Thank you for purchasing the PreSonus EUREKA. PreSonus Audio Electronics 
has designed the EUREKA utilizing high-grade components to insure optimum 
performance for an infinite period of time.  We believe the EUREKA to be an 
exceptional sounding unit and an exceptional value. We encourage you to 
contact us at 1-800-750-0323 with any questions or comments you may have 
regarding your PreSonus equipment.  PreSonus Audio Electronics is committed 
to constant product improvement, and we value your suggestions highly.  We 
believe the best way to achieve our goal of constant product improvement is by 
listening to the real 

experts

, our valued customers.  We appreciate the support 

you have shown us through the purchase of this product.   

Please pay close attention to how you connect your EUREKA to your system. 
Improper grounding is the most common cause of noise problems found in studio 
or “live” sound environments.  We would like to suggest that you use this manual 
to familiarize yourself with the features, applications and correct connection 
procedure for your EUREKA before trying to hook it up to your system.  Thank 
you, once again, for buying our product and may we wish you Good Luck and 
enjoy your EUREKA! 

 

1 . 2   F E A T U R E S  

The following information is a summary of your EUREKA’s features: 

Microphone Pre-Amplifier.

   Your EUREKA contains a Class A discrete 

input buffer followed by a dual servo gain stage.  This arrangement results in 
ultra low noise and wide gain control allowing the EUREKA user to boost 
desirable signal without increasing unwanted background noise.   

 

48 Volt Phantom Power.

   The EUREKA has 48V Phantom power 

available. This assures optimum performance of your condenser 
microphones that require Phantom power and that the power supplied 
will be free of noise or distortion.  

 

Pad.

  A 20dB pad is available for reducing the in-coming signal level.  

This pad provides a more manageable signal from high output devices 
giving greater control over the in-coming signal and a much reduced 

Содержание - V 3.0

Страница 1: ...REKA M I C R O P H O N E P R E A M P L I F I E R C O M P R E S S O R P A R A M E T R I C E Q U A L I Z E R USER S MANUAL version 3 0 2003 2007 PreSonus Audio Electronics Incorporated All rights reserv...

Страница 2: ...laims for damage due to abuse neglect alteration or attempted repair by unauthorized personnel and is limited to failures arising during normal use that are due to defects in material or workmanship i...

Страница 3: ...1 Front Panel Basic Layout 7 2 2 Preamplifier 9 2 3 Compressor 10 2 4 Equalizer 12 2 5 Master 13 2 6 Back Panel 13 2 7 Power Supply 14 3 Operation 3 1 Microphones 15 3 2 Send and Return 15 3 3 192k 24...

Страница 4: ...udio or live sound environments We would like to suggest that you use this manual to familiarize yourself with the features applications and correct connection procedure for your EUREKA before trying...

Страница 5: ...of uneven performance often encountered with vacuum tube devices no tube to pick up RF or to age and become microphonic Variable Microphone Input Impedance This feature enables you to tune your micro...

Страница 6: ...hes the order of the signal chain putting EQ before the Compressor Master Section Gain Reduction to Meter Shows gain reduction on the meter implemented by the compressor Level The output of the EUREKA...

Страница 7: ...he front panel of the EUREKA is divided into four sections Preamplifier Compressor Equalizer and Master Preamplifier section Gain Control Impedance Control Saturation Control 48 Volt Switch 20db Pad P...

Страница 8: ...on Level Control Attack Release Ratio Threshold Gain Soft Knee Switch Bypass Switch Hi pass Sidechain Filter Equalizer Section 3 Band Parametric 80 Hz Filter Switch Bypass Switch Master Section Level...

Страница 9: ...ing amplified by the EUREKA The effect of manipulating the harmonic distortion is of increasing or decreasing the apparent warmth of the signal This feature is derived from manipulating the drain curr...

Страница 10: ...ter When pushed in the 80Hz button causes all frequencies below 80Hz to be attenuated dropped by 12dB This filter can be handy in live and studio applications For example the 80Hz filter can help to r...

Страница 11: ...o and Threshold settings of the compressor RELEASE Sets the length of time the compressor takes to return the Gain reduction back to zero no gain reduction Very short Release times can produce a very...

Страница 12: ...ects the center frequency of equalization If the gain is set to 0 this control will have no effect Q Bandwidth Controls the width of the frequency being adjusted Q is defined as the ratio of the cente...

Страница 13: ...er for the entire processing strip It is useful for adjusting the overall output level up or down to match the optimum input level of a recorder mixer etc GR TO METER When pushed the VU meter reads Ga...

Страница 14: ...ss devices such as reverbs delays de essers etc NOTE The LINE IN jack does not work unless the LINE button on the front of the unit is pushed in 2 7 P O W E R S U P P L Y The Power Jack on your EUREKA...

Страница 15: ...o select from 50 150 600 1500 and 2500 Refer to your microphone specifications to find the microphone output impedance and experiment with matching the Eureka s input impedance with the microphone s o...

Страница 16: ...d is available as an option for the PreSonus EUREKA It has AES EBU and SPDIF output connectors as well as an auxiliary TRS analog Line input connector The card has a selectable sample rate of 192kHz 9...

Страница 17: ...gs do not include the main preamplifier controls GAIN IMPEDANCE and SATURATE Set these preamplifier controls with the compressor and EQ in bypass for initial levels and tonal quality Use the 80Hz hi p...

Страница 18: ...ettings LOW MID HIGH EQ Comp Q Gain Freq Q Gain Freq Q Gain Freq Out n a 0 n a Nar 2 3k Wide 3 18 5k Nar Narrow Q 3 Electric Guitar Compressor settings Thresh Ratio Gain Soft Bypass Attack Release SC...

Страница 19: ...IGH EQ Comp Q Gain Freq Q Gain Freq Q Gain Freq Out Wide 6 85 MN 3 2 2k n a 0 n a MN Medium Narrow MW Medium Wide 5 Keyboards Compressor settings Thresh Ratio Gain Soft Bypass Attack Release SC HP 22...

Страница 20: ...ualizer settings LOW MID HIGH EQ Comp Q Gain Freq Q Gain Freq Q Gain Freq In Wide 8 60 Nar 8 400 Wide 6 2 5k 7 Snare Compressor settings Thresh Ratio Gain Soft Bypass Attack Release SC HP 22 6 4 In Ou...

Страница 21: ...verheads Compressor settings Thresh Ratio Gain Soft Bypass Attack Release SC HP 22 5 Fast Out Out Fast Med 400 Equalizer settings LOW MID HIGH EQ Comp Q Gain Freq Q Gain Freq Q Gain Freq Out Wide 4 40...

Страница 22: ...dance 1 Meg Ohm Send Connector 1 4 TRS Balanced Unbalanced Send Output Impedance 51 Ohms Return Connector 1 4 TRS Balanced Unbalanced Return Input Impedance 10K Ohms Metering 3 LED 20dBu 0dBu Clip Lin...

Страница 23: ...Impedance 51Ohms Metering Output level Analog VU 20dBu 6dBu Metering Gain reduction Analog VU 20dB 0dB Output Headroom 22dBu Physical Power Supply Internally Regulated Linear Type Power Requirements...

Отзывы: