S
Motion macro 3
62 79
3E 4F
24% 31%
S
Motion macro 4
80 97
50 61
31% 38%
S
Motion macro 5
98 115
62 73
38% 45%
S
Motion macro 6
116 133
74 85
45% 52%
S
Motion macro 7
134 151
86 97
53% 59%
S
Motion macro 8
152 169
98 A9
60% 66%
S
Motion macro 9
170 187
AA BB
67% 73%
S
Motion macro 10
188 205
BC CD
74% 80%
S
Motion macro 11
206 223
CE DF
81% 87%
S
Motion macro 12
224 241
E0 F1
88% 95%
S
Motion macro 13
242 255
F2 FF
95% 100%
S
Motion macro 14
Control-channel 8 - Speed Motion macros
Decimal Hexad. Percentage S/F
Feature
0 255
00 FF
0% 100%
F
Increasing speed
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!