00026111.DOC, Version 2.1
16/16
The examination intervals for mobile electrical devices (German BGV A2) must be kept.
The operator has to make sure that the electrical devices are examined by an electrician before taking into
operation for the first time and after changes before taking into operation another time.
Electrical devices must only be taken into operation in a perfect condition and must be kept this way.
For keeping the perfect condition, electrical devices must repeatedly be approved in accordance with the
instructions given in the electro-technical guidelines.
A qualified electrician is responsible for the correct examinations.
Mobile electrical devices, extension cords with plugs, power cables with plugs and mobile cables with plugs
and permanent installation must be approved by an expert every three months.
Should you have further questions, please contact your dealer.
7. TECHNICAL SPECIFICATIONS
Power supply:
380-400 V AC, 50 Hz ~
Max. power output:
11040 W
Max. total current:
48 A
Max. output/channel (safety socket):
3680 W
Max. current/channel (safety socket):
16 A
Max. output/channel (CEE socket):
3680 W
Max. current/channel (CEE socket):
16 A
Dimensions (LxWxH):
290 x 180 x 95 mm
Weight:
2 kg
Accessories:
No.
EUROLITE TPC-10 Coupler, silver
59006856
EUROLITE Safety Bond A 3x600mm up to 5kg, silver
58010310
PSSO CEE Extension 16A 5x2.5 10m red
30245620
ACCESSORY Tie Straps 25x195mm
30006022
Please note: All information is subject to change without prior notice. 10.09.2018 ©
EUROLITE
is a brand of Steinigke Showtechnic GmbH Andreas-Bauer-Str. 5 97297 Waldbüttelbrunn Germany