Operating Instructions
Transponder-Coded Safety Switch CTP-LBI-AP
18
(translation of the original operating instructions) 2136918-04-05/19
10.6. Connection CTP-AP
Connect the device as shown in
. The monitoring outputs can be routed to a control system.
On devices with RST input the following applies
: The switches can be reset via the RST input. To do this, a voltage of
24 V is applied to the RST input for at least 3 s. The RST input must be connected to 0 V if it is not used.
WARNING
If there is a mistake, loss of the safety function due to incorrect connection.
Ì
To ensure safety, both safety outputs (FO1A and FO1B) must always be evaluated.
Important!
Ì
The example shows only an excerpt that is relevant for connection of the CTP system. The exam-
ple illustrated here does not show complete system planning. The user is responsible for safe inte-
gration into the overall system. Detailed application examples can be found at www.euchner.com.
Simply enter the order number in the search box. All available connection examples for the device
can be found in “Downloads.”
24 V DC
-F1
-S1
0 V
Connected
load
Safety Outputs
Door
Monitoring
Read Head
Actuator
Monitoring Outputs
5
OI
Diagnostic
Locking
active
UB
2
IMP
1
8
0V
7
OL
6
OD
3
FO1A
4
FO1B
CTP
Figure 3:
Connection example, version with plug connector M12