EUCHNER CES-AH-C03-AE-LS Скачать руководство пользователя страница 23

23

2105267-10-08/20 (Translation of the original operating instructions)

Operating Instructions

Non-Contact Safety Switch CES-AH-C03-AE-LS

EN

15.  Declaration of conformity

  

             

  

                             

 

 

                                                                          

27.07.2020 - NG - KB - Blatt

/Sheet/ Page/Pagina/ Página

 1                                                                                                                                                      

Vorlage Rev 01

 

EUCHNER GmbH + Co. KG  Kohlhammerstraße 16  70771 Leinfelden-Echterdingen Tel. +49/711/7597-0  Fax +49/711/753316 www.euchner.de   [email protected] 

 

 

 

EU-Konformitätserklärung                                                   

Original DE  

 

EU declaration of conformity 

                                                          

Translation EN  

 

Déclaration UE de conformité  

                                                    

 

Traduction FR

 

 

Dichiarazione di conformità UE

 

Traduzione IT 

 

Declaración UE de conformidad 

Traducción ES 

 

Die nachfolgend aufgeführten Produkte sind konform mit den Anforderungen der folgenden Richtlinien (falls zutreffend): 

The beneath listed products are in conformity with the requirements of the following directives (if applicable): 

Les produits mentionnés ci-dessous sont conformes aux exigences imposées par les directives suivantes (si valable) 

I prodotti sotto elencati sono conformi alle direttive sotto riportate (dove applicabili): 

Los productos listados a continuación son conforme a los requisitos de las siguientes directivas (si fueran aplicables): 

 

I: 

Maschinenrichtlinie  

Machinery directive  

Directive Machines  

Direttiva Macchine 

Directiva de máquinas 

  

2006/42/EG 

2006/42/EC 

2006/42/CE 

2006/42/CE 

2006/42/CE 

II: 

RoHS Richtlinie 

RoHS directive 

Directive de RoHS 

Direttiva RoHS 

Directiva RoHS

 

2011/65/EU 

2011/65/EU  

2011/65/UE 

2011/65/UE 

2011/65/UE 

 

Die Geräte sind für die Einhaltung der Schutzziele der EMV Richtlinie 2014/30/EU vorbereitet. Die abschließende Überprüfung der 

Konformität muss gemäß der Betriebsanleitung in der jeweiligen Anwendung vom Inverkehrbringer durchgeführt werden. 

The devices are prepared for compliance with the protective goals of EMC Directive 2014/30/EU. The distributing company is responsible for 

performing the final conformity check in accordance with the operating instructions in the respective application. 

Les appareils sont préparés pour respecter les objectifs de protection de la directive CEM 2014/30/UE. La vérification finale de la conformité 

doit être réalisée par le metteur sur le marché conformément au mode d’emploi dans l’application spécifique.

 

I dispositivi sono predisposti per il conseguimento degli obiettivi di protezione della direttiva EMC 2014/30/UE. La verifica definitiva della con-

formità dovrà essere eseguita, secondo le istruzioni di impiego, nell'applicazione specifica, dal responsabile dell'immissione sul mercato. 

Los dispositivos están preparados para cumplir los fines de protección especificados en la Directiva CEM 2014/30/UE. La comprobación 

final de la conformidad debe llevarla a cabo la persona encargada de la comercialización, según el manual de instrucciones y en la aplica-

ción correspondiente. 

 

Folgende Normen sind angewandt: 

a: 

EN ISO 14119:2013         

 

 

Following standards are used: 

b: 

EN ISO 13849-1:2015 

 

 

Les normes suivantes sont appliquées: 

c: 

EN 60947-5-3:2013 without clause 8.6 

 

 

Vengono applicate le seguenti norme:

 

d: 

EN IEC 63000:2018 (RoHS)

 

 

 

Se utilizan los siguientes estándares: 

 

 

 

 

 

 

 

 

 

 

 

Leinfelden, July 2020 

i.A. Dipl.-Ing. Richard Holz 

i.A. Dipl.-Ing. (FH) Duc Binh Nguyen 

 

Leiter Elektronik-Entwicklung 

Dokumentationsbevollmächtigter 

EUCHNER GmbH + Co. KG 

Manager Electronic Development 

Documentation manager 

Kohlhammerstraße 16 

Responsable Développement Électronique 

Responsable documentation 

70771 Leinfelden-Echterdingen

 

Direttore Sviluppo Elettronica 

Responsabilità della documentazione 

Germany

 

Director de desarrollo electrónico

 

Agente documenta 

Bezeichnung der Bauteile 

Type 

Richtlinie 

Normen 

Prüfbericht  

Description of components 

Type

 

Directives

 

Standards

 

Test report 

Description des composants 

Type

 

Directive

 

Normes

 

Rapport du test 

Descrizione dei componenti 

Tipo

 

Direttiva

 

Norma

 

Rapporto di prova    

Descripción de componentes

 

Typo 

Directivas 

Estándares 

Informe de prueba 

Sicherheitsschalter 

Safety Switches 

Interrupteurs de sécurité 

Finecorsa di sicurezza 

Interruptores de seguridad 

 

CES-AH-C03-AE-LS-110370 

CES-AH-C03-AE-LS-100255 

I, II 

a, b, c, d 

Euchner QS PB 021/2010 

Euchner QS PB 004/2016

 

Betätiger 

Actuator 

Actionneur 

Azionatore 

Actuador

 

CES-A-BRN-100251 

I, II 

a, b, c, d 

Euchner QS PB 021/2010 

Euchner QS PB 004/2016 

Die alleinige Verantwortung für die Ausstellung dieser Konformitätserklärung trägt der Hersteller: 

EUCHNER GmbH + Co. KG 

This declaration of conformity is issued under the sole responsibility of the manufacturer:

 

Kohlhammerstraße 16 

La présente déclaration de conformité est établie sous la seule responsabilité du fabricant:

 

70771 Leinfelden-Echterdingen 

La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva del fabbricante:

  Germany 

La presente declaración de conformidad se expide bajo la exclusiva responsabilidad del fabricante:

 

 

212

73

87

-0

4-

07

/20

 

Содержание CES-AH-C03-AE-LS

Страница 1: ...EN Operating Instructions Non Contact Safety Switch CES AH C03 AE LS Unicode ...

Страница 2: ...estart and start button 10 8 5 Safety in case of faults 10 8 6 Fuse protection for power supply 10 8 7 Voltage drop on cables and switch 10 8 7 1 Calculation example 10 8 8 Connecting cables and plug connectors 11 8 9 Connector assignment of safety switch CES AH 12 8 10 Connection of the CES AH 12 9 Setup 13 9 1 LED displays 13 9 2 Teach in function for actuator 13 9 2 1 Carrying out teach in for ...

Страница 3: ...ion of the original operating instructions Operating Instructions Non Contact Safety Switch CES AH C03 AE LS EN 12 Ordering information and accessories 22 13 Inspection and service 22 14 Service 22 15 Declaration of conformity 23 ...

Страница 4: ...ment is available for download at www euchner com DANGER WARNING CAUTION Safety precautions Danger of death or severe injuries Warning about possible injuries Caution slight injuries possible NOTICE Important Notice about possible device damage Important information Tip Useful information 1 4 Supplementary documents The overall documentation for this device consists of the following documents Docu...

Страница 5: ...in the system family CES AH have special safety outputs that are suitable for the direct switching of large loads In appropriate applications it is therefore not necessary to connect power relays or contactors in between The device interrupts the supply of power to the load if e g the guard is open Correct use includes observing the relevant requirements for installation and operation particularly...

Страница 6: ...f the safeguard should be checked at suitable intervals as part of the maintenance schedule WARNING Danger to life due to improper installation or due to bypassing tampering Safety components fulfill a personnel protection function Ì Safety components must not be bypassed turned away removed or otherwise rendered ineffec tive On this topic pay attention in particular to the measures for reducing t...

Страница 7: ...to the fixed part of the guard The actuator attached to the movable part of the guard is moved towards the read head fitted in the safety switch by closing the door When the operating distance is reached power is supplied to the actuator by the inductive read head and data can be transferred The bit pattern read is compared with the code saved in the safety switch If the data match the safety outp...

Страница 8: ...hange as a function of the installation depth and the guard material Operating distance Actuator Operating distance Actuator Flush mounting Surface mounting Note the following points Ì Actuator and safety switch must be easily accessible for inspection and replacement Ì Actuator and safety switch must be fitted so that the front faces are at the minimum operating distance 0 8 x Sao or closer when ...

Страница 9: ...ng several milliseconds on switching off the outputs Ì To prevent overvoltages on the inputs and outputs for the safety circuits inductive loads must be connected with free wheeling diodes see chapter 8 10 Connection of the CES AH on page 12 Ì Power devices which are a powerful source of interference must be installed in a separate location away from the input and output circuits for signal proces...

Страница 10: ...voltage UB is reverse polarity protected Ì The contacts LA LA and LB LB are short circuit proof and protected against reverse polarity Ì To prevent switching on of the load connected in the case of a short circuit between LA or LB and the operating voltage UB the cables must be laid rigidly and with protection 8 6 Fuse protection for power supply The power supply must be provided with fuse protect...

Страница 11: ... Ì Use EUCHNER connectors Ì If other connection components are used the following recommendations apply EUCHNER pro vides no warranty for safe function in case of failure to comply with these requirements Ì The maximum cable length should not exceed 50 m Recommended connecting cable e g LiYY 7 x 1mm Ölflex classic 400P 7 x 0 75 Terminating plug for the mating side AMP Superseal series manufacturer...

Страница 12: ...channel 1 GY 6 2 LA Safety output channel 1 PK 7 3 LB Input for channel 2 YE 5 4 LB Safety output channel 2 GN 4 8 10 Connection of the CES AH GND UB F1 CES AH C03 AE LS UB X1 1 0V X1 2 Start X1 3 LA X2 1 AMP Superseal LA X2 2 LB X2 3 LB X2 4 Load 2 2 3 3 1 1 Load e g valve coil DC motor ohmic load etc 2 In case of inductive loads it is imperative free wheeling diodes are used to protect the outpu...

Страница 13: ...preceding device if teach in is carried out for a new actuator Teach in is not possible again immediately for this device if a new teach in operation is carried out The disabled code is deleted again in the safety switch only after a third code has been taught Ì The safety switch can be operated only with the last actuator taught in Ì If the switch detects an actuator that has already been taught ...

Страница 14: ...are no persons in the danger zone Ì Observe the valid accident prevention regulations 1 Switch on operating voltage Ì The safety switch carries out a self test The green STATE LED flashes for 3 s at 10 Hz The green STATE LED then flashes at regular intervals 2 Close all guards Ì The machine must not start automatically Ì The green STATE LED illuminates continuously 3 Enable operation in the contro...

Страница 15: ... ready for teach in for another actuator only short time after power up Setup closed off 1 Hz Teach in operation X off Positive acknowledgment after completion of teach in operation Fault display X off 2 x Overload e g short circuit on a safety output X off 3 x Over temperature X off 4 x Output fault e g fault on a switching element X off 5 x Internal fault e g component fault data error or short ...

Страница 16: ...B 0 25 10 A Power supply for load U LA U LB UB Power supply for load via PWM Pulse frequency 1 kHz Mark space ratio Ton 10 100 Safety outputs LA LB Semiconductor outputs p switching short circuit proof Output voltage U LA U LB 1 HIGH U LA UB 1 5 UB V DC HIGH U LB LOW U LA U LB 0 4 Testing of the outputs Test pulse length Test interval 10 6 ms s Switching current per safety output 30 4 000 mA Utili...

Страница 17: ...PFHD 1 03 x 10 7 h Mission time 20 years 1 Values at a switching current of 4 A without taking into account the cable lengths 2 After the operating voltage is switched on the semiconductor outputs are switched off during the ready delay 3 The dwell time of an actuator inside and outside the actuating range must be at least 0 5 s to ensure reliable detection of internal faults in the evaluation uni...

Страница 18: ...slight time offset They have the same signal state at the latest after a difference time of 50 ms System times for reset after a fault and normal operation Secondary conditions UB 24 V LA permanently connected with UB LB switched by control system Actuator moved t Actuator Start LA LB LB DIA LED red off on 0 V 24 V 0 V 24 V 0 V 24 V 0 V 24 V None Detected Start Fault detection Occurrence of a faul...

Страница 19: ...ch CES AH C03 AE LS EN 11 3 Dimension drawing and connector assignment PUR PVC X2 4 3 2 1 X1 1 2 3 168 0 3 27 5 34 5 15 40 40 3 40 40 20 30 45 5 90 40 5 3 5 3 7 3 Cable length 2 000 mm LED status indication View of connection side Active face Active face with approach direction C Active face with approach direction A ...

Страница 20: ...data for actuator CES A BRN Parameter Value Unit min typ max Housing material PPS Dimensions 80 x 40 x 15 mm Weight 0 06 kg Ambient temperature 25 70 C Degree of protection IP67 Installation orientation Active face opposite read head Power supply Inductive via read head 11 4 1 Dimension drawing Active face Active face 40 80 10 3 5 5 17 11 17 11 15 8 5 ...

Страница 21: ...hysteresis 1 3 Assured release distance sar 75 1 The values apply to surface installation of the actuator on steel Typical actuating range only in combination with actuator CES A BRN on surface mounting on steel 5 2 0 2 5 3 0 3 5 Z X 5 15 20 50 45 40 35 30 25 50 Y 5 10 15 20 25 30 35 40 45 50 55 60 65 10 5 15 25 30 40 45 50 55 60 65 1 5 1 0 10 20 35 For a side approach direction for the actuator a...

Страница 22: ...es or spare parts that can be ordered from EUCHNER may be replaced Regular inspection of the following is necessary to ensure trouble free long term operation Ì Check the switching function see chapter 9 3 Functional check on page 14 Ì Check the secure mounting of the devices and the connections Ì Check for soiling No servicing is required Repairs to the device are only allowed to be made by the m...

Страница 23: ...ttiva EMC 2014 30 UE La verifica definitiva della con formità dovrà essere eseguita secondo le istruzioni di impiego nell applicazione specifica dal responsabile dell immissione sul mercato Los dispositivos están preparados para cumplir los fines de protección especificados en la Directiva CEM 2014 30 UE La comprobación final de la conformidad debe llevarla a cabo la persona encargada de la comerc...

Страница 24: ...euchner com Edition 2105267 10 08 20 Title Operating Instructions Non Contact Safety Switch CES AH C03 AE LS Translation of the original operating instructions Copyright EUCHNER GmbH Co KG 08 2020 Subject to technical modifications no responsibility is accept ed for the accuracy of this information ...

Отзывы: