(Translation of the original operating instructions) 2098039-20-02/20
12.5. Technical data of actuator CES-A-BRN
Parameter
Value
Unit
min.
typ.
max.
Housing material
PPS
Dimensions
80 x 40 x 15
mm
Weight
0.06
kg
Ambient temperature
- 25
-
+ 70
°C
Degree of protection
IP67
Installation orientation
Active face opposite read head
Power supply
Inductive via read head
12.5.1. Dimension drawing
40
80
10,3
5,5
17
11
17
11
15
8,5
Active face
Active face
NOTICE
2 safety screws M5x16 included.
12.5.2. Operating distances
Actuating range for center offset m = 0
1)
Parameter
Value
Unit
min.
typ.
max.
Operating distance
-
27
-
mm
Assured operating distance s
ao
20
-
-
Switching hysteresis
-
3
-
Assured release distance s
ar
-
-
75
2)
1) The values apply to surface mounting of the actuator on metal.