C. Shell scratch or breakage after leaving the factory.
D. Wiring scratch or breakage.
E. Malfunction or damage caused by the force majored (fire, earthquake etc. )
or natural disasters (lightening etc.)
F. Beyond Warranty period.
7. Error code definition table
error code
definition
2
Over current protection is checked by the controller. Check
whether the connectors of three-phase power cable and the hall
signal connectors are badly connected. There is something wrong
with the controller or motor if the problem is still present after
reconnect the connectors.
3
The controller can’t properly drive the motor: Check whether
the connectors of three-phase power cable and the hall signal and
the power supply connectors are badly connected. Or there is not
enough power to drive the system than 2S, such as climbing or the
wheel is stuck . There is something wrong with the controller or
motor if the problem is still present after reconnect the
connectors.