  7    |   10 

 

3-a 

After the removal of doors untighten the screws on the 

plate with cable glands and remove the plate. 

 

If  using  the  bigger  gland,  make  sure  that  the  rubber 

inside  the  gland  is  of  correct  size.  For  the  cables  with 

dimensions  up  to  5x6 mm

use  the  tighter  rubber  seal. 

For the cables with dimension of 5x10 mm

2

 use a looser 

rubber seal which should be already inside the gland by 

default. 

 

You  can  change  the  rubber  seal  with  removal  of  the 

gland plastic top (unscrew it) and by simply pushing the 

rubber seal out of the gland. After the new rubber seal is 

inserted into the cable gland, screw the plastic gland top 

back on. 

 

 

Wires Preparation 

Proceed  with  preparation  of  cables.  Prepare  power 

supply  cables  from  which  cable  jacket  needs  to  be 

removed. Around 15 cm should be removed so that the 

wires  lengths  are  sufficient  to  connect  them  to  the 

elements inside the charging station. 

 

You  can  now  pull  the  power  supply  cable  through  the 

gland.  About  15  cm  of  power  supply  cable  should  be 

pulled to the other side of the gland. About 2 cm of cable 

jackets should be pulled through the cable gland as well. 

This  will  make  cable  manipulations  inside  the  charging 

station easier and it will completely seal the gland. Make 

sure that the cable is fastened securely with the gland so 

that it cannot be pulled out. You can tighten the gland by 

turning the plastic gland top in clockwise direction. 

4-a 

Strip  the  wires  of  insulation  using  special  pliers  and 

attach cable ferrules on the end of the wires, and a cable 

ring for grounding wire. 

 

Length of cables on the other side of the gland should be: 

a.

 

Power supply cables (L1, L2, L3, N): 15 cm with 
insulation and stripped cable  2 cm with 
cable jacket 

b.

 

Grounding cable: 10 cm

 

Содержание INCH LITE

Страница 1: ...Ver 2020 08 EN Etrel INCH LITE QUICK START GUIDE EN...

Страница 2: ......

Страница 3: ...harging station has been designed and tested in accordance with current and past versions of international standards The charging station is compliant with IEC 61851 Part 1 Part 21 2 Part 22 internati...

Страница 4: ...trical codes legislation and ordinances Warning Before installing and wiring the charging station make sure that the power supply is disconnected remove fuses or deactivate the circuit breaker to prot...

Страница 5: ...ll modules are part of an actual device LTE module Frequency bands LTE FDD B1 2100 MHz B3 1800 MHz B5 850 MHz B7 2600 MHz B8 900 MHz B20 800 MHz LTE TDD B38 2600 MHz B40 2300 MHz B41 2500 MHz WCDMA B1...

Страница 6: ...d with an upstream overvoltage protection Overcurrent protection Should be installed upstream to protect power supply cable and the charging device Differential protection Should be installed separate...

Страница 7: ...Optional depending on the purchased model INSTALLATION PROCEDURE The following descriptions are intended to be read together with appropriate image at the beginning of the document The bold number at...

Страница 8: ...stallation should be around 40 cm Align holes of the mounting bracket with the drilled holes and tighten the screws using Phillips head screwdriver B2 Alternative Power Supply Cable Preparation When s...

Страница 9: ...15 cm should be removed so that the wires lengths are sufficient to connect them to the elements inside the charging station You can now pull the power supply cable through the gland About 15 cm of p...

Страница 10: ...tripping of RCD protection insert the additional wire with fork into the slot for neutral conductor like shown on the figure This applies only if RCD is installed in the charging station 8 Connecting...

Страница 11: ...you remove the charging station from the station holder To attach it align the holes on the cable holder hook with holes on the plate attached to the enclosure 11 Check Whether the Charging Station i...

Страница 12: ...tation can last up to 10 minutes Make sure that the status light is lit in solid green This means that the charging station is ready to charge an EV For more documentation and troubleshooting please v...

Отзывы: