00042053.DOC, Version 1.0
28/31
5.3 Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
Showlasers must provide a manual safety shutdown enabling to interrupt the laser radiation at any time by
force. If the laser product is installed in the trussing system or in an unaccessible location, it must at least be
installed with a switchable power outlet.
5.4
Adjusting the laser
Switch the device on via the power switch.
Loosen the fixation screws of the mounting bracket and adjust the laser product to the desired projection
area.
Call up all desired projection patterns in order to make sure that the projections only move in the
inaccessible showlaser area.
Make sure that no mirrorballs, shining surfaces etc. are located in the laser beam. Shining objects must be
removed from the laser area or be covered.
Tighten the fixation screws of the mounting bracket so that the laser beam cannot be moved without tools.
5.5 Master/Slave-Operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the device you can find an XLR-jack and an XLR-plug, which can be used for
connecting several devices (max. 6 slaves).
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a stereo shielded cable. Connect
the OUT-jack with the IN-plug of the next device.
Set DIP-switch No. 10 to ON in order to determine the Slave device.
5.6 DMX-512 connection / connection between fixtures
The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.