30248372_V_1_1.DOC
13/15
4.2 Description of the device
(1)
19“ rack mounting holes
(2)
Phase indicating control lamps
(3)
C16A circuit breaker
(4)
Power distribution sockets
(5)
32A three-phase-current output socket
(6)
32A three-phase-current input plug
5. INSTALLATION
DANGER TO LIFE!
Please consider the DIN 15560 and the respective national norms during the
installation! The installation must only be carried out by an authorized dealer!
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
A skilled person has to approve the flying construction before every use. This approval includes appearance
and load tests when moved in accordance with the BGV-A2 for electrical devices.
5.1 Rack-Installation
This power distributor is built for 19" racks (483 mm). The rack you use should be a Double-Door-Rack
where you can open the frontpanel and the rear panel. The rack should be provided with a cooling fan. When
mounting the power distributor into the rack, please make sure that there is enough space around the device
so that the heated air can be passed on. Steady overheating will damage your device.