Installation Instructions

1015mm

1015mm

Hearth

Internal wall

120mm

220mm

500mm

See

Note 1

• The installation of this appliance must be carried out as per this manual and the 

 manufacturer’s 

We recommend that you use a 

 installer to carry out the installation.

• If in doubt do not hesitate to contact your local Jindara or Eureka dealer.

• This appliance weighs in excess of 230 kilograms. Extreme care should be taken when handling the appliance.

Read and follow these instructions (in conjunction with the Duet

SRS2/Duplicity Freestanding manual) carefully before installing this appliance.

SAVE THESE INSTRUCTIONS

A minimum 1000mm

wide x 1800mm

deep x 12mm thick

 protector should

be used under and in

front of the appliance

when installing. The

 protector should

extend 500mm in

front of the appliance

base on both doors.

Note 1: A combustible mantle must be no lower

than 500mm from top plate of heater.

Note 2: Internal wall noggin must not be lower

than 500mm above top plate of heater (a steel

noggin is permitted lower than 500mm).

If cutting hole through

a plasterboard wall

ensure wall width is

within 100mm

minimum to 115mm

maximum in thickness. 

If constructed in brick

ensure wall width is

within 100mm

minimum to 145mm

maximum in thickness.

Sheet

 1

 of

 4

   

GPN

 214835

F:\Docs\Manuals\Heaters\GPN 214835 Thru Wall     

m

m

0

0

5

m

m

0

0

5

1800mm

1000mm

Minimum 

 requirements

This Heater has been tested to AS2918:2001 Appendix B.

Test Report No. HCMG/14/069A using an Australian Standard

 kit. 

For the through wall installation additional  

8˝ stainless is to be 

 over the 7˝ stainless active

 then a 9˝ mesh 

 shield and a 10˝ stainless steel

 shield are to be installed, both to ceiling height. 

(See diagram opposite)

9˝ solid back

mesh

8˝ stainless

7˝ stainless

!

10˝ stainless steel

 shield up to

drop box height

NB: First 

 height 4600 mm (+/– 300mm) from 

 protector

In

te

rn

al

 w

al

l

120mm

min.

These must be used to make the installation conform.

Clearances to combustibles

400mm

1015mm

(cutout)

1015mm

(cutout)

See

Note 2

150mm

drop box

Triple skin 

 from

ceiling upwards

Содержание Jindara Duet SRS2/Duplicity

Страница 1: ...om top plate of heater Note 2 Internal wall noggin must not be lower than 500mm above top plate of heater a steel noggin is permitted lower than 500mm If cutting hole through a plasterboard wall ensure wall width is within 100mm minimum to 115mm maximum in thickness If constructed in brick ensure wall width is within 100mm minimum to 145mm maximum in thickness Sheet 1 of 4 GPN 214835 F Docs Manual...

Страница 2: ...s 3 4 as shown one on each side of heater 3 Reattach screws Fan switch Pedestal fascia panel goes on top of the lower fascia panels Lower fascia panel Panels should be flush with side of base 1 Fascia Assembly Inbuilt side 2 Fascia Assembly Freestanding side 3 Panel fascia lower left hand 4 Panel fascia lower right hand 5 Spray can 6 10 off 1 2 x 8G self tapping screws 7 4 springs 8 Panel heat def...

Страница 3: ...d the flue spigot lower the top of the heater and continue to slide the Freestanding Fascia Assembly until it meets the Inbuilt Fascia Assembly Step 6 1 Overlap the flanges as shown 2 Attach the springs between Inbuilt Fascia Assembly and Freestanding Fascia Assembly on both sides of the heater 3 Attach heat deflector to freestanding fascia assembly with self tapping screws C D Square Flue Spigot ...

Страница 4: ... in the interests of product improvement Any enquiries contact the dealer from whom you purchased your heater PLEASE COMPLETE Dealer name Dealer Address Phone Number Please attach your original purchase dockets to this instruction book for future reference F Docs Manuals Heaters HM214835 Duet In Wall Inst through Windows NT Explorer Heating ...

Отзывы: