ETM8100 Series Quick Start GuideV002 

Introduction 

Nomenclature 

The 2G only ETM8120 variants incorporate the Cinterion TC63i engine and are intended for 
worldwide use (network and regulatory approvals permitting). 

 

The 3G/2G ETM8140 variants incorporate the Cinterion PHS8-P engine and are intended for 
worldwide use (network and regulatory approvals permitting). 

Overview. 

The ETM8xxx-xxx range of products are compact industrial terminals designed for M2M (Machine 
to Machine) communications. 

 

Terminal Nomenclature/History 
Model 

Comment 

Module Installed 

ETM8120 Variants 

ETM8120-1 

RJ45 socket for serial and 
power connection 

TC63i 

ETM8120-4 

RJ45 plug on approx. 120mm 
cable for serial and power 
connection 

TC63i 

ETM8130/8140 Variants 

ETM8130-1 

RJ45 socket for serial and 
power connection 

EU3-P 

ETM8140-1 

RJ45 socket for serial and 
power connection 

PHS8-P 

ETM8140-4 

RJ45 plug on approx. 120mm 
cable for serial and power 
connection 

PHS8-P 

Applications 

Typical applications include: 

 

General M2M communications device 

 

Automated Meter Reading (Telemetry) 

 

Interface to data acquisition/data logging systems 

 

Interfacing with alarm and control applications 

 

Temperature monitoring and alarm 

 

Water metering 

 

Rainfall monitoring 

Содержание ETM8120-1

Страница 1: ...140 1 ETM8140 4 only 2G GSM GPRS Connectivity 4v to 35v power input Combined serial and power input on RJ45 connector 4 x I O s 6 pin Minibridge connector FME M antenna connector Sleep Mode for reduce...

Страница 2: ...or 4 Antenna 5 SIM Card 5 SIM Pin 5 Indicator Lights 6 LED indication during runtime 6 Installation 7 Configuration Tool 7 Using the Right Version of the Configuration Tool 7 Using the Configuration T...

Страница 3: ...chine communications Terminal Nomenclature History Model Comment Module Installed ETM8120 Variants ETM8120 1 RJ45 socket for serial and power connection TC63i ETM8120 4 RJ45 plug on approx 120mm cable...

Страница 4: ...d Adaptor Cable The following adaptor cable is available from ETM for ease of connection to the modem when programming and testing Adaptor Cable for Programming ETM8xxx xxx Modems White red positive 4...

Страница 5: ...o be used for remote access to a device a terminating data number for Circuit Switch Data CSD MAY need to be provisioned by the network operator this number will usually differ from any voice SMS numb...

Страница 6: ...ff 75ms on 1990ms off One or more UMTS PDP contexts activated YELLOW LED mode Function Flashing Busy with communication with the Module 0 5s On 0 5s Off Waiting for answer from the Module On When conn...

Страница 7: ...Note that for Telstra you will need to request 2620 bearer capability Telstra NextG Sims 4 Connect the power supply The unit accepts a broad range of voltages from 4 to 35VDC take care the unit does n...

Страница 8: ...layed you CANNOT perform any configuration on the wireless modem while it is possible to use the Configuration Tool once the wireless modem has fully started up this may not be possible if the wireles...

Страница 9: ...e ETM8xxx xxx modem needs to be set as above with both the UMTS GPRS Module and MCU Port Settings being the same plus the internal engine module TC63i PHS8 P must be set to the same baud rate using AT...

Страница 10: ...mmand where xxxx is the desired baud rate note this speed setting will need to match the settings under the Settings tab Note the Com Port will need to be set to the current module baud rate for the c...

Страница 11: ...ll occur when the unit is started in run mode To solve the above problem wait until the ETM9910 SYSTEM START message appears and press the ESC key to put the unit into escape mode for programming if s...

Страница 12: ...etmpacific com au ETM8100 Series Quick Start GuideV002 Normal Typical Start Sequence Upon re starting the modem with the port set to the correct speed you should see the following typical start up seq...

Страница 13: ...e useful for programming the unit over a dial up connection NOTE Incoming CSD calls are only possible on UMTS WCDMA when the modem does not have an IP Address allocated is not connected to the interne...

Страница 14: ...recommended that more complex settings such as changing messages or phone numbers are made using the configuration tool Common ET commands are shown on the next two pages for a full ET command list c...

Страница 15: ...Page 15 of 17 For Support Contact 61 2 9956 7377 Or support etmpacific com au ETM8100 Series Quick Start GuideV002...

Страница 16: ...ction to Output and Set pin level for a specified time period ETS X DO 0 TAY Sets I O No X to low for Y seconds then reverts to High Y is in whole minutes 8 Set IO pin selection to analogue I O set di...

Страница 17: ...Fax 46 0 8 80 11 10 Email etm etm se Web www etm se ETM Pacific Pty Ltd LGF 275 Alfred Street North Sydney NSW 2060 Australia Tel 61 0 2 9956 7377 Fax 61 0 2 9956 5791 Email info etmpacific com au We...

Отзывы: