![Eureka Forbes Aquaguard Select Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/eureka-forbes/aquaguard-select/aquaguard-select_user-manual_2436106022.webp)
Your Aquaguard
®
Select is equipped with a unique pump which has both suction and boosting capabilities, and comes
with specifically designed DRS (Dry Run Sensor). Now, this enables your Aquaguard
®
Select to work in the following
operating conditions:
• Normal Input Water Pressure – up to 3 bar (max.)
• Low Water Pressure from Loft Tank
• Zero Water Pressure
• Suction Mode: Maximum 3 feet below product level
Product Functioning at ‘Normal/Low and Zero Water Pressure’:
• Ensure that the water flow from the tap into the product is always more than 1.5 LPM.
• In case there is no incoming water supply, the DRS detects unavailability of water and stops the unit from working to
prevent dry running.
• As and when the water supply resumes, the DRS detects the availability of water and restarts the product. Meanwhile, the
intelligent mechanism in your Aquauard
®
Select will keep on checking the availability of water at regular defined intervals
and makes the product work when water supply resumes.
Note:
In case you notice that water in the supply line resumes and product is in standby mode, then please restart the product
by switching the power supply OFF and ON again.
Product Functioning with ‘Suction Capability’:
•
The
ZPP
in your Aquauard
®
Select also has the capability of suction of water from a 3 feet distance below the level of product i.e. it can pull water from a
bucket/container.
•
Note:
Water suction from underground storage tank, pump, open well, etc. where the water level is beyond 3 feet below the level of product is not
suitable.
• Whenever the water in the container/bucket is emptied, the DRS detects non-availability of water and stops the product from functioning.
•
Note:
When the container/bucket is refilled with water, the product should be restarted by switching the power supply OFF and ON again.
• Prolonged use in loft tank mode /suction mode can impact the working of pump, performance of product and life of filters. If the performance is not
meeting the expectation of the consumer due to low pressure, then use of a booster pump is recommended.
• Do not re-circulate/reuse the rejected water (discharged by the product) back into the product.