EURGEEN OL-BKY26-A4 Скачать руководство пользователя страница 33

33 

 

6.2.

 

  CLEANING UP OF REFRIGERANT 

General Measures:   

1.

 

Gas/vapor heavier than air. May accumulate in confined spaces, 

particularly at or below ground level.   

2.

 

Eliminate every possible source of ignition.   

3.

 

Use appropriate personal protection equipment (PPE).   

4.

 

Evacuate unnecessary personnel, isolate, and ventilate area. 

5.

 

Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas. 

6.

 

Prevent entry to sewers and public waters. 

7.

 

Stop the source of the release, if safe to do so. Consider the use of water 

spray to disperse vapors.   

8.

 

Isolate the area until gas has dispersed. Ventilate and gas test area before 

entering. Contact competent authorities after a spill. 

 

 

Содержание OL-BKY26-A4

Страница 1: ...Local Portable Air Conditioner Owner s Manual Original instructions Model OL BKY26 A4 With R290 refrigerant READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...2 CONTENTS 1 BEFORE YOU BEGIN 03 2 FOR YOUR SAFETY 05 3 PRODUCT OVERVIEW 10 4 INSTALLATION 12 5 OPERATION 17 6 CLEANING AND CARE 23 7 TROUBLESHOOTING 25 8 DECOMMISSIONING 26...

Страница 3: ...tioner Outdoor Unit is limited The environmentally friendly R290 is used as the refrigerant R290 has no damaging influence on the ozone layer ODP a negligible greenhouse effect GWP and is available wo...

Страница 4: ...4 Service personnel are required to carefully read the USER MANUAL and SERVICE MANUAL before operation...

Страница 5: ...designated refrigerant The refrigerant loop is sealed Only a qualified technician should attempt to service Do not discharge the refrigerant into the atmosphere R 290 propane is flammable and heavier...

Страница 6: ...he units Component parts are designed for propane and non incentive and non sparking Component parts shall only be replaced with identical repair parts FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN...

Страница 7: ...te the unit from a power source of equal voltage frequency and rating as indicated on the product identification plate Always use a power outlet that is grounded Unplug the power cord when cleaning or...

Страница 8: ...r to clean other than those recommended by the manufacture The appliance shall be stored in a room without continuously operation sources for example open flames an operating gas appliance or an opera...

Страница 9: ...r competence to handle refrigerants safely in accordance with an industry recognized assessment specification WARNING Servicing shall only be performed as recommended by the equipment manufacturer Mai...

Страница 10: ...nance staff and others working in the local area shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the work space shall be sectioned...

Страница 11: ...l be displayed 2 2 7 Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work A degree of ventilation shall co...

Страница 12: ...s shall include initial safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfa...

Страница 13: ...13 The manufacture may provide other suitable example or may provide additional information about the refrigerant odour...

Страница 14: ...with air filter 7 Air inlet with air filter 2 Control panel with signal receptor 5 Air Exhaust 8 Drain opening with sealing plug 3 Air outlet with adjustable louver 6 Power cord box Note The appearanc...

Страница 15: ...to shut off when tank full Continuous drainage option 2 speed fan Casters for easy mobility Automatic restart in the event of power outage Auto defrosting function at low ambient temperatures Remote c...

Страница 16: ...16 Net Weight 26 0 kg Maximum Design Pressure HighSide 3 2MPa LowSide 0 7MPa Minimum Room Size 10 m2 Floor area Dimension 320 320 740mm Fuse type and rating T Type AC 250V 3 15A...

Страница 17: ...pack the carton and take the appliance and accessories out Check the device after unpacking for any damage or scratches on it Accessories 1 Exhaust hose 2 Hose connector 3 Window kit adapter 4 Remote...

Страница 18: ...for at least 24 hours before start up Never install the unit where it could be subject to Heat sources such as radiators heat registers stoves or other products that products that produce heat Direct...

Страница 19: ...re Do not replace or extend exhaust hose which will result in decreased efficiency even worse shut down the unit due to low backpressure Step 1 Connect the hose connector to one end of the exhaust hos...

Страница 20: ...the windows kit firmly in place secure the window kit with duct tape if required It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum effici...

Страница 21: ...21 Step7 Adjusting the length of the flexible exhaust hose and avoid bends in the hose Then place AC near an electrical outlet Step8 Adjust the louver at the air outlet and then switch on the unit...

Страница 22: ...22 5 Operation 5 1 Control Panel and Display 5 2 REMOTE CONTROL Fout Fout Fout Fout Fout Fout Fout Fout Fout Fout Fout...

Страница 23: ...23 Move the battery s insulating piece away before using Fan speed Power Add Minus Mode Timer Sleep...

Страница 24: ...etween HIGH blue and LOW blue 5 Sleep button Press to turn sleep mode on or off 6 Dehumidifyin g button Press to turn dehumidifying function on or off 7 Add button Increasing the desired temperature 1...

Страница 25: ...f COOL operation lights up Press ADD MINUS button to adjust the temperature which is displayed on the screen The temperature can be set between 16 and 32 Press SPEED button repeatedly until the desire...

Страница 26: ...ol and fan mode will be regulated depending on the room temperature and the target temperature Press MODE button repeatedly until the LED of smart operation lights up The unit starts with 23 target te...

Страница 27: ...e compressor will stop operating 10 minutes later or the coil temperature up to 7 the unit restart to cool operating mode B When the unit operates in the dehumidifying operating mode When the coil tem...

Страница 28: ...28 minutes and the power indicator blinking 5 4 5 Overload Protection In the event of a power loss to protect the compressor there is a 3 minute delay until the compressor restarting...

Страница 29: ...p it in safe area Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction Place the outlet of hose over a drain or bucket and ensure that water could freel...

Страница 30: ...30 degree of inclination should exceed 20 degrees Straighten the hose to avoid a trap existing in the hose...

Страница 31: ...an air filter or the evaporator may be contaminated 1 Clean the machine with a soft wet cloth 2 Pull out the louver on the front panel to gain access to the filter 3 Remove the filter mesh from the un...

Страница 32: ...32 Warning Do not touch the evaporator surface with bare hand or could cause injury of your fingers...

Страница 33: ...ection equipment PPE 4 Evacuate unnecessary personnel isolate and ventilate area 5 Do not get in eyes on skin or on clothing Do not breathe vapors or gas 6 Prevent entry to sewers and public waters 7...

Страница 34: ...mal Allowing for more time to cool down when the unit is first turned on Set temp level is higher lower than current Temperature Set the temperature at proper set point according the manual Water Leak...

Страница 35: ...ure sensor failure Check connection or replace it E2 Humidity sensor dampened or failure To clean or replace the temperature sensor Ft Condensate water high level alarm Empty the drain pan by remove t...

Страница 36: ...dry completely in a shaded area 4 Collect the power cord at the water tank 5 Re install the filter at its position 6 Preserving the machine in ventilating dry non corrosive gas and safe place indoor 7...

Страница 37: ...ities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the gro...

Страница 38: ...38 Firm Name Deals2day BV Web www deals2day be Address Hagenbroeksesteenweg 214C 2500 Lier Belgi Tel 32 3 284 35 84...

Страница 39: ...39 Version 2020 4 29...