To switch on the AHU, the power plug must then be plugged in and the AHU must be switched on
using the ON / OFF switch on the rear (see
). After switching on, the green operating
lamp of the ON / OFF switch lights up.
Figure 14:
ON / OFF switch
Switch off
The AHU can be switched off by using the ON / OFF switch. During maintenance work or longer
breaks in operation the AHU must be disconnected from the power supply by using the power plug.
Timer switch
A timer switch installed on site can be used for a temporal control of the AHU (ATTENTION: Note
the switching capacity!).
7
Maintenance
EUROCLIMA AHUs are built mostly maintenance free and easy to maintain when required. The
maintenance intervals (see
) are indicative for normal operating conditions. Widely differing
applications may require different intervals, what must be checked in the individual case. The exe-
cution of the described checks and maintenance needs, see
chapter 7.5 (Maintenance plan)
, are
necessary to ensure a permanent safety operation and functionality of the AHU.
The entire AHU and all components must be checked regularly for pollution, corrosion, damage
and fixing and, if necessary, they must be cleaned or repaired.
Depending on the environmental conditions, it can lead to a superficial corrosion on components,
for example: motor, fan shafts, sheet metal cutting edges, etc. The resulting corrosion layer pro-
tects the underlying material from further corroding and does not represent a deficiency of the com-
ponent or the device. The removal of surface corrosion and treatment of the corresponding sites
are generally not required.
DANGER!
Danger due to electric shock
Before maintenance work, the AHU must be disconnected from the power by us-
ing the power plug. Indications of
chapter 2 (Safety instructions)
have to be ob-
served!
To order spare parts please contact your service partner.
EUROCLIMA recommends performing checks, maintenance, and repair work in compliance to the
specifications according to VDI 6022 sheet 1 and VDMA 24186 part 1.
Please note that EUROCLIMA is not responsible for damage caused by improper handling of sol-
vents and cleaning agents, and not liable for mechanical damage. Solvents and cleaning agents
may not contain alcohol for use on coated surfaces. EUROCLIMA recommends Allrain or Multirain
as cleaning agents and Sanosil or Sanirain from Hygan as disinfectants.
Содержание AirSanitizer
Страница 1: ...AirSanitizer INSTRUCTION MANUAL...
Страница 23: ...Instruction manual AirSanitizer 22 28 V12 20 0 9 Circuit diagram...
Страница 25: ...Instruction Manual AirSanitizer 24 28 V12 20 0 10 2 Declaration of conformity M Version...
Страница 27: ...Instruction Manual AirSanitizer 26 28 V12 20 0 11 2 Nameplate M Version Figure 17 Nameplate M Version...