Functional description 

General 

The CES-AP is part of an interlocking device in accordance with EN ISO 14119. The two safe outputs of the last CES-AP are 

connected to a PNOZ s4.1 safety relay. 

Connections 

Designation 

Function 

Use in this example 

FO1A, FO1B 

Safety outputs. HIGH when the safeguarding device 

is closed and the actuator is in operating distance. 

Switch-off of at least one of the outputs leads to a direct 
switch-off of the safety contacts (13 – 14, 23 – 24, …) of 

the safety relay PNOZ s4.1. 
Important: The actual shutdown of the energy which is 

causing a hazard in a machine is not shown in the example 

and must be supplemented. 

OD 

Monitoring output. HIGH when outputs FOIA and 

FOIB are switched on (safety guard closed). 

Function is not used. 

Safety assessment 

The CES-AP features complete monitoring for faults in the safety-relevant parts and in the connected cables (clock pulses at 
outputs FO1A and FO1B). The safety relay PNOZ s4.1 achieve up to PL e according to the manufacturer’s information (see the 

device’s operating instructions for this purpose). The wiring corresponds to the circuit “light barrier or safety switch with detection 

of shorts across contacts via ESPE” in the operating instructions of the PNOZ s4.1. Therefore, PL e in accordance with EN ISO 

13849-1 can be achieved for position monitoring of a safety guard and for interlocking (preventing the operation of a machine 
element under certain conditions). 

Important: Switch-off of the energy and any necessary monitoring energy switch-off (feedback loop) of the hazard are not part of 

this document and must be added in accordance with the risk assessment for the machine. In this example, the safety evaluation 

unit without feedback loop and without start button is used. Please refer to the operating instructions of the safety evaluation unit 
for more information.  

Содержание CES-I-AP-M-C04-USB-117324

Страница 1: ...used 2 EUCHNER 2 Other 2 Functional description 3 General 3 Connections 3 Safety assessment 3 Principle circuit diagram 4 Setting of the operating mode selector switch mode 5 Automatic manual start without short circuit detection 5 Monitored start rising edge without short circuit detection 5 Monitored start falling edge without short circuit detection 5 Setting of the Reset for PNOZ s4 1 6 Manual...

Страница 2: ...ording to EN ISO 13849 Category 4 PL e Components modules used EUCHNER Description Order no item designation Safety switches with transponder technology 116502 CES I AP U C04 USB 11650 117324 CES I AP M C04 USB 117324 Tip More information and downloads about the above mentioned EUCHNER products can be found at www EUCHNER de Simply enter the order number into the search field Other Description Ite...

Страница 3: ... Safety assessment The CES AP features complete monitoring for faults in the safety relevant parts and in the connected cables clock pulses at outputs FO1A and FO1B The safety relay PNOZ s4 1 achieve up to PL e according to the manufacturer s information see the device s operating instructions for this purpose The wiring corresponds to the circuit light barrier or safety switch with detection of s...

Страница 4: ...cal modifications no responsibility is accepted for the accuracy of this information EUCHNER 2015 AP000178 02_03 15 Page 4 of 7 Principle circuit diagram In the example Automatic Reset of the PNOZ s4 1 is used Figure 1 ...

Страница 5: ... without short circuit detection Operating mode selector switch mode Automatic manual start Without short circuit detection ATTENTION For an automatic start push button S2 has to be replaced by a bridge Monitored start rising edge without short circuit detection Operating mode selector switch mode Monitored start rising edge Without short circuit detection Monitored start falling edge without shor...

Страница 6: ... is accepted for the accuracy of this information EUCHNER 2015 AP000178 02_03 15 Page 6 of 7 Setting of the Reset for PNOZ s4 1 Only with the following settings does the safety relay PNOZ s4 1 operate correctly with a CES AP Manual Reset Automatic Reset ...

Страница 7: ...nly as assistance for the considerations about safety measures The design engineer of a machine installation is obligated to assess the safety technology himself The examples must not be used for assessment because only a small excerpt of a complete safety function was considered in terms of safety engineering here In order to be able to use the safety switch applications correctly on safety guard...

Отзывы: