background image

 

Bedienungsanleitung
User Manual

LED
IP T-BAR 16

QCL Outdoor Bar

LED IP T-Bar 16 QCL Bar

Wetterfeste (IP65) Leiste mit RGBW-Farbmischung, incl. IR-Fernbedienung
Weatherproof (IP65) bar with RGBW color mixing, incl. IR remote control

No. 51914107

www.eurolite.de

MASTER

SLAVE

STAND
ALONE

DMX

IP65

STROBE

RGBW

20°

REMOTE

CONTROL

Содержание LED IPT-BAR 16

Страница 1: ...or Bar LED IP T Bar 16 QCL Bar Wetterfeste IP65 Leiste mit RGBW Farbmischung incl IR Fernbedienung Weatherproof IP65 bar with RGBW color mixing incl IR remote control No 51914107 www eurolite de MASTER SLAVE STAND ALONE DMX IP65 STROBE RGBW 20 REMOTE CONTROL ...

Страница 2: ...00129165 Version 1 0 2 32 ...

Страница 3: ...res 17 SAFETY INSTRUCTIONS 18 DESCRIPTION OF THE DEVICE 20 INSTALLATION 21 DMX512 CONTROL 22 POWER SUPPLY 22 OPERATION 23 Operating buttons 23 Menu structure 23 Stand alone mode 24 Remote control IR 7 25 DMX operation 26 CLEANING AND MAINTENANCE 28 PROTECTING THE ENVIRONMENT 28 TECHNICAL SPECIFICATIONS 29 Accessories 29 Diese Bedienungsanleitung gilt für die Artikelnummer This user manual is valid...

Страница 4: ... oder Benutzer des Produkts weitergeben sich die letzte Version der Anleitung im Internet herunter laden EINFÜHRUNG Wir freuen uns dass Sie sich für eines unserer Produkte entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Produktmerkmale Wetterfeste IP65 Leiste mit RGBW Farbmischung inkl IR Fernbedienung 16 leistungsstar...

Страница 5: ...achtung kann zu Schäden am Gerät und zu Verletzungen des Benutzers führen Bei Verwendung im Freien muss immer eine Gummischlauchleitung H05RN F oder H05RR F verwendet werden Bei Verlegung im Erdreich muss ein Erdkabel NYY verwendet werden Alle geltenden Vorschriften zur Installation von Kabeln im Freien bzw im Erdreich müssen unbedingt eingehalten werden Die Steckdose muss gut zugänglich sein dami...

Страница 6: ...gen und oder zur Beschädigung von Eigentum führen Der Hersteller haftet nicht für Schäden die durch unsachgemäße Installation und unzureichende Sicher heitsvorkehrungen verursacht werden Bei einer Montage über Kopf ist das Gerät immer durch eine zweite Befestigung z B Fangseil oder Fangnetz zu sichern Während Montage und Wartungsarbeiten muss der Bereich unterhalb des Geräts abgesperrt sein Bei ge...

Страница 7: ...Fangseilöse 2 RGBW LED 3 Feststellschraube 4 Hängebügel Standfuß 5 Druckausgleichsstopfen 6 Netzausgang 7 DMX Ausgang 8 MENU Taste 9 UP Taste 10 Display 11 DOWN Taste 12 ENTER Taste 13 DMX Eingang 14 Netzanschluss 6 7 8 13 14 5 9 10 11 12 1 3 4 2 1 ...

Страница 8: ...form aus 3 Verwenden Sie Montagematerial das für die Struktur geeignet ist und die Last des Geräts tragen kann Geeignetes Montagematerial finden Sie im Abschnitt Zubehör 4 Sichern Sie das Gerät mit einem Fangseil oder einer anderen geeigneten Einrichtung zusätzlich ab Diese zweite Aufhängung muss auf Grundlage der aktuellsten Arbeitsschutzbestimmungen ausreichend dimensioniert und so angebracht se...

Страница 9: ...ZANSCHLUSS Das Gerät verfügt über ein Schaltnetzteil das eine Netzspannung zwischen 100 und 240 Volt erlaubt 1 Schließen Sie das beiliegende Netzkabel an und stecken den Netzstecker in eine geerdete Schutzkontaktsteckdose ein Damit ist das Gerät eingeschaltet 2 Zum Ausschalten ziehen Sie den Netzstecker aus der Steckdose 3 Schließen Sie das Gerät nicht über einen Dimmer an die Netzspannung an Für ...

Страница 10: ...te beim Einstellvorgang Menüstruktur Modus Anzeige Funktion DMX Betrieb Addr 9CH d001 512 9 Kanal Modus und Startadresse 6CH d001 512 6 Kanal Modus und Startadresse 5CH d001 512 5 Kanal Modus und Startadresse 4CH d001 512 4 Kanal Modus und Startadresse 3CH d001 512 3 Kanal Modus und Startadresse Farbvoreinstellungen Stat S 01 S 19 Konstantes Leuchten in einer von 19 Farben Automatikbetrieb Auto Au...

Страница 11: ...e MENU so oft bis das Display die Betriebsart Colo anzeigt Bestätigen Sie mit der Taste ENTER 2 Das Display zeigt nun den Buchstaben R für die Farbe Rot an und den dazugehörigen Intensitätswert Stellen Sie mit den Tasten UP und DOWN den gewünschten Wert ein 3 Bestätigen Sie mit der Taste ENTER Jetzt kann die Grundfarbe Grün eingestellt werden danach Blau und Weiß Gesamthelligkeit Im Menu diMM läss...

Страница 12: ...tellung ON Halten Sie beim Betätigen einer Taste die Fernbedienung immer in Richtung des Sensors auf der Gerätevorderseite Zwischen Fernbedienung und Sensor muss Sichtverbindung bestehen In der DMX und der Slave Betriebsart sind die Funktionen der Fernbedienung deaktiviert Taste Funktion BLACKOUT LEDs aus AUTO Automatikbetrieb Programmwahl mit STROBE Strobe Effekt für Automatikbetrieb Blitzrate ei...

Страница 13: ... für die DMX Startadresse wird aufgerufen Addr Stellen Sie die Adresse mit den Tasten UP und DOWN ein Bestätigen Sie mit der Taste ENTER 4 Werden keine DMX Steuersignale empfangen blinkt das Display Hinweis Bitte vergewissern Sie sich dass sich die Steuerkanäle nicht mit anderen Geräten überlappen damit das Gerät korrekt und unabhängig von anderen Geräten in der DMX Verbindung funktioniert Werden ...

Страница 14: ...schwindigkeit Auto Programm langsam schnell 6 Kanal Modus Kanal Wert Funktion 1 000 255 Rot 0 100 2 000 255 Grün 0 100 3 000 255 Blau 0 100 4 000 255 Weiß 0 100 5 Master Dimmer 000 255 Gesamthelligkeit 0 100 6 000 000 Keine Funktion 001 005 Automatischer Farbwechsel 006 009 Keine Funktion 010 255 Strobe Effekt Strobe mit zunehmender Geschwindigkeit 9 Kanal Modus Kanal Wert Funktion 1 Master Dimmer...

Страница 15: ...n das Gerät 3 Das Gerät muss trocken sein bevor Sie es wieder einschalten Im Geräteinneren befinden sich keine zu wartenden Teile Öffnen Sie das Gehäuse nicht Unternehmen Sie keine Reparaturversuche da dies ein Sicherheitsrisiko darstellt Wartungs und Servicearbeiten sind ausschließlich dem autorisierten Fachhandel vorbehalten Sollten einmal Ersatzteile benötigt werden verwenden Sie bitte nur Orig...

Страница 16: ...rnbedienung mitgeliefert Abstrahlwinkel 1 2 Peak 20 Abstrahlwinkel 1 10 Peak 35 Gehäusefarbe Schwarz Länge 106 50 cm Höhe 12 65 cm Tiefe 10 00 cm Gewicht 4 9 kg Fernbedienung Batterie 1 x Knopfzelle 3 0 V CR2025 Lithium Mangan Zubehör EUROLITE TPC 10 Klammer silber Best Nr 59006856 EUROLITE Sicherungsseil A 4x1000mm bis 15kg silber Best Nr 58010320 EUROLITE Kombikabel DMX IP T Con 3 Pin XLR 3m Bes...

Страница 17: ...oduct download the latest version of the user manual from the Internet INTRODUCTION Thank you for having chosen one of our products If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Product features Weatherproof IP65 bar with RGBW color mixing incl IR remote control 16 high power 8 W RGBW LEDs 4in1 Suitable for external use IP...

Страница 18: ...o do so could possibly injure the user For outdoor use make sure to connect a rubber cable H05RN F or H05RR F For installations in the ground an underground power cable NYY must be used All valid instructions concerning the installation of cables outdoors or in the ground must be adhered The mains outlet must be easily accessible so that you can unplug the device quickly if need be Never touch the...

Страница 19: ...not be made liable for damages caused by incorrect installations or insufficient safety precautions For overhead use always secure the device with a secondary safety attachment such as a safety bond or safety net Make sure that the area below the installation place is blocked when rigging derigging or servicing the device For commercial use the country specific accident prevention regulations of t...

Страница 20: ...1 Safety eyelet 2 RGBW LED 3 Fixation screw 4 Mounting bracket foot 5 Pressure compensation plug 6 Power output 7 DMX output 8 MENU button 9 UP button 10 Display 11 DOWN button 12 ENTER button 13 DMX input 14 Power input 6 7 8 13 14 5 9 10 11 12 1 3 4 2 1 ...

Страница 21: ...ompatible with the structure and capable of bearing the weight of the device Please refer to the Accessories section for a list of suitable rigging hardware 4 Secure the device with a safety bond or other secondary attachment This secondary safety attachment must be sufficiently dimensioned in accordance with the latest industrial safety regulations and constructed in a way that no part of the ins...

Страница 22: ... SUPPLY The device uses an auto range power supply that accepts input voltages between 100 und 240 volts 1 Connect the device via the mains cable to a grounded mains socket Thus the unit is switched on 2 To switch off the unit disconnect the power plug 3 Do not connect the unit to the mains voltage via a dimmer For a more convenient operation use a mains outlet which is switchable 4 The jack POWER...

Страница 23: ...ecreases values when modifying Menu structure Mode Display Function DMX mode Addr 9 CH d001 512 9 channel mode and start address 6 CH d001 512 6 channel mode and start address 5 CH d001 512 5 channel mode and start address 4 CH d001 512 4 channel mode and start address 3 CH d001 512 3 channel mode and start address Preset colors Stat S 01 S 19 Constant lighting in one of 19 colors Automatic mode A...

Страница 24: ...til Colo is indicated in the display Confirm with the ENTER button 2 Now the display indicates the letter R for the color red and the corresponding intensity value Use the buttons UP and DOWN to adjust the desired intensity 3 Confirm with the ENTER button Now the color green can be set then blue and then white until the desired color intensity is achieved Total brightness The menu point dIMM allow...

Страница 25: ... for remote control For this set menu item InFr to ON When actuating a button always direct the remote control towards the sensor There must be no obstacles between remote control and the sensor Button Function BLACKOUT LEDs off AUTO Automatic mode program selection with STROBE Strobe effect for automatic mode flash rate setting with SPEED Running speed in automatic mode setting with DMX DMX mode ...

Страница 26: ...m for the DMX starting address Addr Use the buttons UP and DOWN to set the address Confirm with the ENTER button 4 If no DMX control signals are available the display will flash Note Please make sure that you do not have any overlapping channels in order to control each device correctly and independently from any other fixture on the DMX chain If several devices are addressed similarly they will w...

Страница 27: ...3 000 255 Blue 0 100 4 000 255 White 0 100 5 Master Dimmer 000 255 Increasing brightness 0 100 6 000 000 No function 001 005 Automatic color change 006 009 No function 010 255 Strobe effect with increasing speed 0 100 9 channel mode Channel Value Function 1 Master dimmer 000 255 Increasing brightness 0 100 2 Strobe effect 000 009 No function 010 255 Strobe with increasing speed 0 100 3 000 255 Red...

Страница 28: ...serviceable parts inside Do not open the housing Do not try to repair the device by yourself as this may result in damage Maintenance and service operations are only to be carried out by authorized dealers Should you need any spare parts please use genuine parts Should you have further questions please contact your dealer PROTECTING THE ENVIRONMENT Disposal of old equipment When to be definitively...

Страница 29: ...on Stand alone IR remote control provided Beam angle 1 2 peak 20 Beam angle 1 10 peak 35 Housing color Black Length 106 50 cm Height 12 65 cm Depth 10 00 cm Weight 4 9 kg Remote control Battery 1 x Button cell 3 0 V CR2025 lithium manganese Accessories EUROLITE TPC 10 Coupler silver No 59006856 EUROLITE Safety Bond A 4x1000mm up to 15kg silver No 58010320 EUROLITE Combi Cable DMX IP T Con 3 pin XL...

Страница 30: ......

Страница 31: ......

Страница 32: ...Eurolite is a brand of Steinigke Showtechnic GmbH Andreas Bauer Str 5 97297 Waldbüttelbrunn Germany D00129165 Version 1 0 Publ 13 05 2020 ...

Отзывы: