background image

EFP Series Sewage & Drainage Pump 

User Manual

Содержание EFP 11 D

Страница 1: ...EFP Series Sewage Drainage Pump User Manual ...

Страница 2: ...hat contain people and obligates the use of the versions with a 10m cable for outdoor use Pump working conditions are not corresponded these fluid properties Fluid is over 35 C temperature over 1000 kg m3 density over 1mm2 s kinematic viscosity Chemicals that may be harmful to the pump material and fluids containing solids larger than the pump permeability described in the table given Flammable an...

Страница 3: ...ls with filters 7 Safety Information The pump is not suitable for pumping flammable or dangerous liquids Do not use the energy cable to carry or lift your pump Do not run the pump dry out of the water Since the pump runs and stops automatically do not put your hands or other objects in between when it is connected to the mains Pay attention to the limitations of use Inappropriate use may damage th...

Страница 4: ...e three phase models If the pump runs intermittently The floater switch adjusted wrong The container of the pump is very small The current withdrawn from the electrical panel is high The pump or the pipes are clogged 9 Noise If the pump runs partially under water the noise level should be less than 70 db A but this value is not applicable when the pump runs completely under water 10 Installation T...

Страница 5: ... that will not rot and connect it to the handling ring of the pump Always use a chain or a rope to lower lift or move the pump if you have a plastic or flexible discharge pipe Never pull out from the power cable because it will damage the pump Connect the power cable to the lifting chain or the rope using proper connectors Leave a sufficient space for the cable to move since there will be extra we...

Страница 6: ...ocess When maintenance for the pump is desired to be carried out the pump is pulled up using a chain cleaned by spraying clean water with a hose easily taken out and its maintenance is carried out The pump is lowered back into the well on the sledge after maintenance and will be easily made ready for operation It is recommended to use a strong chain when suspending the pump down on the sledge Mf C...

Страница 7: ...00 130 110 100 58 104 390 465 2 EFP 11 D 320 EFP 22 DP 195 462 220 530 410 420 50 EFP 22 D TYPE DIMENSIONS mm Cf Df1 Df2 Hf mf Mf DNm EFP 11 DV 450 200 253 120 320 425 2 EFP 26 DT 546 220 300 110 403 503 65 EFP 26 DV Mf Cf mf Cp Hf Af Gf Bf Dp2 Df2 Df1 Is Ls 13 I1 13 G2 Mf Cf mf Df1 Hf DNm Df2 DNm I1 I2 13 Is Ls 13 Mf Cf mf Cp Hf Af Gf Bf Dp2 Df2 Df1 Figure 6 Figure 7 Mf for continuous operation t...

Страница 8: ...EDGE UPPER BRACKED SLEDGE FIXED ELBOW 585 WELL TOP VALVE UNION Concrete Septic Tank and Waste Water Drainage Pump İnstallation Details with Sledge System NOTE Concrete well can be in the desired size However the well top should be 620x585 so that the sledge well cover supplied by our firm can be mounted Cover chassis is fitted into the well top and doweled from inside Alternative connection ...

Страница 9: ...5 665 700 565 600 415 50 100 700 565 665 50 150 415 700 665 HINGE COVER 2mm DKP 665 700 400 L50 50 ANGLE BRACKET 585 620 WELL TOP 585x620 SLEDGE TOP BRACKET DUBEL HOLE 575 CONCRETE SURFACE A DETAIL A 5x10 METAL SHEET WILL BE WELDED TO THE ENTIRE FRAME ...

Страница 10: ...10 NOTE ...

Страница 11: ...11 www etna com tr NOTE ...

Страница 12: ...Dudullu Organize Sanayi Bölgesi 2 Cadde No 14 34775 Ümraniye Istanbul Turkey Tel 90 216 561 47 74 Pbx Fax 90 216 561 47 50 www etna com tr en info etna com tr ...

Отзывы: