Euro-Pro SC926H Скачать руководство пользователя страница 7

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

Fig. 1

Components

On/Off Switch: 

The unit is “On” when the 

switch is in the “Pushed down” position.  

The light on the On/Off switch will illuminate 

when the unit is on. The unit is “Off” when 

the switch is in its “Up” position.

Heating Light (red): 

This light will 

illuminate when the unit is heating up the 

water. 

Steam Ready Light (green): 

When this 

light is “On”, it indicates that the steam is 
ready to use.

CAUTION:

Read the instructions 

for “Filling or Re-Filling Your Steam 

Cleaner with Water” before opening the 
Safety Cap. 

CAUTION:

Always unplug before 

filling. 

ALLOW  UNIT TO COOL FOR 

FIFTEEN (15) MINUTES BEFORE 

REFILLING.

IMPORTANT:  

Do 

NOT

add cleaning 

solutions, scented perfumes, oils or any 

other chemicals to the boiler in this 

appliance. 

Use tap water or 

distilled/purified water if the tap water in 

your area is very hard.

Fig. 2

Assembly of Casters

The casters for your new steam cleaner 

are packed and shipped unassembled. 

To assemble the casters to the base of 

the steam cleaner, simply insert the 

caster stems onto one of the four (4) 

posts on the base and push downward 

with the palm of your hand. Repeat for 

the next three (3) casters.

Step 2:

Press the steam switch to the “Off” 

position, turn the unit off, unplug the 

unit from the electrical outlet and let 

the unit cool for 15 minutes.

Step 3:

Plug the power cord into an 

electrical outlet, assure that the 

On/Off switch is in the Off 

position and press 

the steam switch 

on the hand grip to 

the “ON” position to

vent any residual steam 

that is in the boiler. (Fig 1)

Step 4:

Remove the power cord from the 

electrical outlet and turn the steam 

switch on the hand grip to the “OFF” 

position. (Fig. 1)

Step 5:

Place the unit on a flat, stable 

surface. Slowly turn the safety 

filler cap counter clockwise until it is 

removed.

Step 6

: Insert the funnel 

into the tank 

opening and 

add 84 US Fl Oz 

(2.4L) of water. 

(Fig. 2) Place 

the funnel in 

the tank opening 

as illustrated in

Fig. 2. The 

funnel has been

specially 

designed to show 

when the water 

tank is full. When 

water starts to come out of the vent 

hole of the funnel, the tank is full. 

Remove the funnel slowly and let 

the remaining water in it go inside 

the water tank. 

Do Not Overfill

.

Step 7

: Replace the Safety Filler Cap.

Efficient Work

• For vertical surfaces, wipe with a 

towel from the top down, in this 

way the dirty water will not soil 

surfaces already cleaned.

Avoid changing brushes back and 

forth while cleaning.

Start with the smallest brush to 

clean tight spots and corners first.

Use a towel to wipe dirt as soon as 

possible, otherwise it will dry and 

re-adhere to the surface.

If you consistently use demineralized or 

distilled water, cleaning the tank is 

unnecessary.

Rinsing Out the Steam Cleaner

Normally, a periodic rinse of your steam 

cleaner will free it from deposits.  This is 

recommended every 10-15 tankfulls, to 

free up any scale deposits from the tank.

Fill the boiler with 20 oz. of water and 

shake the cleaner vigorously.  Tilt the 

cleaner upside down to empty the boiler of 

water and any scale deposits.

Descaling Your Steam Cleaner

If the tap water in you area contains a high 

level of calcium deposits and you have 

been using tap water to do your steam 

cleaning, you should descale your unit 

after 10-15 tankfulls.

Step 1:

Unplug the steam cleaner from 

the power source before you 

descale the boiler. Allow to cool.

Step 2:

Fill the boiler with 1 part  

vinegar and 5 parts water and 

leave overnight or for a period 

of approximately 8 hours.  Do 

not screw  the safety/filler cap 

onto the steam cleaner while 

you are descaling the boiler. 

Do not use the steam cleaner 

while descaling solution is 

inside the boiler.

Step 3:

After the period of soaking, turn 

the steam cleaner upside down 

to empty solution from the 

boiler.  Due to the fact that a 

small amount of solution will be 

left in the boiler, it is necessary 

to rinse the boiler out with clean 

water 2 or 3 times.  Your steam 

cleaner is now ready for use.

Note:

When storing your unit, always 

drain any residual water in the boiler and 

do not tighten the safety filler cap onto the 

unit. Always leave the safety filler cap 

loose on the unit when not in use.

To Descale the Steam Cleaner

Water

Use tap water for all your cleaning 

needs.

However, if you live in an area with 

hard water, use de-mineralized / 

distilled water when steaming light 

colored fabrics to eliminate the 

possibility of hard water stains.

IMPORTANT: 

Do 

NOT

add cleaning 

solutions, scented perfumes, oils or 

any other chemicals to the water used 

in this appliance. 

Use tap water or 

distilled/purified water if the tap 

water in your area is very hard.

Care and Maintenance

Filling or Re-filling Your Steam 

Cleaner With Water
IMPORTANT:

Always insure that the 

unit is “UNPLUGGED” from the wall 

receptacle prior to initial filling or re-filling 

the water tank and has been allowed to 

cool for 15 minutes. 

Never attempt to fill 

this unit under a water tap

always use 

the filling funnel provided.

WARNING:

Allow unit to cool for 

15 minutes before refilling

.  When 

refilling the steam cleaner while the boiler is 

still hot, 

there is a risk that water will squirt 

back during filling and cause scalding.  

Extreme care should be taken when 

refilling the unit. Use caution when 

opening the Safety/Filler Cap as cap may 

become hot during use and escaping 

steam can cause scalding.

Before Re-Filling:

Step 1:

Press the steam switch on the 

hand grip to the “On” position to

vent any remaining steam that is 

in the boiler.

8

5

Содержание SC926H

Страница 1: ...Professional Stainless Steel Steam Cleaner OWNER S MANUAL Model SC926H 120V 60 Hz 13 A 1550 W EURO PRO OPERATING LLC 94 Main Mill Street Door 16 Plattsburgh NY 12901 Tel 1 800 798 7398...

Страница 2: ......

Страница 3: ...hot water in the unit Never direct steam at any person The steam is very hot and can cause burns 10 Do not operate in the presence of explosive and or flammable fumes 11 This appliance is intended onl...

Страница 4: ...crannies Mold stains around door gaskets can be removed with the bristle brush To clean microwaves or other small appliances use the nylon bristle brush for small areas Note When cleaning small electr...

Страница 5: ...owel over the brush to remove excess moisture and residue Tip An old idea for polishing stainless steel is to wipe it down with seltzer soda water after it is cleaned Bathroom Areas To clean the batht...

Страница 6: ...ly rubbing a small area as far down on the back or other out of the way place on the furniture as possible If color comes off on the towel you may need to have the piece dry cleaned Window Glass Surfa...

Страница 7: ...e demineralized or distilled water cleaning the tank is unnecessary Rinsing Out the Steam Cleaner Normally a periodic rinse of your steam cleaner will free it from deposits This is recommended every 1...

Страница 8: ...t will transfer to the surface being cleaned ONLY USE LIQUID DETERGENTS never use dry detergents as many times the granules do not fully dissolve and become trapped in the towel This can scratch the s...

Отзывы: