background image

00048553.DOC, Version 1.1

11/14

Never use the device during thunderstorms. Over voltage could destroy the device. Always disconnect the
device during thunderstorms.

The symbol 

- - -m

determines the minimum distance from lighted objects. The minimum distance

between light-output and the illuminated surface must be more than 0.1 meters.

Make sure that the area below the installation place is blocked when rigging, derigging or servicing the
fixture.

The maximum ambient temperature 

T

a

= 45° C must never be exceeded.

Operate the device only after having become familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional operation!

Please use the original packaging if the device is to be transported.

Please consider that unauthorized modifications on the device are forbidden due to safety reasons!

If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, crash etc.

INSTALLATION

The device can be installed on the ground or on the wall or ceiling.

Overhead rigging

DANGER TO LIFE!

Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!

The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.

The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.

When rigging, derigging or servicing the device staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.

The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.

The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.

The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.

Procedure:

The device should be installed outside areas where persons may walk by or be seated.

IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all

Содержание LED Bar 12V RGB 100cm

Страница 1: ...Copyright Nachdruck verboten Reproduction prohibited F r weiteren Gebrauch aufbewahren Keep this manual for future needs BEDIENUNGSANLEITUNG USER MANUAL LED Bar 12V RGB 100cm...

Страница 2: ...N 8 INTRODUCTION 9 Features 9 SAFETY INSTRUCTIONS 9 OPERATING DETERMINATIONS 10 INSTALLATION 11 Overhead rigging 11 Connection to Controller EUROLITE LED PSI 1 DMX 13 CLEANING AND MAINTENANCE 13 TECHN...

Страница 3: ...Ihrem Kauf haben werden Nehmen Sie die LED Bar 12V RGB 100cm aus der Verpackung Features Formsch ne LED Leiste bietet neue Gestaltungsm glichkeiten Bestens geeignet zu Beleuchtungs und Dekorationszwec...

Страница 4: ...SGEM SSE VERWENDUNG Bei diesem Ger t handelt es sich um einen Effektstrahler mit dem sich dekorative Lichteffekte erzeugen lassen Dieses Produkt ist nur f r die auf dem Typenschild angegebene Spannung...

Страница 5: ...die Originalverpackung um Transportsch den zu vermeiden Beachten Sie bitte dass eigenm chtige Ver nderungen an dem Ger t aus Sicherheitsgr nden verboten sind Wird das Ger t anders verwendet als in die...

Страница 6: ...dass die Montagefl che mindestens die 10 fache Punktbelastung des Eigengewichtes des Ger tes aushalten kann Achten Sie bei der Installation des Ger tes bitte darauf dass sich im Abstand von mind 0 5 m...

Страница 7: ...usg nge des LED PSI 1 DMX Contollers kann jeweils eine LED Bar angeschlossen werden Hinweis Die maximale L nge der Verbindungskabel zwischen Leuchte und Controller betr gt 50 m REINIGUNG UND WARTUNG V...

Страница 8: ...derzeit gerne zur Verf gung TECHNISCHE DATEN Spannungsversorgung 12 V DC Gesamtanschlusswert 18 W Maximale Umgebungstemperatur Ta 45 C Max Leuchtentemperatur im Beharrungszustand TB 55 C Mindestabstan...

Страница 9: ...ice for a long period of time Unpack your LED Bar 12V RGB 100cm Features Handsome LED bar offers new creative possibilities Perfect for decorative and illumination purposes i e in stairways cinemas th...

Страница 10: ...the voltage given on the type plate and was designed for indoor use only This device is designed for professional use e g on stages in discotheques theatres etc Lighting effects are not designed for...

Страница 11: ...tive national standards during the installation The installation must only be carried out by an authorized dealer The installation of the device has to be built and constructed in a way that it can ho...

Страница 12: ...te safety bond You must only use safety bonds complying with DIN 56927 quick links complying with DIN 56927 shackles complying with DIN EN 1677 1 and BGV C1 carbines The safety bonds quick links shack...

Страница 13: ...naire and controller may not exceed 50 m CLEANING AND MAINTENANCE Disconnect from mains before starting maintenance operation DANGER TO LIFE We recommend a frequent cleaning of the device Please use a...

Страница 14: ...using temperature TB steady state 55 C Min distance from flammable surfaces 0 5 m Min distance to lighted object 0 1 m Number of 10mm LEDs 243 RGB Beam angle 30 Dimensions LxWxH 980 x 80 x 100 mm Weig...