Operating Instructions

Safety Switch NZ.R...EX 

Function test

 WARNING

Fatal injury due to faults during the function test.

 

f

Before carrying out the function test, make sure 

that there are no persons in the danger zone.

 

f

Observe the valid accident prevention regula-

tions.

Check the device for correct function after installa-

tion and after every fault.
Proceed as follows:

Mechanical function test

The actuating element must move easily. Close the 

guard several times to check the function.

Electrical function test

1.  Switch on operating voltage.
2.  Close all guards.

 

¨

The machine must not start automatically.

3.  Start the machine function.
4.  Open the guard.

 

¨

The machine must switch off and it must not be 

possible to start it as long as the guard is open.

Repeat steps 2 - 4 for each guard.

Inspection and service

 WARNING

Danger of severe injuries due to the loss of the 

safety function.

 

f

If damage or wear is found, the complete switch 

must be replaced. Replacement of individual 

parts or assemblies is not permitted.

 

f

Check the device for proper function at regular 

intervals and after every fault. For informa-

tion about possible time intervals, refer to 

EN ISO 14119:2013, section 8.2.

 

f

Do not open, service or repair in an area in which 

an explosive atmosphere may be present.

 

f

Switches and actuators must be regularly freed 

of dirt and cleaned.

 

f

Avoid electrostatic charging – clean only with 

a damp cloth!

Inspection of the following is necessary to ensure 

trouble-free long-term operation:

 

f

correct switching function

 

f

secure mounting of all components

 

f

damage, heavy contamination, dirt and wear

 

f

sealing of cable entry

 

f

loose cable connections or plug connectors.

Info

: The year of manufacture can be seen in the 

bottom, right corner of the type label.

Exclusion of liability and warranty

In case of failure to comply with the conditions for 

correct use stated above, or if the safety regula-

tions are not followed, or if any servicing is not 

performed as required, liability will be excluded and 

the warranty void.

EU declaration of conformity

The declaration of conformity is part of the operating 

instructions, and it is included as a separate sheet 

with the device. 
The original EU declaration of conformity can also 

be found at: www.euchner.com

Technical data

Parameter

Value

Housing material

Anodized die-cast alloy

Degree of protection

IP67

Mechanical life

30x10

6

 operating cycles

Ambient temperature

-20 ... +75 °C

Installation orientation

Any

Approach speed, max.,  

with actuator RS

20 m/min

Approach speed, min.

0.1 m/min

Actuating force at 20 °C

30 N

Actuation frequency, max.

7,000/h

Connection

Cable gland M20x1.5 

(included)

Clamping range for the 

cable gland

6.5 ... 12 mm

Conductor cross-section

(rigid/flexible)

0.34 ... 1.5 mm

2

Rated insulation voltage

U

i

 = 50 V

Rated impulse withstand voltage

U

imp

 = 2.5 kV

Conditional short-circuit current

100 A

Degree of contamination

(external, acc. to EN 60947-1)

3 (industrial)

Rated data for the switching elements

ES528H/ES538H

SK2121H/SK2131H/SK3131H

Switching principle of switching element

Slow-action switching contact

Slow-action switching contact

Contact material

Silver alloy, gold flashed

Silver alloy, gold flashed

Switching voltage, min.,  

at 10 mA

12 V

12 V

Utilization category  

acc. to IEC 60947-5-1

AC-15  4 A 50 V

DC-13  4 A 24 V

AC-15  4 A 50 V

DC-13  6 A 24 V

Switching current, min.,

1 mA

10 mA

1 mA

10 mA

at switching voltage

DC 24 V

DC 12 V

DC 24 V

DC 12 V

Convent. thermal current I

th

4 A

4 A

Short circuit protection (control  

circuit fuse) acc. to IEC 60269-1

4 A gG

4 A gG

Reliability values acc. to EN ISO 13849‑1
depending on the switching current at 24 V DC

At DC-13  100 mA/24 V

≤ 0.1 A

B

10D

ES528H/ES538H

2 x 10

7

SK2121H/SK2131H/SK3131H

2 x 10

7

ATEX rating

 

  II3G Ex nR IIB T5 Gc X

   

II3D Ex tc IIIC T100°C Dc

Service

If servicing is required, please contact:
EUCHNER GmbH + Co. KG

Kohlhammerstraße 16

70771 Leinfelden-Echterdingen

Germany

Service telephone

:

+49 711 7597-500

E‑mail

:

[email protected]

Internet

:

www.euchner.com

Содержание NZ R EX Series

Страница 1: ...iene Das Schutzblech leitfähiger ESD Schutzlack muss als Schlagschutz unbedingt montiert werden Innerhalb der vorgegebenen Betriebstemperatur ist nicht davon auszugehen dass die explosionsfähige Atmosphäre in das Gehäuse hineingezogen wird Montage WARNUNG Explosionsgefahr durch unsachgemäße Montage und Verwendung f Schalter nicht in einer Atmosphäre mit Brenngasen verwenden wie Schwefelkohlenstoff...

Страница 2: ...ypschilds ersichtlich Haftungsausschluss und Gewährleistung Wenn die o g Bedingungen für den bestimmungsge mäßen Gebrauch nicht eingehalten werden oder wenn die Sicherheitshinweise nicht befolgt werden oder wenn etwaige Wartungsarbeiten nicht wie gefordert durchgeführt werden führt dies zu einem Haftungs ausschluss und dem Verlust der Gewährleistung EU Konformitätserklärung Die Konformitätserkläru...

Страница 3: ... 13 42 34 22 14 SK3131H 13 14 21 22 11 12 21 22 ES528H ES538H 0 1 2 3 4 6 mm mm 6 4 3 2 1 0 SK2121H 41 42 31 32 21 22 11 12 6 4 3 2 1 0 mm 2 5 SK2131H 41 42 33 34 21 22 11 12 6 4 3 2 1 0 41 42 33 34 21 22 13 14 SK3131H mm 0 1 2 3 4 6 mm 2 5 3 0 ma x 6 1 RS Stahlrolle Endstellung Ruhestellung Nocken Bild 4 Maßzeichnung NZ1 EX 7 3 5 3 5 3 30 0 1 40 0 1 R6 44 74 97 60 0 1 44 0 1 50 1 44 0 1 30 max 42...

Страница 4: ... protective paint as shock protection Within the stipulated operating temperature it is not to be expected that the explosive atmosphere will be drawn into the housing Mounting WARNING Danger of explosion due to improper mounting and use f Do not operate the switch in an atmosphere containing combustible gases such as Carbon disulfide Carbon monoxide Ethylene oxide f Protection of the switch and a...

Страница 5: ... safety regula tions are not followed or if any servicing is not performed as required liability will be excluded and the warranty void EU declaration of conformity The declaration of conformity is part of the operating instructions and it is included as a separate sheet with the device The original EU declaration of conformity can also be found at www euchner com Technical data Parameter Value Ho...

Страница 6: ... 22 12 SK2131H 41 33 21 11 42 34 22 12 41 33 21 13 42 34 22 14 SK3131H 13 14 21 22 11 12 21 22 ES528H ES538H 0 1 2 3 4 6 mm mm 6 4 3 2 1 0 SK2121H 41 42 31 32 21 22 11 12 6 4 3 2 1 0 mm 2 5 SK2131H 41 42 33 34 21 22 11 12 6 4 3 2 1 0 41 42 33 34 21 22 13 14 SK3131H mm 0 1 2 3 4 6 mm 2 5 3 0 ma x 6 1 RS Steel roller End position Free position Dog Fig 4 Dimension drawing for NZ1 EX 7 3 5 3 5 3 30 0 ...

Отзывы: