ETS-Lindgren 8000-002 Скачать руководство пользователя страница 21

 

www.ets-lindgren.com 

Warranty 

21 

 

Appendix A:  Warranty 

Scope and Duration of Warranties 

Seller warrants to Buyer that the Products to be delivered hereunder will be (1) free 

from defects in material, manufacturing workmanship, and title, and (2) conform to 
the Seller’s applicable product descriptions and specifications, if any, contained in or 
attached to Seller’s quotation. If no product descriptions or specifications are 
contained in or attached to the quotation, Seller’s applicable product descriptions and 
specifications in effect on the date of shipment shall apply. The criteria for all testing 
shall be Seller’s applicable product specifications utilizing factory-specified calibration 
and test procedures and instruments. 

All product warranties, except the warranty of title, and all remedies for warranty 

failures are limited to three years. 

Product Warranted 

Duration of Warranty Period 

Model 8000-002 RF Power Amplifier 

Three Year(s) 

Any product or part furnished to Buyer during the warranty period to correct a 

warranty failure shall be warranted to the extent of the unexpired term of the warranty 

applicable to the repaired or replaced product. 

The warranty period shall commence on the date the product is delivered to Buyer; 

however, if Seller assembles the product, or provides technical direction of such 

assembly, the warranty period for such product shall commence on the date the 

assembly of the product is complete. Notwithstanding the foregoing, in the event that 

the assembly is delayed for a total of thirty (30) days or more from the date of 

delivery for any reason or reasons for which Seller is not responsible, the warranty 
period for such product may, at Seller’s options, commence on the thirtieth (30th) day 
from the date such product is delivered to Buyer. Buyer shall promptly inspect all 

products upon delivery. No claims for shortages will be allowed unless shortages are 

reported to Seller in writing within ten (10) days after delivery. No other claims 

against Seller will be allowed unless asserted in writing within thirty (30) days after 

delivery (or assembly if the products are to be assembled by Seller) or, in the case of 

alleged breach of warranty, within the applicable warranty period. 

Содержание 8000-002

Страница 1: ...Model 8000 002 RF Power Amplifier User Manual ...

Страница 2: ...rein nor does it convey any license under its patent rights nor the rights of others All trademarks are the property of their respective owners Copyright 2014 by ETS Lindgren Inc All Rights Reserved No part of this document may be copied by any means without written permission from ETS Lindgren Inc Trademarks used in this document The ETS Lindgren logo is a registered trademark and Calibration Ser...

Страница 3: ...fore You Begin 13 Unpacking 13 Safety Information 13 Warnings 14 5 0 Installation 15 Mains Input 15 Amplifier Protection 15 6 0 Operation 17 Equipment Use 17 Mains Switch 17 Standby Operate Switch Centre Unit 17 Fault Indicator Red LED 18 Interlock Indicator Orange LED 18 Local Lockout Indicator 18 RF Input Either Front or Rear Panel Mounted 18 RF Output Either Front or Rear Panel Mounted 18 Air I...

Страница 4: ...iv www ets lindgren com Buyer s Remedies 22 Appendix B EC Declaration of Conformity 25 ...

Страница 5: ...tated maximum input level as this can cause a risk of damaging the equipment Warning There is a significant risk of an electrical or burn hazard to avoid this always ensure the output is terminated prior to switching on the equipment Protective Earth Ground Safety Ground Indicates protective earth terminal You should provide uninterruptible safety earth ground from the main power source to the pro...

Страница 6: ...vi www ets lindgren com This page intentionally left blank ...

Страница 7: ...t faulty cooling by excess temperature sensing A front panel fault indicator is provided to indicate over temperature The amplifier is designed for rugged operation into a variety of loads and is primarily intended for use as an RF power source for EMC susceptibility testing but is also applicable to other systems requiring a wide band linear amplifier This amplifier is designated as Professional ...

Страница 8: ...8 Introduction www ets lindgren com This page intentionally left blank ...

Страница 9: ...e cabinet using a damp cloth Service Procedures CONTACTING ETS LINDGREN Note Please see www ets lindgren com for a list of ETS Lindgren offices including phone and email contact information SENDING A COMPONENT FOR SERVICE 1 Contact ETS Lindgren Customer Service to obtain a Service Request Order SRO 2 Briefly describe the problem in writing Give details regarding the observed symptom s or error cod...

Страница 10: ...10 Maintenance www ets lindgren com This page intentionally left blank ...

Страница 11: ...y Range Instantaneous 80MHz 1000MHz Rated Output Power 275W Minimum Output Power at 1dB Gain Compression 250W Minimum Gain 64dB Minimum Third Order Intercept Point 64dBm Gain Variation with Frequency 3dB Harmonics at 200W Output Power Better than 20dBc Output Impedance 50 Ohms Stability Unconditional Output VSWR Tolerance Infinity 1 Input VSWR 2 1 RF Connector Style Type N Female Safety Interlock ...

Страница 12: ...12 Specifications www ets lindgren com This page intentionally left blank ...

Страница 13: ...pping carton and packing material for the carrier s inspection Check that the equipment is complete and is in an undamaged condition and then contact ETS Lindgren Customer Service for further advice Safety Information This RF amplifier has been designed and tested in accordance with BS EN61010 1 and has been supplied in a safe condition This manual contains warning information which must be follow...

Страница 14: ...the apparatus are in good condition The mains plug shall only be inserted in a socket outlet provided with a protective earth contact The protective action must not be negated by the use of an extension cord without a protective conductor The opening of covers or removal of parts is likely to expose live parts This apparatus must only be serviced by qualified service personnel and must be disconne...

Страница 15: ...put Mains input is via a 15A power cable supplied Amplifier Protection The amplifier is protected by a fuse of the following rating T 15A H 250V 20mm This instrument must be earthed WARNING If the rack mounting option has been selected the unit must be installed in the rack using a suitable tray or runners The amplifier must not be supported only by the front panels ...

Страница 16: ...16 Installation www ets lindgren com This page intentionally left blank ...

Страница 17: ...ensure the output is terminated into a suitable load prior to switching on the equipment Equipment Use The equipment must only be used for its intended purpose All parts of the equipment must remain connected to ensure that protective circuits operate Disconnecting parts of the equipment may impair operation and safety Mains Switch The amplifier is switched on or off by pressing the mains switch o...

Страница 18: ...when the interlock is released Local Lockout Indicator This indicator is used when the USB GPIB option is fitted Refer to the separate Remote Control Interface manual supplied RF Input Either Front or Rear Panel Mounted The RF input will accept a signal from an RF generator This input must be within the operating frequency range of the 8000 002 amplifier An amplitude of up to 0dBm will be sufficie...

Страница 19: ...Interlock must be O C If the Interlock is O C or the Interlock is S C the amplifier will be muted The amplifier is delivered without the interlock applied and will be ready to operate The interlock function is latching so when the interlock is removed the amplifier will be in standby mode Press the standby operate switch to return to normal operation Current drawn from the interlock BNC connectors...

Страница 20: ...20 Operation www ets lindgren com This page intentionally left blank ...

Страница 21: ... to correct a warranty failure shall be warranted to the extent of the unexpired term of the warranty applicable to the repaired or replaced product The warranty period shall commence on the date the product is delivered to Buyer however if Seller assembles the product or provides technical direction of such assembly the warranty period for such product shall commence on the date the assembly of t...

Страница 22: ...er s product with any product furnished by others 7 combining incompatible products of Seller 8 interference with the radio frequency fields due to conditions or causes outside the product as furnished by Seller 9 improper or extraordinary use of the product or failure to comply with any applicable instructions or recommendations of Seller including maintenance calibration and cleaning procedures ...

Страница 23: ...T INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING OUT OF OR AS A RESULT OF THE SALE DELIVERY NON DELIVERY SERVICING ASSEMBLING USE OR LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF OR FOR ANY CHARGES OR EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER S WRITTEN CONSENT DESPITE ANY NEGLIGENCE ON BEHALF OF THE SELLER IN NO EVENT SHALL SELLER S LIABILITIES UNDER ANY CLAIM MADE BY BUYER EXCEED ...

Страница 24: ...24 Warranty www ets lindgren com This page intentionally left blank ...

Страница 25: ...age Directive 2006 95 EC Model 8000 002 RF Power Amplifier Emission EN 61326 1 2006 Class A Electrical equipment for measurement control and laboratory use Immunity EN 61326 1 2006 Industrial level performance criteria A Electrical equipment for measurement control and laboratory use Safety EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use Tech...

Отзывы: