MD-649 User Manual
15
website(http://www.etungtech.com)
Click button "Settings" in the upper side of the user interface,
and in the popup dialog with title "Settings", select the serial port
that is used to configure MD-649, then click OK:
Figure 2-1: Setting serial port
Click "Start configuration" based on the prompt, and power on
MD-649 quickly within 30 seconds; when the information about
MD-649 model appears, press Enter, then the first item of the
configuration menu appears: "1) Data center domain or IP ()",
then input domain of the data center: eyun.etungtech.com (or
press Enter to use the default value in the bracket. The default
value is eTung server domain, please input your own domain or
IP address if you have built your own server).
Press Enter, then the second configuration item appears:
"Data center port (8080)", input mServer's listening port "8080"
(or press Enter directly to use the default value in the bracket.
This port is the public port of eTung server, input your own port
if you have built your own server or leased a dedicated port).