As show in the above figure, suppose
①
color LED control card is connecting to
①
MR-900W, and
②
color LED card is connecting to
②
MR-900W. In this case, the TCP port for
①
color LED control card is
5200, then you need to set
the
①
MR-900W’s
port for User Agent Client as 5200 as well. At this time the
①
MR-900 connects to mServer and displayed as online, and maps to TCP port 5200 over mServer. For the
①
color LED control card, you also set the communication port as 5200. At the same time
②
MR-900W
displayed as online over mServer as well. Since the TCP port 5200 has been occupied by
①
MR-900W, you
need to map the
②
MR-900W to a port other than TCP 5200 port over the mServer, such as TCP 5300 port.
Therefore, you should set the
②
color LED control card’s communication port as 5300, which means
②
LED control card will update data through port 5300. In short, you need to set the communication port for
LED control card as same as the
User Agent Client port for MR-900. Meanwhile, the mapping TCP port over
the mServer needs to match the communication port that is defined in the LED control card software.
However it is not necessary that both end of the ports are the same.