![EUCHNER ESM-CB Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/euchner/esm-cb/esm-cb_operating-instructions-manual_2434768013.webp)
13
2522722-01-05/19 (Translation of the original operating instructions)
Operating Instructions
Safety Relay with IO-Link ESM-CB
EN
8.1.
Terminal assignment
DIA
PWR
STATE1
STATE2
K1/K2
IO-Link
24
L-
L+
C/Q
ID/C
S10
S11
A1 A2 S21
S14
S34
S32
S12
23
14
13
ESM-
CB
OM
OM
A1
Power supply 24 V DC
A2
Power supply 0 V
S10
Supply input for S14
S11
Supply output for S12 and S21
S12
Sensor circuit S1 input (channel 1)
S14
Sensor circuit S1 input (channel 2)
S21
Input for start circuit
S32
OSSD sensor circuit S2 input (channel 1), input for FO1A from BR series connection
S34
OSSD sensor circuit S2 input (channel 2), input for FO1B from BR series connection
PWR
Power LED (green, yellow, red)
DIA
Diagnostic message present indication; LED (red)
IO-Link
IO-Link communication status indication; LED (green)
STATE 1
Sensor circuit S1 status indication; LED (green)
STATE 2
Sensor circuit S2 status indication; LED (green)
K1/K2
Safety circuit K1 and K2 status indication; LED (green)
13/14
Safety contact, non-time-delay
23/24
Safety contact, non-time-delay
ID/C
Safety switch diagnostic input
OM
Digital monitoring output
C/Q
IO-Link switching and communication line
L+/L-
IO-Link supply