Correct use

Safety switches series NZ are interlocking devices 

without guard locking (with safety function). The 

actuator is uncoded (e.g. dog). In combination with 

a movable safety guard and the machine control, 

this safety component prevents dangerous machine 

functions from occurring while the safety guard is 

open. A stop command is triggered if the safety 

guard is opened during the dangerous machine 

function.
This means:

 

f

Starting commands that cause a dangerous ma-

chine function must become active only when the 

safety guard is closed.

 

f

Opening the safety guard triggers a stop com-

mand.

 

f

Closing a safety guard must not cause automatic 

starting of a dangerous machine function. A 

separate start command must be issued. For 

exceptions, refer to EN  ISO  12100 or relevant 

C-standards.

Devices from this series can be used as safe position 

encoders.
Before the device is used, a risk assessment must 

be performed on the machine, e.g. in accordance 

with the following standards:

 

f

EN ISO 13849-1, Safety of machinery – Safety-re-

lated parts of control systems – Part 1: General 

principles for design

 

f

EN  ISO  12100, Safety of machinery – General 

principles for design – Risk assessment and risk 

reduction

 

f

IEC  62061, Safety of machinery – Functional 

safety of safety-related electrical, electronic and 

programmable electronic control systems

Correct use includes observing the relevant require-

ments for installation and operation, particularly 

based on the following standards:

 

f

EN ISO 13849-1, Safety of machinery – Safety-re-

lated parts of control systems – Part 1: General 

principles for design

 

f

EN ISO 14119, Safety of machinery – Interlocking 

devices associated with guards – Principles for 

design and selection

 

f

EN  60204-1, Safety of machinery – Electrical 

equipment of machines.

Important!

 

f

The user is responsible for the proper integration 

of the device into a safe overall system. For this 

purpose, the overall system must be validated, 

e.g. in accordance with EN ISO 13849-2.

 

f

If the simplified method according to section 6.3 

of EN ISO 13849-1:2008 is used for determining 

the Performance Level (PL), the PL might be re-

duced if several devices are connected in series.

 

f

Logical series connection of safe contacts is 

possible up to PL  d in certain circumstances. 

More information about this is available in 

ISO TR 24119.

 

f

If a product data sheet is included with the prod-

uct, the information on the data sheet applies 

in case of discrepancies with the operating 

instructions.

Safety precautions

 WARNING

Danger to life due to improper installation or due 

to bypassing (tampering). Safety components 

perform a personal protection function.

 

f

Safety components must not be bypassed, 

turned away, removed or otherwise rendered 

ineffective. On this topic pay attention in partic-

ular to the measures for reducing the possibility 

of bypassing according to EN ISO 14119:2013, 

section 7.

 

f

Mounting, electrical connection and setup only 

by authorized personnel possessing special 

knowledge about handling safety components.

Function

Precision single limit switches are used for posi-

tioning and control applications in mechanical and 

systems engineering. 
The switching element is actuated via a lever arm. 

See travel diagram (see Figure 5).

Switching states

The detailed switching states for your switch can be 

found in Figure 5. All available switching elements 

are described there.

Mounting

NOTICE

Device damage due to improper mounting and 

unsuitable ambient conditions.

 

f

Safety switches and actuators must not be used 

as an end stop.

 

f

Observe EN ISO 14119:2013, sections 5.2 and 

5.3, for information about fastening the safety 

switch and the actuator.

 

f

Observe EN  ISO  14119:2013, section 7, for 

information about reducing the possibilities for 

bypassing an interlocking device.

 

f

Protect the switch head against damage.

 

f

The actuator (lever arm) must be positively mount-

ed to the actuating shaft. The polygon drives on 

the actuator and actuating shaft must engage 

with each other (see Figure 2).

 

f

To ensure correct operation, the trip dogs must 

be fitted so that the actuator is deflected by at 

least an angle of 

45°

+5°

 (achievement of the 

stipulated contact opening, see Figure 8 and 

Figure 9).

Important!

 

f

To prevent the actuating element from bouncing, 

the dog must run out gradually (see Figure 1).

α

α

α

Figure 1:  Dog shape

Adjustment options

Vertical actuator adjustment 4 x 90°/8 x 45° 

(positive mounting)

Example:

Figure 2:  Vertical actuator adjustment

Horizontal adjustment 4 x 90°

Figure 3:  Horizontal adjustment

1.  Remove the screws from the actuating head.
2.  Set the required direction.
3.  Tighten the screws with a torque of 1.2 Nm.

Switching direction change with lever arm 

actuation

  Left/right switching  Right switching 

Left switching

  

 

 

(default setting)

Figure 4:  Changing the switching direction

Electrical connection

 WARNING

Loss of the safety function due to incorrect 

connection.

 

f

Use only safe contacts ( ) for safety functions.

Use of the safety switch as an interlocking 

device for personnel protection

At least one contact   must be used. This signals 

the position of the safety guard (for terminal assign-

ment, see Figure 7).

The following information applies to devices 

with plug connector:

 

f

Check that the plug connector is sealed.

The following information applies to devices 

with cable entry:

1.  Use a suitable tool to open the desired inser-

tion opening.

2.  Fit the cable gland with the appropriate degree 

of protection.

3.  Connect and tighten the terminals with 0.5 Nm 

(1 Nm on ES511) (for terminal assignment, 

see Figure 7).

4.  Check that the cable entry is sealed.
5.  Close the switch cover and screw in place 

(tightening torque 1.2 Nm).

Function test

 WARNING

Fatal injury due to faults during the function test.

 

f

Before carrying out the function test, make sure 

that there are no persons in the danger area.

 

f

Observe the valid accident prevention regula-

tions.

Check the device for correct function after installa-

tion and after every fault.
Proceed as follows:

Mechanical function test

The actuating element must move easily. Close the 

safety guard several times to check the function.

Electrical function test

1.  Switch on operating voltage.
2.  Close all safety guards.

¨

¨

The machine must not start automatically.

3.  Start the machine function.
4.  Open the safety guard.

¨

¨

The machine must switch off and it must not be 

possible to start it as long as the safety guard 

is open.

Repeat steps 2 - 4 for each safety guard.

Содержание NZ H Series

Страница 1: ...rtes Fachperso nal welches über spezielle Kenntnisse im Umgang mit Sicherheitsbauteilen verfügt Funktion Präzisions Einzelgrenztaster werden zum Positio nieren und Steuern im Maschinen und Anlagenbau eingesetzt Das Schaltelement wird über einen Schwenkhebel betätigt Siehe Schaltwegdiagramm siehe Bild 5 Schaltzustände Die detaillierten Schaltzustände für Ihren Schalter finden Sie in Bild 5 Dort sin...

Страница 2: ...fgeführten Richtlinie n ist und dass die jeweiligen Normen zur Anwendung gelangt sind EUCHNER GmbH Co KG Kohlhammerstr 16 D 70771 Leinfelden Echterdingen Angewendete Richtlinien f f Maschinenrichtlinie 2006 42 EG Angewendete Normen f f EN 60947 5 1 2004 Cor 2005 A1 2009 f f EN 1088 1995 A2 2008 f f EN 14119 2013 Die originale EG Konformitätserklärung finden Sie auch unter www euchner de Service We...

Страница 3: ...inder SVM5 Pinbelegung Stiftdose Ansicht auf Geräteseite 4 3 1 2 Kontaktbelegung Schaltelemente Kontaktbelegung Schaltelemente Kontaktbelegung Schaltelemente 3 1 4 2 13 21 14 22 5 6 3 1 4 2 13 21 14 22 3 1 4 2 11 21 12 22 5 6 3 1 4 2 11 21 12 22 ES 511 ES 528H ES 538H mit LED Anzeige 7 5 3 1 8 6 4 2 41 31 21 11 42 32 22 12 7 5 3 1 8 6 4 2 41 33 21 11 42 34 22 12 SK2121H SK2131H 3 1 4 2 13 21 14 22...

Страница 4: ...si tioning and control applications in mechanical and systems engineering The switching element is actuated via a lever arm See travel diagram see Figure 5 Switching states The detailed switching states for your switch can be found in Figure 5 All available switching elements are described there Mounting NOTICE Device damage due to improper mounting and unsuitable ambient conditions f f Safety swi...

Страница 5: ...EC declaration of conformity can also be found at www euchner de Service If service support is required please contact EUCHNER GmbH Co KG Kohlhammerstraße 16 D 70771 Leinfelden Echterdingen Service telephone 49 711 7597 500 Fax 49 711 753316 E mail support euchner de Internet www euchner de Technical data Parameter Value Housing material Anodized die cast alloy NZ1 cable entry NZ2 plug connector M...

Страница 6: ...ctor SVM5 Pin assignment for male socket view of device side 4 3 1 2 Terminal assignment for switching elements Terminal assignment for switching elements Terminal assignment for switching elements 3 1 4 2 13 21 14 22 5 6 3 1 4 2 13 21 14 22 3 1 4 2 11 21 12 22 5 6 3 1 4 2 11 21 12 22 ES 511 ES 528H ES 538H with LED indicator 7 5 3 1 8 6 4 2 41 31 21 11 42 32 22 12 7 5 3 1 8 6 4 2 41 33 21 11 42 3...

Отзывы: