background image

Care and Maintenance

Cleaning After Use

Clean and disinfect your tanning bed’s bench and canopy after each
use. Use a non-abrasive disinfectant cleaner that 

does not contain

ammonia or ammonia derivatives

. Ammonia may damage the acrylic

shield. Spray the acrylic lightly with disinfectant and wipe dry with a
clean soft cloth.

Thorough Periodic Cleaning

The cooling fans draw air through the bed and will cause a dust
buildup on the lamps and reflectors. When a dust buildup is observed,
it is necessary to thoroughly clean the inside of the bench and canopy.

1

Remove the acrylic shields and lamps.

2

With a soft cloth, wipe the entire length of each lamp.

3

Clean both sides of the acrylic shields with a non-ammonia dis-
infectant cleaner.

4

Wipe the reflectors with a clean damp cloth.

5

Re-install the lamps and acrylic shields.

Mechanical Inspection

Inspect the unit’s mechanical integrity every 400-500 hours of use.

• Inspect the unit’s fasteners verifying that all are firmly in place.

Pay particular attention to the hinge bolts.

• Inspect gas springs for signs of wear. Replace gas springs that will

not hold the canopy in the full open position when raised.

• Inspect the AC power cord and its connections.
• Inspect the acrylic. Replace if broken, cracked or badly scratched.

Hour Counter

This sunbed incorporates an ingenious hour counter function into the
timing circuitry. It allows the operator of the unit to monitor the hours
of use of the lamps, making it easy to determine when to change them.
You may also decide to use this function to monitor other time based
maintenance tasks.

To determine how many hours the unit has been in service (since the
last reset of the hour counter memory), first make sure the timer dis-
play shows “0”. Then simply hold the stop button for three seconds.
The display will show two pairs of numbers which indicate the num-
ber of hours of service, then return to “0”. (example: Display shows 08
then 54. This equals 854 hours.) NOTE: If the unit is connected to a T-
Max® remote device, it may briefly lose communication with the
remote. This is normal.

To erase the indicated hours, disconnect power from the sunbed. Press
and hold the green timer button as you reconnect power. Release the
button after a few seconds.

Removing/Replacing Lamps

To be assured of maximum tanning effectiveness, change lamps after
approximately 800-1000 hours of use. Tanning will continue after this
time but at a slower rate. To ensure trouble-free operation of your
sunbed, replace the lamp starters whenever the lamps are replaced. We
recommend using the lamps specified below. Use of uncertified lamps
is a violation of Federal regulations and will void your warranty.

1

Grasp a lamp at one end and at the middle, then turn the lamp a
quarter turn. The lamp may then be gently removed from its holder.

2

To reinstall lamp, insert pins on the ends of the lamp into the slots
on top of the lamp holder and turn the lamp a quarter turn.

Page 6  -  27771-01A

Removing/Replacing Acrylic Shields

The acrylic shields are secured in place by hinged profiles which run
the length of the bed, both front and back. Simply pry up on the inside
edge of the profile until it releases its latching action (see figure
below). Continue to pry up the profile across its entire length until it
swings back freely. Repeat for the other profile. The long edges of the
acrylic shield are now exposed. Standing in front of the sunbed, grasp
the long exposed edge of the acrylic and carefully slide it toward you
until it is removed.

After changing the lamps, replace the acrylic shields by reversing the
above directions. Close the hinged profile by pushing it back into
place until it snaps tight.

PROFILE

CAUTION

Be careful. The edges of the
acrylic shield may be sharp.

Start pulling from the

middle of the profile!

The following lamps have been certified for use in the Lumagen™ 26C:

Velocity® Wolff® Model VEL 71-T12-100W
Lumalite C™ Wolff® 

P/N 27743-01

DermaSun™ Wolff® 

P/N 27744-01

Содержание Lumagen 26C

Страница 1: ...roducts under 21 CFR PART 1040 20 and ANSI UL Standard 482 WARNING Wear protective eyewear Failure to may result in severe burns or longterm injury to the eyes DANGER Shock hazard Disconnect power bef...

Страница 2: ...s into the endcap threaded inserts until snug then an additional half turn Do not overtighten to avoid damaging threaded inserts 6 PIVOT STUD CAUTION Failure to engage locking clips may result in the...

Страница 3: ...arameters 5 6 7 8 9 10 15 and 23 See your T Max manual for descriptions of these parameters and how they function Special Note on T Max The Lumagn 26C requires the latest software in your T Max Manage...

Страница 4: ...tan ning bed The rest of the salon may be daisy chained together and connected to the Manager Scenario 4 T Max Manager Pro Series with wires As always this tanning bed is fully compatible with a wired...

Страница 5: ...ton D to turn Lumagen off if desired 2 Lift the canopy lie down on the bench face up lower the canopy as close to your body as possible with no less than 2 between the canopy acrylic and your body 3 W...

Страница 6: ...rvice then return to 0 example Display shows 08 then 54 This equals 854 hours NOTE If the unit is connected to a T Max remote device it may briefly lose communication with the remote This is normal To...

Страница 7: ...Raise and lower the canopy a few times to lubricate gas spring internal seals 2 Replace gas springs Problem Troubleshooting Solution My bed won t work with the T Max Manager remote system 1 The sunbe...

Страница 8: ...IED INCLUDING ANY IMPLIED WARRANTIES OF MER CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY DISCLAIMED No one has the authority to change or modify this 18 Month Bronze Medal Warran...

Отзывы:

Похожие инструкции для Lumagen 26C