Euroheat Nestor Martin IT13 Скачать руководство пользователя страница 7

© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June. 2010

    

 Instructions Part Number IN1180 Ed.D1

7

A insert is very much safer than an open fire, but if you have children or infirm people in the house please ensure 
it is suitably guarded, and consideration should also be given to accidental contact with the insert if you are 
entertaining with a busy house full of guests.  If you have a remotely operated insert please ensure you keep the 
remote operating handset well away from the insert, children and dogs.

Choice of Fuels

Use of fuels in smoke exempt areas.

If you are operating this stove within a smoke exempt area it is approved for use for the following fuels only:
Seasoned dry wood. With a moisture content of 20% or less
Smokeless coal approved for use in smoke exempt areas.
Other fuels such as house coal, briquettes, waste wood, peat, wood over 20% moisture must not be used unless 
approved for use in smoke exempt areas.

Wood

All wood will burn slightly differently, but the most important differences  between woods is their moisture 
content. Until the moisture has been driven off from the wood it will remain below its combustion temperature. 
When the outer skin has dried and beginning to burn, much of this heat energy will be wasted having to boil 
off the water remaining in the core of the wood. Copious amounts of water vapour, in all but the most insulated 
flue, will condense, and mix with the products of combustion to form creosote and other undesirable substances 
which will eat away the fabric of the flue, and eventually build up to  block the flue. At any time this build up of 
tar will be capable of causing a chimney fire.
The advice to burn only "dry" wood is sometimes confusing because the atmospheric moisture will prevent wood 
ever becoming "dry". It is acceptable to burn wood with a moisture content of less than 20%, which can be 
achieved by splitting the wood, stacking it so as to allow air to circulate within the stack and storing it under cover 
for between 18 months and 30 months, depending on prevailing climatic conditions. The use of a wood moisture 
content meter will confirm the amount of water remaining in the wood easily. The practice of drying wood by the 
insert should be discouraged, firstly because it should be unnecessary, and secondly because stored wood will 
invariably become the home to many varieties of insects, many of  whom enjoy eating wood. To introduce them 
into your house and encourage them with heat and time to make new homes in your furniture and structural 
timbers is not recommended.

Smokeless Coal

We recommend burning deep mined anthracite, a natural hard coal which is classified as being a smokeless fuel; 
specifying the size of “large nuts”  will give most visually attractive and efficient burning. Smaller sizes than 
this will tend to choke the air flow too easily making long burning times without attention problematic. Various 
manufactured smokeless coals are available giving differing burning characteristics and the manufacturers or 
your coal merchant will advise you as to their suitability for inserts. The difficulties and dangers associated with 
burning ordinary bituminous coal (house coal) with its relatively high volatile content make it totally unsuitable 
and potentially dangerous for burning in any insert. 

Lignite 

(also known as solid mineral fuel)

Lignite is obtainable in briquette form and is best described as young coal. It behaves very much like coal and 
should be burned as smokeless manufactured coal. However it is not classified as smokeless and should not be 
used in smoke exempt area`s.

Peat

Peat burns very well, but it is bulky and its distinct aroma will pervade your home and everything in it, but 
otherwise peat can be burned as wood. However it is not classified as smokeless and should not be used in 
smoke exempt area`s.

DO NOT BURN petroleum based fuels such as petro-coke, they may seriously damage your insert. The manufacturers 
of  other  blended  coal  products,  containing  a  proportion  of  petro-coke,  should  be  approached  to  confirm  the 
suitability of the product for use within an enclosed appliance that does not have a chrome steel grate.

Содержание Nestor Martin IT13

Страница 1: ...heat Natural Energy Company PART NUMBER SERIAL NUMBER Operating Instructions Nestor Martin IT13 IN1180 Edition D1 June 2010 This Manual Must Always Be Available To The Stove Operator Exempt Smoke Cont...

Страница 2: ...into the room provided for the insert must remain clear and unobstructed at all times Consideration must be given to the need for extra ventilation if another heating source needing air is to be opera...

Страница 3: ...10 Rotation Stop Button 11 Minimum Air Setting 11 Ash Collection 12 Available Accessories 12 Ash Pan Removal 13 Getting Started with Wood 15 Why Did You Fail 18 Advanced Driving With Wood 19 Slow Ove...

Страница 4: ...urt Farm Business Park Bishops Frome Worcestershire WR6 5AY www euroheat co uk info euroheat co uk Whilst we are always happy to assist you please make sure you have read this manual and have watched...

Страница 5: ...eat approved supplier to obtain your Warranty Registration If any of the Instructions or the Warranty Registration form are missing please contact Euroheat quoting the stoves serial number and a repla...

Страница 6: ...wastes potential heat Putting on too much wood at one time will both restrict the air supply and cool the combustion chamber making it more difficult for the gasses to burn cleanly Never put on fresh...

Страница 7: ...for between 18 months and 30 months depending on prevailing climatic conditions The use of a wood moisture content meter will confirm the amount of water remaining in the wood easily The practice of...

Страница 8: ...o allows the volatile gasses given off when the wood is heated in a insert to be emitted along its full length rather than at the log s ends This helps the gasses to be distributed more evenly within...

Страница 9: ...e Operating Tool To Make Air Direction Adjustments Rotation Stop Button Air Direction Lever When the direction lever is in its uppermost position the air enters the insert above the fire and when set...

Страница 10: ...een 12 O clock and 3 O clock with slow burning being achieved when the control is set between 3 O clock and 6 O clock Do not expect the insert s performance to match any setting repeatedly because it...

Страница 11: ...l not enough to risk damage to the grate but enough to help keep the glass clean It is also an important safety feature If the stove has been burning with a constant air supply it has been generating...

Страница 12: ...st effective way of clearing wood ash when the fire has burned out If the fire has been running on anthracite coal and the insert has been over filled and under riddled the poker may have to be used t...

Страница 13: ...ch has only the hexagon key slot visible The operating tool right angle end is used to engage the ash pan socket Care should be taken to ensure the tool is fully engaged before removing the ash pan Th...

Страница 14: ...e opened and the ash pan removed The ash pit door must be closed immediately the ash pan is removed and the insert door must also be closed securely When re installing the empty ash pan the insert doo...

Страница 15: ...mber that your insert needs the help of a gentle push start in the right direction until it warms Do not expect it to be on auto pilot until it reaches its operating temperature ACME Ensure the ash pa...

Страница 16: ...low the long bright flames to pass between and over the wood raising it to its ignition temperature As the cone of kindling burns it will collapse and the inner ends of the wood will begin to char and...

Страница 17: ...control when the fire is established Never leave it in its lighting position continuously Putting new logs bark side down towards the front of the grate will give you both maximum efficiency and best...

Страница 18: ...determine how much fuel can be loaded at one time but remember you are lighting the insert and wanting it to reach its operating temperature as quickly as possible all smoke is a pollutant and wasted...

Страница 19: ...without staining the glass for many hours If only a low heat output or limited burning time is required the charcoal will be producing much of the heat with an occasional log being loaded for interest...

Страница 20: ...amounts of smoke Unlike driving a car that accelerates and brakes wood burning should be regarded as something that gathers and losses momentum gracefully and all adjustments to the burning rate shou...

Страница 21: ...setting if flames are still visible reducing the air to a minimum will extinguish any flames and cause tar and smoke to be produced Always wait until no more flames are evident before you can safely t...

Страница 22: ...y push start it in the right direction until it warms Do not expect it to be on auto pilot until it reaches its operating temperature Ensure the ash pan is fitted and empty then securely close the ash...

Страница 23: ...until the kindling fire core has lost its large flames and is glowing then wearing the glove lay several pieces of kindling on the top of them followed by pieces of coal Try to leave open spaces betwe...

Страница 24: ...mes but is glowing brightly Fire lighters perform well only if the blocks are protected from fast air flow Setting the air volume to a position between 12 O clock and 3 O clock will provide sufficient...

Страница 25: ...ir volume should now be set to the 12 O clock position New loading of coal should be placed to cover only coals which are glowing It will delay the ignition of coal not already burning if further laye...

Страница 26: ...flames to heat the coal If coals are placed directly over them or the coals were piled too high the vapours will burn above and often seemingly detached from the fire bed rather than under the coals...

Страница 27: ...re that has a restricted air flow risks gasses being released from the coals with insufficient air to burn and suddenly introducing air by riddling the grate may cause the accumulated gasses to ignite...

Страница 28: ...l finishes It should be noted that even approved cleaners will damage the enamel finish of the insert if used too vigorously All traces of the cleaner must be removed before the insert is lit and no f...

Страница 29: ...d back plate until the front of the baffle clears the front locating supports Bring the baffle front below these supports and pull baffle towards the insert front The cast side internal plates are rem...

Страница 30: ...various places with the paper trapped If the seal holds the paper tight and it is difficult to withdraw it then the seal is good If when it is pulled slides out easily then the door catch will need a...

Страница 31: ...ended support if the requirements are not met Any extended warranty requires that the appliance is serviced annual by an approved engineer Euroheat Nestor Martin have a policy of continual research an...

Страница 32: ...491112 Technical 01885 491117 Reception 01885 491100 Need more info with over 10 000 pages of technical information spare parts product shots news and 1001 other things you will not find a more compr...