background image

18

19

Housing material

ABS plastic

Operating temperature

-10°C~55°C

Relative humidity

≤80% (non-condensing)

Transmitter dimensions (LxWxH)

71 x 34 x 17.5 mm

Magnet dimensions (LxWxH)

51 x 12 x 13.5 mm

Wireless PIR Motion Detector  

 

Features

ES-D1A (or ES-D2A: Pet-Immune Motion 

Detector) is a high performance wireless 

P.I.R. motion detector. It boasts a digital 

dual-core fuzzy logic infrared control chip 

with intelligent analysis. This technology 

identifies interferences created by body 

motion and reduces the false alarm rate.

With automatic temperature compensation 

and anti-air turbulence technology, it easily 

adapts to environmental changes. 

3

1

2

1. LED indicator

2. Detection window

3. Bracket

LED indications

Blinks continuously: self-testing 

Blinks once: an intruder is detected

Blinks twice: self-testing is complete; entering 

working mode.

Blinks once every 3 seconds: under-voltage 

indication: the batteries must be replaced. 

(The user will be informed by SMS when the 

batteries are low if the PIR Motion Detector is 

registered in the control panel.)

PCB Layout

Alarm zone setup
Tamper switch

Infrared sensor

AA 1.5V  LR6

Antenna

LED working indicator

  Infrared sensor

  Detects the infrared rays released by human 

body motion. Do not touch the surface. Keep 

the surface clean.

  Tamper switch

  When the alarm system is armed, the tamper 

switch will trigger the alarm if the case is 

opened.

 

Usage

Open the case and remove the battery 

activation strip to activate the batteries. Self-

testing will start for one minute.

Mode Setting

Test Button

Testing mode

Once the self-testing is complete, press the 

test button. The sensor switches to testing 

mode, and scans once every 10 seconds. 

After 3 minutes, the LED blinks twice, and 

the sensor switches to working mode.

Working mode

In working mode, if the sensor is triggered 

more than twice within 3 minutes, it will 

switch to standby mode to save power. If 

a movement is detected within the next 

3 minutes, the standby mode is extended 

by 3 more minutes. If no movement has 

detected within these 3 minutes, the 

detectors turns back to working mode.

Register in the control panel

Press the Connect button { } on the control 

panel. Press the test button of the sensor 

twice. The control panel beeps once: the 

motion detector is registered.

To check if the registration is complete, arm 

the system and trigger the sensor again. 

If the siren rings out, the registration is 
successful.

Installation

Avoid mounting the detector close 

to windows, air conditioner, heater, 

refrigerator, oven, sunshine and places 

where the temperature changes fast or 

where the air stream flows frequently.

  If two detectors are installed in the same 

detection scope, adjust the location to avoid 

interferences and false alarms.

Top

Bottom

Ground

2.2 m

Side view

Top view

Fix the bracket on the wall with screws and 

attach the detector to the bracket. Adjust 

the bracket to change the detection distance 

and angle. It is recommended to mount the 

detector 2m from the ground.

The detector is more sensitive to cross 

movements than vertical movements.

Testing

A. After one minute of self-testing, press the 

test button, walk in the scope of detection 

and watch the LED indicator to make sure the 

detector is working.

B. The LED indicator blinks once when body 

movement is detected.

C. Adjust the detector angle to achieve the best 

detection performance.

Содержание S3 Sim Secual

Страница 1: ...www etiger com S3 Sim Secual Alarm system with GSM transmitter ...

Страница 2: ...s Indicator Record Voice Memo Connect Button Stay Arm Home Mode RFID player Play Voice Memo Call Arm Disarm Control Panel Layout Back MIC Siren Speaker Tamper Switch Loudspeaker Back up Batteries SIM Card Slot Power On Off Input for Wired Sensors 24 hour zone Input for Wired Sensors normal zone Adapter Interface Output for Wired Siren 500mA Output for Electronic Lock Box Content S3 Panel x1 AC Ada...

Страница 3: ... automatically SMS Operations Important Insert a SIM card in the control panel before starting SMS operations Make sure the SIM card does not request any PIN code Each SMS operation included in this user manual will be illustrated as follows You send SMS Command The first blue speech bubble is the SMS command sent by the user The control panel replies Control panel s reply The first grey speech bu...

Страница 4: ...start the two way talk Call Back to Record a Voice Memo Send 4 The system will call you back Pick up the phone and leave a 10 second message The call end automatically after 10 seconds Settings Enquiry Send 00 System status Entry and exit delay time 0sec Single zone delay time 30sec Siren volume 2 Siren ringing time 5min Disarm password 1234 Note The value of default settings will be changed after...

Страница 5: ...her tags will be attributed a number based on the order of registration to the control panel Refer to the instructions page 14 to learn how to register an RFID tag in the control panel Store Speed Dial Phone Number Send 8 Speed dial phone number 0 20 digits 1 Copy Paste then Edit case sensitive Speed dial phone number 0 20 digits 1 67890033 Store speed dial phone number successfully Change Zone Na...

Страница 6: ...Change RFID Tag SMS Notice successfully Note To start receiving an SMS notification when the system is diarmed by RFID tag you must store an SMS number and rename the RFID tags up to 4 RFID tags can be renamed Other tags will be attributed a number based on the order of registration to the control panel Refer to the instructions page 14 to learn how to register an RFID tag in the control panel Ent...

Страница 7: ...ge system as French 0033 Réglage de la langue français réussi Send 0001 to set the language system as English 0001 Set English successfully Delete Wireless Accessories by SMS Send 21 Delete wireless accessories successfully Delete RFID Tags by SMS Send 22 Delete RFID tags successfully Press the Tamper Switch at the back of the controlpanel3timesin3seconds bothwireless accessories and RFID tags wil...

Страница 8: ...ted both the internal siren and the wireless siren will ring out The siren will turn off after 5 minutes as per default setting Important When the alarm is triggered the alarm system sends an SMS and calls the stored numbers If one of the users answers the call the siren stops immediately and audio monitoring of the site starts Alarm System Specifications Product name S3 Sim Secual Model S3 S Cont...

Страница 9: ... 24 H Zone D3 D0 Note It is recommended to set the smoke detector the gas detector and the outdoor beam sensor at 24 H zone Wireless Door Window Contact Features The ES D3A is a Door Window Contact that can be installed on doors windows and any other objects that open and close The sensor sends signals to the control panel when the magnet installed next to the sensor is deconnected Thanks to the t...

Страница 10: ...is complete press the test button The sensor switches to testing mode and scans once every 10 seconds After 3 minutes the LED blinks twice and the sensor switches to working mode Working mode In working mode if the sensor is triggered more than twice within 3 minutes it will switch to standby mode to save power If a movement is detected within the next 3 minutes the standby mode is extended by 3 m...

Страница 11: ...nment For further information please contact your local or regional authorities Electronic products not included in the selective sorting process are potentially dangerous for the environment and human health due to the presence of hazardous substances In compliance with European laws This product was designed and manufactured in compliance with Directive 2002 95 EC of the European Parliament and ...

Страница 12: ...www etiger com ...