EURO EPZ3WGCTS Скачать руководство пользователя страница 8

6) ELECTRICAL CONNECTION

The appliance is supplied with a 1800 mm long

flexible supply lead.

The point of attachment for this lead is located at

the rear and on the underside of the appliance

380 mm from the right hand side.

The voltage and power consumption are detailed

on the underside of the appliance. Ensure that the

appliance is correctly rated to the supply.

Connect appliance by way of a switched power

point.

THE APPLIANCE MUST BE EARTHED 

Ensure that this power point is properly earthed.

Look  at  the  connection  wiring  diagrams 

(fig. 12/B).

Warning: in order to avoid any hazard, any

electrical work performed on this equipment or

its associated wiring, should only be done by

persons authorised by the supplier or similarly

qualified persons.

The socket outlet for this hotplate shall be

installed near the hotplate and shall be easily

accessible.

The electrical connections of the appliance

must be carried out in compliance with the

provisions and standards in force.

Before connecting the appliance, check that:

- the voltage matches the value shown on the

specification plate and the section of the wires of

the electrical system can support the load, which

is also indicated on the specification plate.

- The electrical capacity of the mains supply and

current sockets suit the maximum power rating of

the appliance (consult the data label applied to the

underside of the hot plate).

- The socket or system has an efficient earth

connection in compliance with the provisions and

standards in force. The manufacturer declines all

responsibility for failing to comply with these

provisions.

When  the  appliance  is  connected  to  the

electricity main by a socket:

- Fit a standard plug suited to the load indicated on

the data label to the cable.

- Fit the wires following figure n.13, taking care of

respecting the following correspondences:

Letter L (live) = brown wire;

Letter N (neutral) = blue wire;

Earth symbol 

= green - yellow wire.

- The power supply cable must be positioned so

that  no  part  of  it  is  able  to  reach  an

overtemperature of 75 K.

- Never use reductions, adapters of shunts for

connection since these could create false contacts

and lead to dangerous overheating.

When the appliance is connected straight to the

electricity main:

- Install an omnipolar circuit-breaker between the

appliance and the electricity main. This circuit-

breaker should be sized according to the load

rating of the appliance and possess a minimum 3

mm gap between its contacts.

- Remember that the earth wire must not be

interrupted by the circuit-breaker.

-The electrical connection may also be protected by

a high sensitivity differential circuit- breaker.

You are strongly advised to fix the relative yellow-

green earth wire to an efficient earthing system.

Before performing any service on the electrical

part of the appliance, it must absolutely be

disconnected from the electrical network.

INSTALLATION

8

IMPORTANT:  the  appliance  must  be

installed following the manufacturer's

instructions. The manufacturer will not be

liable for injury to persons or animals or

property damage caused by an incorrect

installation.

If the installation requires modifications to

the home's electrical system or if the

socket is incompatible with the appliance's

plug,  have  changes  or  replacements

performed by professionally-qualified

person. In particular, this person must also

make sure that the section of the wires of

the  socket  is  suitable  for  the  power

absorbed by the appliance.

FIG. 13

FIG. 12/B

Содержание EPZ3WGCTS

Страница 1: ...atures on the products themselves If your cooktop requires service please contact your local customer service centre or your nearest Eurostyle agent listed at the back of this booklet COD 01099HM 11 0...

Страница 2: ...ob 10 Burner 2 control knob right 11 Burner 2 control knob left 15 Electric ignition button 16 Ultra rapid gas burner Wok 14 5 MJ 11 4 MJ 17 Trivet for ultra rapid burner 18 Burner 16 control knob Att...

Страница 3: ...hen the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Burners Power ratings Pan in cm Natural U LPG Ultra rapid or Wok 14 5 MJ 11 4 M...

Страница 4: ...ldren who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage resulting...

Страница 5: ...t force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MAINTENANCE To optimize the appearance a...

Страница 6: ...ll surface situated within 200 mm from the edge of any hob burner must be a suitable non combustible material for a height of 150 mm for the entire length of the hob Any combustible construction above...

Страница 7: ...t be used and all connections tested for gas leaks Natural Gas Natural Gas installations require the connection of a gas regulator at the appliance This regulator is supplied with the appliance on pur...

Страница 8: ...the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the following correspond...

Страница 9: ...ppliance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all gas they are male conical type Red...

Страница 10: ...the Only for use with U LPG label adhered to the bottom panel near the gas connection 9 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models 1 Remove...

Страница 11: ...on on the appliance instead of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or...

Страница 12: ...p is replaced to ensure a perfect tightness Greasing the taps see fig 17 18 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the ta...

Страница 13: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 19 and comply with the recommendations give...

Страница 14: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Страница 15: ...15...

Страница 16: ...16...

Отзывы: