7 | 10
3-a
After the removal of doors untighten the screws on the
plate with cable glands and remove the plate.
If using the bigger gland, make sure that the rubber
inside the gland is of correct size. For the cables with
dimensions up to 5x6 mm
2
use the tighter rubber seal.
For the cables with dimension of 5x10 mm
2
use a looser
rubber seal which should be already inside the gland by
default.
You can change the rubber seal with removal of the
gland plastic top (unscrew it) and by simply pushing the
rubber seal out of the gland. After the new rubber seal is
inserted into the cable gland, screw the plastic gland top
back on.
4
Wires Preparation
Proceed with preparation of cables. Prepare power
supply cables from which cable jacket needs to be
removed. Around 15 cm should be removed so that the
wires lengths are sufficient to connect them to the
elements inside the charging station.
You can now pull the power supply cable through the
gland. About 15 cm of power supply cable should be
pulled to the other side of the gland. About 2 cm of cable
jackets should be pulled through the cable gland as well.
This will make cable manipulations inside the charging
station easier and it will completely seal the gland. Make
sure that the cable is fastened securely with the gland so
that it cannot be pulled out. You can tighten the gland by
turning the plastic gland top in clockwise direction.
4-a
Strip the wires of insulation using special pliers and
attach cable ferrules on the end of the wires, and a cable
ring for grounding wire.
Length of cables on the other side of the gland should be:
a.
Power supply cables (L1, L2, L3, N): 15 cm with
insulation and stripped cable 2 cm with
cable jacket
b.
Grounding cable: 10 cm