00066178.DOC, Version 1.0
21/23
Sound Control / Sensitivity
Press the MODE button until the display shows
S
. You can select the desired sensitivity via the UP or
DOWN buttons.
Mode:
Value
S
S00 - S99 (S50 default)
DMX MODE
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the LED PAR-56 TCL Short Spot will respond to the controller.
Addressing
Press the MODE button until the display shows
Add
. You can now set the desired address via the UP or
DOWN buttons.
Setting the DMX Start Address:
Mode:
Value:
Add
001 - 512
Controlling:
After having addressed the LED PAR-56 TCL Short Spot, you may now start operating it via your lighting
controller.
Note:
It’s necessary to insert the XLR termination plug with 120
in the last lighting in the link in order to ensure
proper transmission on the DMX data link.
Choosing a DMX Channel Mode with 3 or 5 Channal Occupation
The device has 2 DMX-modes. The Control Board allows you to assign the DMX-Mode.
Setting DMX Mode
After setting the desired address via the UP or DOWN buttons, press the MODE button again and the
display shows 5ch.
In case you would rather select the 3-channel mode, press the DOWN button in order to choose the 3ch
setting.
Mode:
Value:
5ch (default setting)
3ch