Euroheat WIKING MIRO Range Скачать руководство пользователя страница 3

E&OE  Instructions Part number IN1273 Ed A

3

©

 

EUROHEAT

 

DISTRIBUTORS (H.B.S) LTD. Jan 2012

IMPORTANT

.

 The installation of this appliance must comply with all current BS 8303 local regulations, including 

those referring to national and European Standards before it can be operated. The stove is not suitable 
for a shared flue. However, for England and Wales, only, the coming into force on 1st April 2002 of SI 
2002 No 440 exempts the householder from this legal requirement for the installation of solid fuel 
fired appliance whose rated heat output is 50 kW or less in a building having no more than 3 storeys 
(excluding any basement) if a Competent Engineer is employed who is registered under the Registration 
Scheme for Companies and Engineers involved in the Installation and Maintenance of Domestic Solid 
Fuel Fired Equipment operated by HETAS Ltd. These registered Competent Engineers may also carry 
out associated building work necessary to ensure that the installed appliance complies with Building 
Regulations without involving the Local Authority Building Control Department.

  Improper adjustment, alteration, maintenance or the fitting of replacement parts not recommended by 

the manufacturer can cause injury or property damage. Do not operate the stove with faulty seals or 
damaged glass.

  

 

Due to the high operating temperatures of this appliance it should be located away from pedestrian 
traffic and away from furniture and draperies. Do not store paper or wood near the appliance.  Any mats 
and rugs put in front of the stove should be fire proof and secured to prevent the possibility of tripping.

  Advise all persons as to the stove’s high surface temperatures. If it is possible  for children or infirm 

adults to come into contact with the stove, fit a suitable fire guard. 

  It is imperative that all air passageways into, out of, and within  the appliance are kept clean. All 

permanent ventilation into the room provided for the stove must remain clear and unobstructed at all 
times. Consideration must be given to the need for extra ventilation if another heating source needing 
air is to be operated simultaneously. If an extraction fan is proposed to be fitted to a connecting area 
of the house, after the stove has been installed, professional advice should be sought from a qualified 
engineer.

 

 The user should be advised that the appliance should be inspected regularly and the chimney cleaned at 

least annually.

  More frequent cleaning may be required and the advice of a qualified chimney sweep should be sought. 

 

Our range of stoves is capable of operating with outstanding efficiency if the flue system is correct. 
Because so little heat is wasted to the flue it is possible that moisture within the products of combustion 
will condense if the heat losses within the flue way are too great and allow the flue gases to cool. For 
this reason we recommend that the stove is fitted with a suitable flue liner, the same diameter as the 
flue spigot, to prevent the possibility of acidic damage to the fabric of the chimney and damage to the 
stove which will reduce the longevity of the stove.

 

When correctly installed, the stove is designed to produce heat, safely.  It cannot do so if the 
installation is less than absolutely stable, constructed of materials suitable for such an installation  
and consideration has not been given to the possibility of people with less than ideal common sense 
operating it. 

 Have the existing chimney swept by a chimney sweep. Although you will be lining the chimney, any 

deposits left in the chimney will cause problems and may become a fire hazard.

 

Your attention is drawn to the precautions and responsibilities under the Health and Safety at Work Acts, 
and whatever new legislation being introduced during the life of this document.

Содержание WIKING MIRO Range

Страница 1: ...f Stoves The above are suitable for use in smoke control areas Wood Models This manual must always be available to the stove operator Serial Number Part No Model Name This manual must be used in conju...

Страница 2: ...ructions Subject Page Important Notes 3 Model Identification 4 Curing Process 4 About Different Fuels 5 7 The Clean Air Act and Smoke Control Areas 8 Technical Details 8 Hearths 9 Fireplace Design 10...

Страница 3: ...imperative that all air passageways into out of and within the appliance are kept clean All permanent ventilation into the room provided for the stove must remain clear and unobstructed at all times...

Страница 4: ...Euroheat In this way the model and its history will be recorded for reference in the future Whilst we are always happy to assist you please make sure you have read this manual before contacting the t...

Страница 5: ...his will ensure that when the new logs begin releasing gases it will ignite Unburned gases will cause smoke and tar deposits and wastes potential heat Putting on too much wood at one time will both re...

Страница 6: ...o allow air to circulate within the stack and storing it under cover for between 18 months and 30 months depending on prevailing climatic conditions The use of a wood moisture content meter will confi...

Страница 7: ...f they are split halving the tubes and allowing the moisture to evaporate more easily Similarly it also allows the volatile gases given off when the wood is heated in a stove to be emitted along its f...

Страница 8: ...nce exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or ex...

Страница 9: ...s the floor can accommodate the weight of the appliance and its unsupported flue components If it is installed on a wooden floor or similar the floor must be covered with a non combustible material a...

Страница 10: ...ars Golden Mean 1 The stove must always stand perfectly level The provision of a suitable level hearth within the recess is an important consideration when planning a fireplace 2 Sufficient space shou...

Страница 11: ...ible back wall 50mm 1 From combustible back wall 100mm 2 From non combustible side wall 100mm 2 From combustible side wall 520mm 3 hearth in front 300mm 1 Distance to 450 sidewall 380mm 4 Distance fro...

Страница 12: ...tions and makes it possible to over fire the stove which can seriously damage it In this instance a flue draught stabiliser may need to be fitted or if it is wind assisted excessive flue draught a sta...

Страница 13: ...tos in the course of installation then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the po...

Страница 14: ...ser never to operate the stove with the furnace door open and that the user is aware of the requirement of a suitable fire guard where children the old or infirm may come into contact with the applian...

Страница 15: ...E OE Instructions Part number IN1273 Ed A 15 EUROHEAT DISTRIBUTORS H B S LTD Jan 2012...

Страница 16: ...Bishops Frome Worcestershire WR6 5AY Reception 01885 491100 Email info euroheat co uk...