STARTUP
XSLAN-140 shdsl switch
User manual ref 9017209-01
Page 15
Setting up the XSLAN 2 :
XSLAN 2
SW 3 SW 4 SW 5 Shdsl port
OFF OFF OFF NTU mode
Step 3 : Connecting the products to the line
Connect the products to the line using the CAB 614 cable.
Nota bene : For test purposes, any straight RJ45 cable can be connected
to each XSLAN-140 SHDSL RJ45 connector.
Step 4 : Check the connection
The lower green led of the SHDSL RJ45 connector blinks during the
SHDSL negotiation and then remains lit when the connection is
established.
If the Line led (lower green led of the SHDSL RJ45 connector)
blinks
permanently
, it means that the connection cannot be
established; check the wires connection and eventually, set a lower
data rate with the DIP switches SW03, SW04, SW05.
If the Error led (upper red led of the SHDSL RJ45 connector)
blinks
, it means that errors occur on the line, check the wires
connection and eventually, set a lower data rate with the DIP switches
SW03, SW04, SW05.
Step 5 : exchange data through the line
Connect a PC to one of the XSLAN-140 and transmit periodical PING to
the other XSLAN-140.
Check an answer is received within less than 10 ms.