![Eureka Jindara Duet SRS2/Duplicity Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/eureka/jindara-duet-srs2-duplicity/jindara-duet-srs2-duplicity_installation-instructions_2436047001.webp)
Hole cutting dimensions
Duet SRS2/Duplicity Through Wall Kit
(Part No. 214813)
Installation Instructions
1015mm
1015mm
Hearth
Internal wall
120mm
220mm
500mm
See
Note 1
• The installation of this appliance must be carried out as per this manual and the
manufacturer’s
We recommend that you use a
installer to carry out the installation.
• If in doubt do not hesitate to contact your local Jindara or Eureka dealer.
• This appliance weighs in excess of 230 kilograms. Extreme care should be taken when handling the appliance.
Read and follow these instructions (in conjunction with the Duet
SRS2/Duplicity Freestanding manual) carefully before installing this appliance.
SAVE THESE INSTRUCTIONS
A minimum 1000mm
wide x 1800mm
deep x 12mm thick
protector should
be used under and in
front of the appliance
when installing. The
protector should
extend 500mm in
front of the appliance
base on both doors.
Note 1: A combustible mantle must be no lower
than 500mm from top plate of heater.
Note 2: Internal wall noggin must not be lower
than 500mm above top plate of heater (a steel
noggin is permitted lower than 500mm).
If cutting hole through
a plasterboard wall
ensure wall width is
within 100mm
minimum to 115mm
maximum in thickness.
If constructed in brick
ensure wall width is
within 100mm
minimum to 145mm
maximum in thickness.
Sheet
1
of
4
GPN
214835
F:\Docs\Manuals\Heaters\GPN 214835 Thru Wall
m
m
0
0
5
m
m
0
0
5
1800mm
1000mm
Minimum
requirements
This Heater has been tested to AS2918:2001 Appendix B.
Test Report No. HCMG/14/069A using an Australian Standard
kit.
For the through wall installation additional
8˝ stainless is to be
over the 7˝ stainless active
then a 9˝ mesh
shield and a 10˝ stainless steel
shield are to be installed, both to ceiling height.
(See diagram opposite)
9˝ solid back
mesh
8˝ stainless
7˝ stainless
!
10˝ stainless steel
shield up to
drop box height
NB: First
height 4600 mm (+/– 300mm) from
protector
In
te
rn
al
w
al
l
120mm
min.
These must be used to make the installation conform.
Clearances to combustibles
400mm
1015mm
(cutout)
1015mm
(cutout)
See
Note 2
150mm
drop box
Triple skin
from
ceiling upwards