141
AC characteristics
Parameter
Min.
Typ.
Max.
Units
Pulse rate
0
100
kHz
Turn-on time
5
µs
Turn-off time
5
µs
Typical switching performance @ 25°C
Current [mA]
Turn ON time [µs]
Turn OFF time [µs]
0.5
2.0
4.8
1.0
2.0
3.9
4.0
2.2
3.3
10
2.3
2.7
40
2.3
2.7
100
2.3
2.7
Isolation characteristics
Parameter
Value
Isolation grade
Functional
Max. DC voltage
250 V
Max. AC voltage
170 V
RMS
NOTE
The functional isolation is only for the circuit technical protection. It does
not provide an isolation that can protect a human being from electrical
shock!
Logical map
The state of the output port is determined as follows:
Logical State
Output port state
HIGH
The contact switch is closed (ON)
LOW
The contact switch is open (OFF)
Compatible loads
The following loads are compatible with the isolated contact output ports:
●
Any load within the 30 V / 100 mA envelope is accepted. The power originates from an
external power source or alternatively from the power delivered through the 12 V and GND
pins of the I/O connectors.
eGrabber