00074920, Version 1.0
19/23
If you are using controllers with this occupation, you can connect the DMX output of the controller directly
with the DMX input of the first device in the DMX chain. If you wish to connect DMX controllers with other
XLR outputs, you need to use adapter cables.
Building a serial DMX chain:
Connect the DMX output of the first device in the DMX chain with the DMX input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution:
At the last fixture, the DMX cable has to be terminated. Plug the terminator with a
120
Ω
resistor
between Signal (–) and Signal (+) in the DMX output of the last fixture.
Connection between devices
On the rear panel, there is an IEC socket (Power Out). Connect the output with the input of the next fixture
until all fixtures are connected.
Attention:
It is recommended to renew the connection with the power mains after every
8
devices.
Master/Slave-Operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear of the device you can find an XLR-jack (DMX Out) and an XLR-plug (DMX In), which can be
used for connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX cable. Connect the DMX
OUT jack with the DMX IN plug of the next device.
Set the Master device to one of the Stand Alone modes ("
p---
" or "
Snd
") and set each Slave device to the
same DMX address "
d001
".
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION