Euramco Safety UB20 Series Скачать руководство пользователя страница 2

 

WARNING!  

These units are intended for Explosive Atmospheres use in accordance 
with ATEX Directive 94/9/EC. It is the user’s responsibility to determine 

the suitability of this equipment for the intended purpose 

 

CAUTION! THESE FANS ARE NOT INTENDED FOR USE IN MINES 
SUSCEPTIBLE TO FIREDAMP. 

 

Explosion Proof Fan Rated: Ex d e IIB T6 

Euramco Safety hereby declares that the equipment listed in this 
manual conforms to the relevant Essential Health and Safety 
Requirements of the European Machinery Directive and standards listed 
below. 

 

Council of European Communities Directives: 

89/392/EEC as amended by 91/368/EEC and 93/44/EEC.         
Also EC Directives 93/68/EECI, 94/9/EC, and 76/117/EEC.

 

 

Standards to which conformity is declared: 

See Declaration of Conformity (last page). 

 

Category, Group and Zone Classifications 

* According to ATEX Directive (94/9/EC)          

 

 

 

 

 

T6 Temperature Classification 

* According to EN 60079-0:2006 
  85°C T6 

 

To ensure that there is no risk of ignition due to hot surfaces, the 

equipment is classified with regard to the maximum surface 
temperature of any part of the equipment while in operation based on 
the ambient temperature of 40°C. Equipment must be selected with a 
suitable temperature classification for the gases and vapors present 
where the equipment is to be installed. Ensure that the maximum 

surface temperature of any parts of the equipment are below the 
ignition temperature of the explosive atmosphere concerned.  
This equipment is intended for use in ambient temperatures ranging 
between -20°C and +40°C. 

 

Classification: Ex de 

* According to EN 60079-1:2004 
Flame Proof Enclosures with Increased Safety Components. 

 

Description of Apparatus

 

The Portable Ventilator assemblies represented herein consist of an 
Approved Explosion Proof Electric Motor Rated: 

Ex d IIB 

by Bluffton 

Motor Works (Formerly Franklin Electric) as listed below and are 
covered by Certificate No. DEMKO 03 ATEX134885U. 

 
  EURAMCO SAFETY VENTILATOR                        

 

BLUFFTON MOTOR

 

MODEL # 

INPUT VOLTAGE 

EURAMCO PART # 

BLUFFTON PART # 

IMPELLER 

UB20xx 

115VAC, 60Hz 

EF7002XX 

1933007415 

PLASTIC 

UB20xx 

230VAC, 50/60Hz 

EF8002XX 

1933007419 

PLASTIC 

EFi75xx 

115/230VAC, 50/60Hz 

EB7201XX 
EB7201XX-230 

1133007405 

METAL 

EFi85xx 

115/230VAC, 50Hz 

EB8201XX 

EB8201XX-110 

1223007401 

METAL 

EFi120xx 

115/230VAC, 50Hz 

EA8120XX 
EA8120XX-110 

1223007401 

METAL 

EFi150xx 

115/230VAC, 50/60Hz 

EG8200XX 

EG8200XX-230 

1133007417 

METAL 

The Flame Proof Electric Motor 

Power Requirements: See chart above. 

Ambient Temperature Range:

 -20°C<T

amb

< +40°C 

 

Ingress Protection to IEC 529:

 IP55 

 

Marked: (“Bluffton Motor Works”) Electric Motor for Hazardous 
Locations  

Flame Proof Enclosure:

 Ex d IIB 

 

The electric motor consists of one flameproof enclosure, which contains 
less than 6% magnesium by weight. The on/off switch is housed within 
the motor enclosure, and is operated by a shaft, extending out from the 
rear end bell to a lever. The lever is accessible via an attached push 
rod. 

 

Motor connections are made through a non-detachable cable, secured 
to the motor with an approved Flame Proof cable gland from the 

company Hawke, Model 501/421/0/M20 and complies with International 
Standards EN 60079-0:2006, EN 60079-1:2004, EN 60079-7:2007.  

 

The electric motor drives an aluminum or plastic fan blade containing 
less than 6% Magnesium by weight which is enclosed in a plastic, 
statically conductive housing with a conductivity rating of <1 giga-
ohmes. Connection to the motor is facilitated by a Terminal Block 

mounted in an Increased Safety/Flame Proof Enclosure rated II 2 G Ex 
e II T6, from the company Rose Industries, Part No. 05080806, and 
covered under the certificate No. PTB 00ATEX1063. This box was 
designed to conform to International Standards EN 60079-0:2006, EN 
60079-1:2004, EN 60079-7:2006, EN 61241-0:2004 and EN 61241-
1:2004. The enclosure features stainless steel grounding lugs, with a 

high heat silicon gasket. 

 

The Flame Proof enclosure has attached, approved, explosion proof 
cable glands 

Rated:

 IIGD Ex e II 

 

Type:

 Polyamide Ex metric conforms to International Standards EN 

60079-0:2006, EN 60079-7:2006, EN 61241-0:2006 and EN 61241-
1:2004. 

Material:

 Polyamide  

Color:

 Black/Blue 

Grommet:

 NBR 

Protection classification:

 IP68 

Temperature range:

 -4°F to +212°F 

Approval:

 PTB 00 ATEX 1063 

 

The power cable from each blower is terminated with either a yellow 
120VAC or a Blue 240VAC Explosion-proof plug to match the operating 

voltage of the motor. The plugs are made by Appleton and complies 
with International Standards: EN 60079-0:2006, EN 60079-1:2004, EN 
61241-0:2004, EN 61241-1:2004 & EN 60079-7:2006. 
 
The fans are assembled with both Inlet and Outlet Safety Guards that 

conform to the safety standards to prevent danger zones being reached 
by upper limbs in the BS EN 294:1992 
Guards Standard. 

 
 
 
 
 
 

II 2 G Ex d e IIB T6 
CE 0539 
Demko 09 ATEX 0926969 

 

TECHNICAL INFORMATION & INSTALLATION INSTRUCTIONS 

SM-EFATEX Rev C 

 

Отзывы: