background image

 

 

 

 

5. MOUNTING 

5.1 Preparation 

 

Check that the delivery is complete. 

 

Check if all accessories for your installation situati-
on are present (e.g. bracket). 

 

Check if the system has a suitable mains connec-
tion and a mains switch. 

 

Remove all unnecessary components from the door 

 

Remove all devices, which are not required after 
installation of the drive system. 

 

Before installation, ensure that the operator is not 
blocked,  

 

Before installation, ensure that the operator has 
been newly prepared after a lengthy storage period, 

 

Before installation, ensure that no other sources of 
danger are present,  

 

Before installation, ensure that the installation site 
has been cordoned off over a wide area. 

 

5.2 Mounting the Operator 

 

Install the torque bracket 

 

Insert the feather key into the shaft 

 

The shaft end is greased before fitting the drive 

 

When using collars, slide the collar onto the shaft  

 

Secure the feather key against sliding  

 

Connect the drive to the shaft  

 

Attach the drive to the bracket 

 

Slide the counter bearing onto the shaft 

 

Attach the counter bearing to the bracket 

 

The brackets must be mounted so that the shaft is 
in the horizontal 

 

The fixation against axial displacement of the shaft 
is made on the opposite side at counter bearing, by 
means of a screw or with collars on both sides 

 

 

DANGER ! 

All components must be designed in relation to the 
construction and the ground for the loads during tripping 
of the safety catch device. 

NOTICE ! 

 

To avoid damage to the operator and to the door, the 
operator must be mounted on a bracket with a pen-
dulum foot or a torque  support bracket so that it is 
vibration dampened. 

 

When mounting the operator do not carry or pull at 
the cable. 

DANGER ! 

With a continuous shaft groove the feather key has to 
be secured against moving. 

Содержание RDA series

Страница 1: ...OPERATING INSTRUCTIONS ROLLING DOOR OPERATORS...

Страница 2: ......

Страница 3: ...as a result of the warnings and safety advice being disregarded The CE declaration and the warranty will void if com ponents are changed Only original spare parts and by the manufacturer ap proved acc...

Страница 4: ...nd at the door the drive must be mounted only if the drive is undamaged the ambient temperature is 20 C to 60 C the installation site altitude does not exceed 1 000 m above sea level The use of the op...

Страница 5: ...aft end is greased before fitting the drive When using collars slide the collar onto the shaft Secure the feather key against sliding Connect the drive to the shaft Attach the drive to the bracket Sli...

Страница 6: ...trained person before first use and as re quired with written proof The operator of the door system shall be trained after initial operation Before installation ensure that the direction of rotation o...

Страница 7: ...by pulling the cables Kabelsatz Cable U1 BN PE W1 BL BU V1 SW BK leer empty Kabelsatz cable U1 BN PE W1 BL BU V1 SW BK leer empty NOTICE When used with frequency converter control units only shielded...

Страница 8: ...ting the OPEN end position Bring the door in the OPEN end position Set the cam so that the OPEN limit switch is actua ted Tighten the locking screw The Safety limit OPEN switch must be set so that it...

Страница 9: ...r is stationary The system must be disconnected from the power supply during emergency operation Emergency operation must only be carried out from a safe standing position Operators with a spring brak...

Страница 10: ...releases the control system The door can be operated electrically again 7 10 Hand chain By pulling the release lever the coiler shaft of the hand chain system is shifted and thus switches between moto...

Страница 11: ...e separa ted from the coil chain using a bolt cutter The coup ling links must be carefully bent together When making changes to the coil chain make sure that the chain is not twisted when mounted chai...

Страница 12: ...et tigung Type of manual operation Schutzart Protection Category Gewicht Weight MA Nm MN Nm n2 min 1 TOR FV i Stw D mm U V P kW S3 IN A L1 mm IP G kg RDA 140 18 140 115 18 5 083 15 30 3 230 3 400 0 55...

Страница 13: ...g B Ma bild C Drawing C Ma bild D Drawing D Ma bild E Drawing E Ma bild Notbet tigung Manual Override 195 5 66 L1 64 120 115 135 110 120 162 L1 64 135 135 90 148 120 217 L1 64 135 135 139 148 L1 182 1...

Страница 14: ...ay be used The use of non original spare parts and accessories may affect the functionality and the safety of the system For damages incurred thereby any lia bility and warranty is excluded In the cas...

Страница 15: ...0 6 3 EN 60335 1 EN 60335 2 103 Manufacturer and technical documentation management ETME GmbH Flohrstr 33 D 13507 Berlin The relevant technical documentation is compiled in accordance with Annex VII B...

Страница 16: ...lectric shock Before commencing cabling works you MUST dis connect the drive system from the mains supply Ensure that the electricity supply remains disconnec ted throughout the cabling works NOTICE I...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...orantriebe Steuerungen Sicherheitssysteme Zubeh r ETME PRODUKTE Operators for Roller Shutters Chain Wheel Operators Operators for Sectional Doors High Speed Doors Operators for Sliding Gates Controls...

Отзывы: