SAFETY NOTES 

 
 
 

The  SDV1092-8  Mixer  /  Equaliser  is  a  complex 
piece  of  electrical  apparatus  and  as  such  certain 
precautions  should  be  taken  when  using  this 
equipment.  These  precautions  are  generally 
commonsense  but  are  repeated  here  for  the  user’s 
guidance.  Operation  of  the  unit  in  an  un-safe 
manner will void any warranty on the product and 
could  be  detrimental  to  the  health  of  the  product 
and or user.   
 
When using the product the user should ensure that they: 
 

1)  Read  this  manual  before  undertaking  an  installation  using  the 
equipment. 
 
2)  Keep the instructions in a safe place for future reference 
 
3)  Take note and comply with all safety warnings in this manual and on 
the equipment. 
 
4)  Do not install the equipment near any heat sources such as radiators, 
stoves. 
 
5)  Do not expose the unit to water or moisture 
 
6)  Do not expose the unit to naked flames 
 
7)  Do not operate the unit in ambient temperatures exceeding 35°C. 
 
8)  Do not attempt to perform any internal adjustments unless authorized 

to do so by Semelab personnel. The unit has no user serviceable parts. 

 
9)

 

Protect  the  power  cord  from  being  pinched  or  otherwise  damaged 
particularly when plugged into a wall socket or extension cord and at 
the point of entry from the unit.  

 
10)Do not dispose of the unit, contact Semelab Plc for suitable recycling. 

Do not expose this appliance to rain or moisture.

Refer servicing to qualified service personnel.

Do not open - No user serviceable parts inside.

To reduce the risk of fire or electric shock,

MAINS

CAUTION: For continued
protection against risk of

same type of fuse

fire,  Replace  only  with

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION

WARNING: SHOCK HAZARD - DO NOT OPEN

E

TS

Содержание SDV1092-8

Страница 1: ...assumed for the use of information contained herein nor for any infringement of patent or rights of others that may result from such use No license is granted by implication or otherwise under any pa...

Страница 2: ...se is granted by implication or otherwise under any patent or patent right of EcoTec Systems Ltd 2 CONTENTS CONTENTS 2 SAFETY NOTES 3 INTRODUCTION 4 USER CONTROLS 7 VOLUME CONTROL 7 MUSIC SOURCE SELEC...

Страница 3: ...2 Keep the instructions in a safe place for future reference 3 Take note and comply with all safety warnings in this manual and on the equipment 4 Do not install the equipment near any heat sources su...

Страница 4: ...trol of the music volume for up to 8 zones 3 14 band graphic equaliser to set the optimum music system profile not user adjustable 4 Short circuit protection on all outputs 5 Manual front panel or rem...

Страница 5: ...actioned via a signal for the venue fire alarm The unit has the necessary circuitry to interface with an additional paging microphone To reduce space taken up by the music equipment selected music sou...

Страница 6: ...S visible from the slider controls positions In addition indicators are provided to show the installer that there is a signal present This is in the form of a green LED which flashes in sequence to th...

Страница 7: ...lume knobs which control the music levels in their respective zones the music source selection knob and the MUTE button VOLUME CONTROL The volume controls operate in a conventional fashion rotating th...

Страница 8: ...yer option has been fitted then the unit will have a built in music source To use the internal music source the music source selector should be set to the internal source setting Again highlighted spa...

Страница 9: ...erneath the unit can be removed by withdrawing the centre plastic pin from each foot For optimum operation position the unit away from direct sources of heat and sources of electric and magnetic field...

Страница 10: ...used the remote switch is connected to the remote connector on zone 1 The remote source selector unit will also control the music volume remotely The remote selector controls can typically be located...

Страница 11: ...ti clockwise until the front top panel is released support the front panel whilst undoing the locking bolts To adjust the equalisation setting move the slider controls up or down to increase or decrea...

Страница 12: ...nables announcements to be made over the music Once the microphone is released the original music volume is restored MUSIC OUTPUTS The music output for each zone is via Weidmuller terminal connectors...

Страница 13: ...ingle core screened cable should be used and there will be no connection to pin 3 on the output socket REMOTE MUSIC MUTE FIRE ALARM INTERFACE A remote mute facility is provided to enable a signal from...

Страница 14: ...tput connector wired correctly Are gain settings too low De select MUTE Connect source to line input and set music source selector accordingly Rectify any connection problem Adjust input gain setting...

Страница 15: ...Hz 3dB Distortion 0 1 20Hz to 20KHz Sensitivity adjustment for 1Vrms input 300mA to 3V rms Input Gain 20dB Input Impedance 47K Noise 90dB Microphone Frequency Response 20Hz to 20KHz 3dB Distortion 1 2...

Отзывы: