4. Install the cover back on the system, and make sure to
align the knob and the hole on the cover. Keep the inlet and
outlet hose free from stress.
5. Inset the Regeneration (Regen.) knob back to the knob axis in the proper direction, and turn
the knob to Service (Ser.) position, close the slide cover completely. The system is now on
standby for use. (NOTE: Knob position based on the direction indicated by tiny outshoot of
the knob.)
Note: For first use after the installation of system, it is recommended to turn ON the shower
and keep the water flowing for 2-3 minutes, in order to clean up the plumbing and fittings.
Usage and Maintenance
1
.
Service
Regeneration button on Service mode, can provide softened water by shower for customer use.
Note: Under service mode, water flows from the shower and the system will refill
automatically until it is finished and maintains the brine level.
2. Regeneration
Once the hardness of output water increases, it means Aquasoft ion exchange resin is
exhausting and system needs regeneration. Ensure that Aquasoft Salt tank contains
sufficient quantity of regeneration. Spin the knob to the Regeneration position, and put the
shower in the bathtub or entrance of the floor drain, turn on the shower and make the brine
flow out from shower for around 30 min. When finished, turn OFF the shower and turn back
to Service position, then turn on the shower again, rinse for 1-2 min. to drain the remnant
regenerating brine.
Note: Regenerating salt is made up of
food-grade salts, and will not harm you.
non-iodized
3
.
Add Salt
The system needs salts to regenerate its capacity. Please check the salt storage in time
during usage and keep unmelted salt in the brine tank. Open the system’s slide and put salt
into the tank equably. It is recommended you add 3-4 kg salt in each exhausted cycle.
4. Maintenance
Needs no special maintenance under normal usage. If the system is
not used for more than a week, it is recommended to rinse the
system for 1-2 min. before usage, to ensure you get high quality
fresh soft water.
6