OPERATION

 EN 

 

Single-color LEDs 

If  the  DIP  switch  has  been  set  to  the  operating  mode  DIM,  the  following  functions  can  be 
controlled  with  the  remote  control.  The  remote  control  switches  to  stand-by  mode  after  8 
seconds of inactivity and can be reactivated by pressing any button. 

 

 

 

Button 

Function 

 

No function 

 

Power on 

 

Power off 

Dimmer ring 

Adjusting brightness clockwise   

 

Mode selection: flashing, fade 

 

Reduce brightness by 10% (Nightlight function) 

   

Reduce brightness in 5

 levels

 (10 %, 30 %, 50 %, 70 %, 100 %) 

   

Increase brightness in 5 

levels

 (10 %, 30 %, 50 %, 70 %, 100 %) 

 

Reduce brightness in 1024 

levels

                                                                         

(Keep button pressed to proceed quicker) 

 

Increase brightness in 1024 

levels

                                                                         

(Keep button pressed to proceed quicker)   

 

Reduce speed for dynamic programs in 100

 levels

 

(Keep button pressed to proceed quicker) 

 

 

Increase speed for dynamic programs in 100 

levels

 

(Keep button pressed to proceed quicker)   

 

Select zones 1-4 (status indicator lights),                                                                                                                         
keep pressed for 2 seconds to select all zones (all status indicators light) 

 

RF signal indicator 

ON 

 

 

Mode 

 

 

Brig (5 levels) 

Brig (1024 levels) 

Speed + 

Zone indicators 

SET 

OFF 

 

Dimmer ring 

 

 

Nightlight 

Brightness ‒ (5 levels) 

Brightness ‒ (1024 levels) 

Speed ‒ 

 

Zone selection 

(keep pressed for 2 seconds 

for all zones) 

Содержание 50531140

Страница 1: ...he correct use of your product Please keep them for future reference SAFETY INSTRUCTIONS Only use the product according to the instructions given herein Damages due to failure to follow these operatin...

Страница 2: ...er supply connect a regulated power supply unit min 12 V max 24 V to the negative and positive INPUT terminals Use the DIP switches to select the operating mode according to the connected LEDs RGB RGB...

Страница 3: ...V CH1 V CH2 V CH3 V CH4 V Application example 2 White LEDs CW WW with variable color temperature V V CH1 CW CH2 WW CH3 CW CH4 WW Application example 3 RGB LEDs V V CH1 R CH2 G CH3 B CH4 not connected...

Страница 4: ...g each other As a result all dynamic and static color settings run in sync and there is no visible difference to a wired system Please note 1 The devices are not paired by default Each remote control...

Страница 5: ...button 4 The connected LEDs flash three times and then return to their previous state The devices have been paired successfully Resetting the receiver After being reset to factory settings the receiv...

Страница 6: ...g if the previously used remote control was lost and needs to be replaced Step Procedure Remarks 1 Switch off the receiver 2 Keep the M ODE button on the remote control pressed for 5 seconds The RF i...

Страница 7: ...tness in 5 levels 10 30 50 70 100 Reduce brightness in 1024 levels Keep button pressed to proceed quicker Increase brightness in 1024 levels Keep button pressed to proceed quicker Reduce speed for dyn...

Страница 8: ...10 30 50 70 100 Reduce brightness in 1024 levels Keep button pressed to proceed quicker Increase brightness in 1024 levels Keep button pressed to proceed quicker Reduce speed for dynamic programs in...

Страница 9: ...quicker Reduce speed for dynamic programs in 100 levels Keep button pressed to proceed quicker Increase speed for dynamic programs in 100 levels Keep button pressed to proceed quicker Select zones 1 4...

Страница 10: ...n 1024 levels keep button pressed to proceed quicker Reduce speed for dynamic programs in 100 levels keep button pressed to proceed quicker Increase speed for dynamic programs in 100 levels keep butto...

Страница 11: ...t 20 mA Dimensions LxWxH 164 x 45 x 26 mm Weight 0 95 g Receiver Power supply 12 24 V DC Standby current 1 W Output power max 288 W 12 V 576 W 24 V Load max 6 A per channel 24 A overall load Protectiv...

Страница 12: ...e of them separately from the product You as the end user are required by law Battery Ordinance to return all used batteries rechargeable batteries Disposing of them in the household waste is prohibit...

Отзывы: