Euroheat Nestor Martin IN13 Скачать руководство пользователя страница 4

© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010

E & OE        Instructions Part number IN1208  Edition B

4

IMPORTANT

.

 

The  installation  of  this  appliance  must  comply  with  all  local  regulations,  including  those  referring  to 

national and European Standards before it can be operated. The stove is not suitable for a shared flue. However, 
for England and Wales, only, the coming into force on 1st April 2002 of SI 2002 No 440 exempts the householder 
from this legal requirement for the installation of solid fuel fired appliance whose rated heat output is 50kW or 
less in a building having no more than 3 storeys (excluding any basement) if a Competent Engineer is employed 
who  is  registered  under  the  Registration  Scheme  for  Companies  and  Engineers  involved  in  the  Installation 
and Maintenance of Domestic Solid Fuel Fired Equipment operated by HETAS Ltd. These registered Competent 
Engineers may also carry out associated building work necessary to ensure that the installed appliance complies 
with Building Regulations without involving the Local Authority Building Control Department.

 

 

Improper  adjustment, alteration, maintenance or the fitting of replacement parts not recommended by 

the manufacturer can cause injury or property damage. Do not operate the stove with faulty seals or damaged 
glass.
  

 

Due to the high operating temperatures of this appliance it should be located away from pedestrian traffic 

and away from furniture and draperies. Do not store paper or wood near the appliance.  Any mats and rugs put 
in front of the stove should be fireproof and secured to prevent the possibility of tripping.

  

Advise all persons as to the stove’s high surface temperatures. If it is possible for children or infirm adults 

to come into contact with the stove, fit a suitable fire guard. 

  

It is imperative that all air passageways into, out of, and within the appliance are kept clean. All permanent 

ventilation into the room provided for the stove must remain clear and unobstructed at all times. Consideration must 
be given to the need for extra ventilation if another heating source needing air is to be operated simultaneously. 
If an extraction fan is proposed to be fitted to a connecting area of the house, after the stove has been installed, 
professional advice should be sought from a qualified engineer.
 

  

The user should be advised that the appliance should be inspected regularly and the chimney cleaned at 

least annually. More frequent cleaning may be required and the advice of a qualified chimney sweep should be 
sought. 

 

Our  range  of  stoves  is  capable  of  operating  with  outstanding  efficiency  if  the  flue  system  is  correct. 

Because so little heat is wasted to the flue it is possible that moisture within the products of combustion will 
condense if the heat losses within the flue way are too great and allow the flue gasses to cool. For this reason we 
recommend that the stove is fitted with a suitable flue liner, the same diameter as the flue spigot, to prevent the 
possibility of acidic damage to the fabric of the chimney and damage to the stove which will reduce the longevity 
of the stove.

 

When correctly installed, the stove is designed to produce heat, safely.  It cannot do so if the installation 

is less than absolutely stable, constructed of materials suitable for such an installation  and consideration has not 
been given to the possibility of people with less than ideal common sense operating it. 

 

Have the existing chimney swept by a chimney sweep. Although you will be lining the chimney, any 

deposits left in the chimney will cause problems and may become a fire hazard.

 

Your attention is drawn to the precautions and responsibilities under the Health and Safety at Work Acts, 

and whatever new legislation being introduced during the life of this document.

Содержание Nestor Martin IN13

Страница 1: ...r Martin IN13 IN1208 Edition B June 2010 Euroheat Natural Energy Company This Manual Must Always be Available to the Stove Operator This manual must be used in conjunction with document IN1173 The Woo...

Страница 2: ...ed with a suitable fire resistant sealant we recommend Fraxfill available from Euroheat Part No MS9045 Some so called Heat Proof mastiks will only stand a temperature of 300 C before they start breaki...

Страница 3: ...istory will be recorded for reference in the future For the latest versions of manuals technical information accessories and spare parts visit the Euroheat web site Stoves Supplied Through Euroheat Au...

Страница 4: ...ative that all air passageways into out of and within the appliance are kept clean All permanent ventilation into the room provided for the stove must remain clear and unobstructed at all times Consid...

Страница 5: ...1 05 hr 82 8 Net 75 4 Gross Technical Data Continuous Operation Model Heat Output Wood Refuelling Interval Wood Energy Efficiency Wood Heat Output Smokeless Coal Refuelling Interval Smokeless Coal En...

Страница 6: ...rt number IN1208 Edition B 6 Supplied with the Stove Flue Spigot and Self adhesive Rope Stove Operating and Ash Pan Tool Approx 1 4m Self adhesive Rope Which may be used to form a seal between the sto...

Страница 7: ...d fire back should be removed The hearth and surrounding masonry work should be inspected for soundness and any remedial work undertaken if required The hearth should be level to give a stable base fo...

Страница 8: ...reach over three hundred degrees Celsius all materials used for constructing the housing must be both non combustible stable at high temperatures and insulate any part of the building which may be aff...

Страница 9: ...d single wall liners Weatherproof chimney pot and parged at a steep angle to disperse rain water Sound chimney brick work Stainless steel liner Flexible to single wall adapter if flexible liner is fit...

Страница 10: ...gain access to fit the flue spigot This baffle is held in place by two bolts and the baffle MUST be replaced once the flue has been connected There is a small lenth of self adhesive rope supplied with...

Страница 11: ...l never become excessively hot it will become very warm if the stove is kept burning at a high rate For this reason anything attached to the wall will also become very warm This may cause damage to oi...

Страница 12: ...gasses from the fuel If the air supply is abruptly and completely removed the fire will extinguish but the release of gasses will continue for some time These gasses will be above their ignition temp...

Страница 13: ...through the door To refit the replacement reverse the procedure Removal of the Upper Protection Plate The upper protection plate is held in place by the two side protection plates To remove 1 lift up...

Страница 14: ...that the lug on the bottom of the grate locates in the riddle arm Removal of the Grate Frame With the baffle plate log guard and side protection plates removed Lift out the two cast iron bottom prote...

Страница 15: ...pliances without prior notice We make every effort to ensure that the information provided in this document is correct and accurate at the time of printing Continued updates occur to adapt documents t...

Страница 16: ...491112 Technical 01885 491117 Reception 01885 491100 Need more info with over 10 000 pages of technical information spare parts product shots news and 1001 other things you will not find a more compr...