Operating Instructions

Non-Contact Safety Switch 

CES-I-AR-.-C04/C14-… (Unicode/Multicode)

Содержание CES-I-AR-.-C04 Series

Страница 1: ...EN Operating Instructions Non Contact Safety Switch CES I AR C04 C14 Unicode Multicode ...

Страница 2: ...g guard AM C C04 EX 137528 9 7 1 1 Dimension drawing of housing guard AM C C04 EX 137528 9 7 2 Mounting 9 8 Mounting 10 9 Electrical connection 12 9 1 Notes about 13 9 2 Safety in case of faults 13 9 3 Fuse protection for power supply 13 9 4 Requirements for connecting cables 13 9 5 Maximum cable lengths 14 9 5 1 Determining cable lengths using the example table 15 9 6 Connector assignment of safe...

Страница 3: ...chnical data for safety switch CES I AR C14 28 12 2 1 Dimension drawing of safety switch CES I AR C14 29 12 3 Typical system times 30 12 4 Technical data for actuator CES A BBN C04 CES A BBN C04 EX 137527 31 12 4 1 Dimension drawing 31 12 4 2 Operating distances 31 12 4 3 Typical actuating range in installation position A 32 12 5 Technical data for actuator CES A BDN 06 33 12 5 1 Dimension drawing...

Страница 4: ...is available for download at www euchner com DANGER WARNING CAUTION Safety precautions Danger of death or severe injuries Warning about possible injuries Caution slight injuries possible NOTICE Important Notice about possible device damage Important information Tip Useful information 1 4 Supplementary documents The overall documentation for this device consists of the following documents Document ...

Страница 5: ...EC 62061 Correct use includes observing the relevant requirements for installation and operation particularly based on the following standards Ì EN ISO 13849 1 Ì EN ISO 14119 Ì EN 60204 1 The safety switch is only allowed to be operated in conjunction with the intended EUCHNER CES actuators and the related connection components from EUCHNER On the use of different actuators or other connection com...

Страница 6: ...s the safe function of the safeguard should be checked at suitable intervals as part of the maintenance schedule WARNING Danger to life due to improper installation or due to bypassing tampering Safety components fulfill a personnel protection function Ì Safety components must not be bypassed turned away removed or otherwise rendered ineffec tive On this topic pay attention in particular to the me...

Страница 7: ...assignment ensures a particularly high level of protection against tampering When the guard is closed the actuator is moved towards the safety switch When the operating distance is reached power is supplied to the actuator by the switch and data are transferred If a permissible code is detected the safety outputs are switched on The safety outputs are turned off when the guard is opened In the eve...

Страница 8: ...tors that also have an ATEX rating for the same zone Ì Use connection components and connecting cables from EUCHNER Ì The connecting cable must be laid such that it is protected against mechanical damage Ì In addition a mechanical barrier is to be provided on the connecting cable as per EN 60079 14 section 9 3 9 to prevent flame propagation from the non potentially explosive atmosphere to the pote...

Страница 9: ...ex A point b may be used If damage or wear is found the complete switch including housing guard and actuator must be replaced Replacement of individual parts or assemblies is not permitted The supplied type label must be affixed on the safety switch On use in potentially explosive atmospheres there is a danger of explosion due to electrical sparks Ì Never connect or disconnect connector when live ...

Страница 10: ...tallation Ì Safety switches and actuators must not be used as an end stop Ì Observe EN ISO 14119 2013 sections 5 2 and 5 3 for information about mounting the safety switch and the actuator Ì From the assured release distance Sar the safety outputs are safely shut down Ì When mounting several safety switches observe the stipulated minimum distance to avoid mutual interference min 80 mm min 80 mm CE...

Страница 11: ...de approach direction See chapter 12 Technical data section Typical actuating range for the related actuator when the guard is open up to the distance Sar assured release distance a hazard is excluded the actuator is positively mounted on the guard e g by using the safety screws included The safety screws cannot be removed or tampered with using simple means Ì Pay attention to the maximum tighteni...

Страница 12: ... processes Ì The inputs on a connected evaluation unit must be positive switching as the two outputs on the safety switch deliver a level of 24 V in the switched on state Ì All the electrical connections must either be isolated from the mains supply by a safety transformer according to IEC 61558 2 6 with limited output voltage in the event of a fault or by other equivalent isolation measures PELV ...

Страница 13: ...cuit proof Ì A short circuit between the safety outputs is detected by the switch Ì A short circuit in the cable can be excluded by laying the cable with protection 9 3 Fuse protection for power supply The power supply must be provided with fuse protection depending on the number of switches and the current required for the outputs The following rules apply Max current consumption of an individual...

Страница 14: ...nce see table below with example data and case example SPS PLC l1 l2 lmax 200 m ln umin 24 V 10 un 24 V 20 5 x 0 34 mm2 5 x 0 34 mm2 5 x 0 14 mm2 5 x 0 34 mm2 CES I AR n CES I AR n 1 CES I AR 1 iout n Max number of switches IOD mA Possible output current per channel FO1A FO1B l1 m Max cable length from the last switch to the control system 0 14 mm 0 34 mm 5 10 70 140 25 50 110 50 35 80 100 25 50 2...

Страница 15: ...nected downstream that consumes 75 mA at each of the two safety inputs This operates over the whole temperature range with a voltage of 19 2 V corresponds to 24 V 20 All the relevant values can now be determined using the example table 1 Select the corresponding section in the column n max number of switches In this case 6 switches 2 In column IOD possible output current per channel FO1A FO1B find...

Страница 16: ...ble input for channel 2 WH 2 UB Power supply DC 24 V BN 3 FO1A Safety output channel 1 GN 4 FO1B Safety output channel 2 YE 5 OD Monitoring output GY 6 FI1A Enable input for channel 1 PK 7 0V Ground DC 0 V BU 8 RST Reset input RD 9 7 Terminal assignment of safety switch CES I AR C14 Terminal assignment Designation Description Conductor coloring RD BN BU PK WH GN YE GY UB 0V FI1A FI1B FO1A FO1B OD ...

Страница 17: ...X3 1 UB X3 2 FI1A X3 3 0 V X3 4 FI1B X3 5 RST 12 12 097627 45 15 1 4 8 5 6 3 1 2 7 35 1 20 5 1 2 4 5 3 3 4 2 1 5 M x1 Ø 14 6 M x1 Y distributor 097627 Socket Connector assignment of safety switch CES I AR 8 pin plug and Y distributor 8 pin socket Pin Function X1 1 FI1B X1 2 UB X1 3 FO1A X1 4 FO1B X1 5 OD X1 6 FI1A X1 7 0 V X1 8 RST Socket M12x1 44 45 41 15 M12x1 15 15 M12x1 33 A B 4 8 5 6 3 1 2 7 ...

Страница 18: ...ncorrect connection Ì To ensure safety both safety outputs FO1A and FO1B must always be evaluated Important The example shows only an excerpt that is relevant for the connection of the CES system The example illustrated here does not show complete system planning The user is responsible for safe integration into the overall system Detailed application examples can be found at www euchner com Simpl...

Страница 19: ...m cannot however detect which safety door is open or on which switch a fault has occurred with this connection technology A special AR eval uation unit is required for this purpose see chapter 9 11 Information on operation on an AR evaluation unit on page 21 The series connection can also be realized via additional terminals in a control cabinet The safety outputs are permanently assigned to the r...

Страница 20: ...B RST 2 4 1 UB FI1A FI1B Safety Outputs Read Head Read Head Safety Outputs Safety Inputs Safety Inputs Y distributor Y distributor Y distributor Terminating plug Eval Unit Read Head Safety Outputs Safety Inputs 5 OUT 4 FO1B 2 UB 8 RST 6 FI1A 1 FI1B 7 0V 5 OUT 3 FO1A 4 FO1B 2 UB 8 RST 6 FI1A 1 FI1B 7 0V 0V 3 FO1A 4 FO1B S1 12 11 14 2 UB 8 RST 6 FI1A 1 FI1B 7 0V 5 OUT 3 FO1A 24V CES CES CES Figure 4...

Страница 21: ...ide sufficient electrical current Ì Always connect inputs FI1A and FI1B directly to a power supply unit or to outputs FO1A and FO1B of another EUCHNER AR device series connection Pulsed signals must not be present at inputs FI1A and FI1B Ì The safety outputs FO1A and FO1B can be connected to the safe inputs of a control system Prerequisite The input must be suitable for pulsed safety signals OSSD ...

Страница 22: ...tributor Y distributor Y distributor Terminating plug ET200 4 8 F DI 4 F DO X1 X1 Digital Output PWR Supply of the control DI4 DI0 DO M DO P DO 2 DC24V 3 M 2 UB 8 RST 6 FI1A 1 FI1B X2 3 LED1 X2 4 UCM X2 5 J 7 0V 5 OUT 3 FO1A 4 FO1B X2 1 0V UCM 2 UB 8 RST 6 FI1A 1 FI1B 7 0V 5 OUT 3 FO1A 4 FO1B 2 UB 8 RST 6 FI1A 1 FI1B 7 0V 5 OUT 3 FO1A 4 FO1B 24V 0V CES CET CES Figure 5 Connection example for mixed...

Страница 23: ...st actuator taught in Ì The number of teach in operations is unlimited Ì After starting the device remains in teach in standby state for 3 min If no new actuator is detect ed in this time the device changes to normal operation If the switch detects the actuator that was most recently taught in when in the teach in standby state this state is ended immediately and the switch changes to normal opera...

Страница 24: ...evice for the teach in operation and teaching in actuator on page 23 3 Close all guards in the chain 4 Actuate the reset for at least 3 s 24 V on RST On the safety switch that is positioned at a new actuator the green LED flashes at approx 1 Hz and the actuator is taught in This takes approx 1 min Do not switch off during this time and do not actuate reset The teach in operation has ended when all...

Страница 25: ...ctuator only short time after power up Switches that have not been taught in remain in teach in standby until the teach in operation starts closed off off 1 Hz Teach in operation X off off Positive acknowledgment after completion of teach in operation Fault display X off off 2 x Input fault e g missing test pulses illogical switch state from preceding device in the switch chain closed off off 3 x ...

Страница 26: ...fety outputs FO1A FO1B Semiconductor outputs p switching short circuit proof Output voltage U FO1A U FO1B 1 HIGH U FO1A UB 1 5 UB V DC HIGH U FO1B LOW U FO1A U FO1B 0 1 Switching current per safety output 1 200 mA Utilization category acc to EN IEC 60947 5 2 DC 13 24 V 200 mA Caution Outputs must be protected by a free wheeling diode in the case of inductive loads Off state current Ir 2 0 25 mA Mo...

Страница 27: ...itch CES I AR C04 C14 EN 12 1 1 Dimension drawing of safety switch CES I AR C04 10 6 M12x1 42 4 1 29 2 25 8 32 10 6 4 1 12 9 15 5 14 5 4 8 18 Active face LEDs Active face LEDs With M8 plug connector Connecting cable with flying lead Connecting cable with M12 plug connector Rubber support included With rubber support ...

Страница 28: ...1B LOW U FO1A U FO1B 0 1 Switching current per safety output 1 200 mA Utilization category acc to EN IEC 60947 5 2 DC 13 24 V 150 mA Caution Outputs must be protected by a free wheeling diode in the case of inductive loads Off state current Ir 2 0 25 mA Monitoring output DIA 1 p switching short circuit proof Output voltage 0 8 x UB UB V DC Max load 50 mA Rated insulation voltage Ui 300 V Rated imp...

Страница 29: ...ating Instructions Non Contact Safety Switch CES I AR C04 C14 EN 12 2 1 Dimension drawing of safety switch CES I AR C14 55 52 5 116 100 28 L 60 30 14 23 7 7 7 7 Ø8 Ø8 Ø8 Ø8 Ø4 6 Ø4 6 8 22 13 Cable end sleeves Active face LED status indication LED status indication Active face ...

Страница 30: ...fety outputs FO1A and FO1B are switched off after the risk time at the latest If several devices are operated in a series connection the risk time of the overall device chain will increase with each device added Use the following calculation formula tr tr e n x tl tr Total risk time tr e Risk time single device see technical data tl Risk time delay per device n Number of additional devices total n...

Страница 31: ...25 42 6 14 5 18 15 5 With rubber support Rubber support NOTICE Ì 2 safety screws M4x20 included Ì Rubber support included 12 4 2 Operating distances Actuating range for center offset m 0 in combination with safety switch CES C04 Installation position Parameter Value Unit A B min typ max Operating distance 15 mm Assured operating distance sao 1 10 Switching hysteresis 1 1 2 Assured release distance...

Страница 32: ...allation position Parameter Value Unit C D min typ max Operating distance 8 5 mm Assured operating distance sao 1 3 5 Switching hysteresis 1 1 2 Assured release distance sar in x z direction in y direction 37 5 57 5 1 On approach in x direction 12 4 3 Typical actuating range in installation position A only in combination with actuator CES A BBN C04 25 30 X 1 0 5 1 5 2 0 20 25 30 40 35 15 10 5 1 0 ...

Страница 33: ...distance C A Approach direction CAUTION Ì Do not mount at temperatures below 0 C Ì The actuator can be damaged during mounting 12 5 2 Operating distances Actuating range for center offset m 0 Installation position Parameter Value Unit A min typ max Operating distance 19 mm Assured operating distance sao 1 14 Switching hysteresis 1 2 Assured release distance sar in x z direction in y direction 40 6...

Страница 34: ...ension drawing Active face 32 42 25 12 4 B B 12 3 11 3 4 5 B B NOTICE Ì 2 safety screws M4x14 included 12 6 2 Operating distances Actuating range for center offset m 0 Installation position Parameter Value Unit A B min typ max Operating distance 30 mm Assured operating distance sao 1 15 Switching hysteresis 1 1 2 Assured release distance sar in x z direction in y direction 69 77 1 On approach in z...

Страница 35: ...rameter Value Unit min typ max Housing material Two component epoxy resin Dimensions 72 x 30 x 17 mm Weight 0 04 kg Ambient temperature 0 65 C Degree of protection IP65 IP67 IP69 IP69K Installation position Active face opposite read head Power supply Inductive via read head 12 7 1 Dimension drawing 30 14 17 6 6 6 6 8 55 72 Ø8 Ø4 6 Ø8 Ø4 6 Ø8 Ø8 Active face NOTICE Ì 2 safety screws M4x16 included ...

Страница 36: ...nce 24 20 mm Assured operating distance sao 1 10 11 Switching hysteresis 1 1 2 Assured release distance sar in x z direction in y direction 64 72 1 On approach in z direction Installation position Parameter Value ALUsurroundings PVC surroundings Unit D min typ max Operating distance 17 15 mm Assured operating distance sao 1 6 5 2 Switching hysteresis 1 1 2 Assured release distance sar in x z direc...

Страница 37: ...on with actuator CES A BBN C14 160441 For a side approach direction y direction for the actuator and safety switch a minimum distance of s 10 mm must be maintained so that the actuating range of the side lobes is not entered 18 26 Z Y Y 6 10 14 22 2 14 10 6 22 30 38 34 18 34 38 46 50 54 58 62 66 42 2 6 10 14 22 26 30 18 34 38 46 50 54 58 62 66 42 Z X 1 4 6 1 0 2 2 1 8 3 0 2 6 26 30 Figure 7 Typica...

Страница 38: ...ories or spare parts that can be ordered from EUCHNER may be replaced Regular inspection of the following is necessary to ensure trouble free long term operation Ì Check the switching function see chapter 10 3 Functional check on page 24 Ì Check the secure mounting of the devices and the connections Ì Check for soiling No servicing is required Repairs to the device are only allowed to be made by t...

Страница 39: ...39 2119563 12 03 20 Translation of the original operating instructions Operating Instructions Non Contact Safety Switch CES I AR C04 C14 EN 16 Declaration of conformity ...

Страница 40: ...Operating Instructions Non Contact Safety Switch CES I AR C04 C14 40 Translation of the original operating instructions 2119563 12 03 20 ...

Страница 41: ...41 2119563 12 03 20 Translation of the original operating instructions Operating Instructions Non Contact Safety Switch CES I AR C04 C14 EN ...

Страница 42: ...Operating Instructions Non Contact Safety Switch CES I AR C04 C14 42 Translation of the original operating instructions 2119563 12 03 20 ...

Страница 43: ...43 2119563 12 03 20 Translation of the original operating instructions Operating Instructions Non Contact Safety Switch CES I AR C04 C14 EN ...

Страница 44: ...ner com Edition 2119563 12 03 20 Title Operating Instructions Non Contact Safety Switch CES I AR C04 C14 Translation of the original operating instructions Copyright EUCHNER GmbH Co KG 03 2020 Subject to technical modifications no responsibility is accept ed for the accuracy of this information ...