Command formats
•
All
commands
received
must
be
RS232,
2400
Baud,
8N1
(8
data
bits,
No
parity
and
1
stop
bit).
•
All
commands
must
be
ASCII
characters
and
all
letters
must
be
upper
case.
•
Each
command
string
must
be
immediately
followed
with
a
<CR>
(0D
hex)
character
to
mark
the
end
of
transmission.
DO
NOT
add
a
<LF>
(0A
hex)
after
<CR>.
•
All
single
digit
channel
addresses
must
have
an
ASCII
0
zero
preceding
them.
00
is
not
a
valid
channel
number.
Example:
01,02,03
•
All
channels
addressed
in
the
“multi
channel
format”
described
below
must
have
commas
as
separators
between
channel
numbers.
01
‐
99
is
the
valid
range.
Example:
MI,01,50,99<CR>
•
Commands
may
be
combined
with
the
asterisk
*
(2A
hex)
command
separator
character
to
form
a
single
command
transmission
string
as
in
the
following
format
Example:
MI01*SO01,99*MI02*BO16,32<CR>.
•
Each
command
must
be
5
characters
minimum
in
length
including
the
<CR>
character.
Single
combined
command
strings
cannot
exceed
48
chars
total.
•
Because
there
is
no
report
back
of
switcher
channel
status
to
the
host
computer
from
the
switchers,
it
is
highly
recommended
that
a
global
command
such
as
BN<CR>
preface
all
switching
commands.
This
way
you
will
always
know
all
channels
are
off
before
turning
any
channels
on.
Other
approaches
are
valid,
but
require
keeping
track
of
enabled
channels
in
the
host
software.
MICROPHONES (M=Microphone)
Function Command
MICROPHONE
“IN”
MIxx<CR>
(xx=01
‐
99)
01=1,
02=2,
etc.
Multi
channel
format:
MI01,99 <CR>
MICROPHONE
“OUT”
MOxx<CR>
(xx=01
‐
99)
01=1,
02=2,
etc.
Multi
channel
format:
MO01,99<CR>
MICROPHONE
“ALL”
MA<CR>
MICROPHONE
“NONE”
MN<CR>
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
SPEAKERS (S=Speaker)
Function Command
SPEAKER
“IN”
SIxx<CR>
(xx=01
‐
99)
01=1,
02=2,
etc.
Multi
channel
format:
SI01,99<CR>
SPEAKER
“OUT”
SOxx<CR>
(xx=01
‐
99)
01=1,
02=2,
etc.
Multi
channel
format:
SO01,099<CR>
SPEAKER
“ALL”
SA<CR>
SPEAKER
“NONE”
SN<CR>
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
BOTH MICROPHONES and SPEAKERS (B=both)
Function Command
MIC
AND
SPEAKER
“IN”
BIxx<CR>
(xx=01
‐
99)
01=1,
02=2,
etc.
Multi
channel
format:
BI01,99<CR>
MIC
AND
SPEAKER
“OUT”
BOxx<CR>
(xx=01
‐
99)
01=1,
02=2,
etc.
Multi
channel
format:
BO01,99<CR>
MIC
AND
SPEAKER
“ALL”
BA<CR>
MIC
AND
SPEAKER
“NONE”
BN<CR>
Warranty
All
ETS
products carry a one year parts and labor warranty. This warranty does not cover damages as a result of misuse, improper handling of the unit
or exposure to extreme temperatures or moisture. At its discretion,
ETS
reserves the right to repair or replace this unit under the conditions of the
warranty. If you experience problems with your equipment call
ETS
at: 505-888-3923 to obtain a return authorization number. Equipment requiring repair
beyond the warranty period or units that have been damaged or are not covered under the warranty can be repaired by
ETS
for a minimal cost under
most conditions.
Made in the USA by
ETS Inc.
Содержание SS8-RC
Страница 3: ......