00062123.DOC, Version 1.1
17/20
MODE
UP DOWN
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
Before starting operation make sure that the cloth cannot be drawn into the intake of the ventilation fan.
After you connected the effect to the mains, the AC-300 DMX LED/RGB Base starts running.
The LED display lights up and you can choose the desired settings.
The device has two operating modes. It can be operated in Stand Alone or in DMX-controlled mode.
- STAND ALONE-MODE
•
Setting Solid Colors
•
Internal Programs
- DMX MODE
STAND ALONE-MODE
In Stand Alone Mode, the AC-300 DMX LED/RGB Base can be used without a controller.
Disconnect the device from the controller.
Control Board
The Control Board offers several features: you can run the internal programs or
set the starting address.
Browse through the main menu by pressing MODE. You can change the
selection by pressing UP or DOWN. The functions provided are described in
the following sections.
Setting Solid Colors
Press the MODE button to select the solid color mode. When the display shows
C
, you can select the
desired solid color via the UP or DOWN buttons (see following graphic).
Mode:
Value:
Function:
C1
Red
C2
Green
C3
Blue
C4
Cyan
C5
Magenta
C6
Yellow
C
C7
White