![EuroLite PAR-46 CDM-70 E-27 Spot Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/eurolite/par-46-cdm-70-e-27-spot/par-46-cdm-70-e-27-spot_user-manual_2438571015.webp)
00062420.DOC, Version 1.0
15/18
The lamp has to be replaced when it is damaged
or deformed due to the heat!
CAUTION!
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1:
Remove the color filter frame.
Step 1:
If replacing the lamp, remove the old lamp from the spot.
Step 2:
Screw the new 240 V/ 70W CDM PAR-30 E-27 lamp into the lamp socket.
Step 6:
Replace the color filter frame.
Keep exchanged lamp in a protective container and remove accordingly.
Do not operate this device without the color filter frame!
Overhead rigging
DANGER TO LIFE!
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.