00041214.DOC, Version 1.0
32/32
Clean the front glass every two weeks from dust and smoke fluid residues.
There are no servicable parts inside the device. Never open the housing! Maintenance and service
operations are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Open the fuseholder on the rear panel with a fitting screwdriver.
Step 2:
Remove the old fuse from the fuseholder.
Step 3:
Install the new fuse in the fuseholder.
Step 4:
Replace the fuseholder in the housing.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
8. TECHNICAL SPECIFICATIONS
Power supply:
230 V AC, 50 Hz ~
Power consumption:
20 W
DMX-control-channels:
7
DMX-512-connection:
3-pin XLR
Maximum optical power:
10 mW
Laser classification:
3B
Wavelength:
532 nm
Beam:
approx. 12 mm / 1 mrad
Scanning speed:
2,000 pps
Dimensions without bracket (LxWxH):
300 x 390 x 230 mm
Weight:
15 kg
Fuse:
F 1 A, 250 V
Please note: Every information is subject to change without prior notice. 02.12.2008 ©