3
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C DB / 19°C WB
Outdoor air temperature 35°C DB / 24°C WB
Heating: Indoor air temperature 20°C DB
Outdoor air temperature 7°C DB / 6°C WB
Power Source
380 – 400 V – 3N ~ 50 Hz
Voltage rating V 400
Control circuit 230 V ~ 50 Hz
Cooling Heating
Capacity
kW
BTU/h
Air circulation (High) m
3
/h 900
Moisture removal (High) Li/h —
Available voltage range V 342 to 418
Running amperes A 4.8 5.0
Power input W 2750 3000
Power factor
%
—
—
C.O.P. W/W 2.1 2.46
Compressor locked rotor amperes
A
28
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
ON / OFF 24-hours & Daily Program
Fan speeds
Indoor / Outdoor
3 and Auto / Auto (Hi, Lo)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter
Washable, Anti-Mold
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407c / 2400
Refrigerant control
Capillary tube
Operation sound
Indoor – Hi / Me / Lo
dB-A
50 / 47 / 44
Outdoor – Hi dB-A 55
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment
m
10
Refrigerant tube
Narrow tube
mm (in.)
6.35 (1/4)
diameter
Wide tube
mm (in.)
15.88 (5/8)
Refrigerant tube kit
Optional
Indoor Unit
Outdoor Unit
Unit dimensions
Height
mm
680
835
Width
mm
900
850
Depth
mm
190
305
Package dimensions Height mm 813 913
Width
mm
1,011
1,000
Depth mm 296 400
Weight
Net
kg
23.5
70.0
Shipping
kg
30.0
79.0
Shipping volume
m
3
0.24
0.37
Dimensions & Weight
Features
Electrical Rating
Performance
Indoor Unit FCR522HL
Outdoor Unit AER522SH3
5.70 7.40
3.0
19.500 25.200
Содержание AER518SH3
Страница 23: ...4 REFRIGERANT FLOW DIAGRAM Indoor Unit AWR518HL FCR518HL Outdoor Unit AER518SH3 20 ...
Страница 24: ...Indoor Unit AWR522HL FCR522HL Outdoor Unit AER522SH3 21 ...
Страница 46: ...Outdoor unit AER522SH3 43 ...
Страница 71: ...Printed in italy Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima it ...