XSLAN-140 

SHDSL Switch

  

_________________ 

 

User manual 

Document reference : 

9017209-01

 

_________________ 

 
 
 
 

 

 

Содержание XSLAN-140

Страница 1: ...XSLAN 140 SHDSL Switch _________________ User manual Document reference 9017209 01 _________________ ...

Страница 2: ...DSL switch is manufactured by ETIC TELECOMMUNICATIONS 13 Chemin du vieux chêne 38240 MEYLAN FRANCE TEL 33 4 76 04 20 00 FAX 33 4 76 04 20 01 e mail infos etictelecom com web www etictelecom com Hotline TEL 33 4 76 04 20 05 FAX 33 4 76 04 20 01 e mail hotline etictelecom com ...

Страница 3: ...1 5 ETHERNET PORTS 11 6 SHDSL LINE CONNECTION 12 STARTUP 1 SETTING UP THE SHDSL CONNECTION 13 DIAGNOSTIC MAINTENANCE 1 CONNECTING A PC TO THE XSLAN SERVER 16 1 1 Connecting the PC directly to the Ethernet RJ45 of the XSLAN 16 1 2 Connecting a PC through a LAN 16 1 3 Wrong IP address or password 17 2 CHECKING THE TRANSMISSION QUALITY 18 3 CHECKING SHDSL LINE DISCONNECTIONS 18 4 UPDATING THE FIRMWAR...

Страница 4: ...Page 4 User manual ref 9017209 01 XSLAN 140 shdsl switch ...

Страница 5: ...e data rate is a function of the cable quality and the distance with the other SHDSL switch For instance the maximum distance between 2 switches through a line is 13 Km 8 miles with a 0 9 mm wire diameter cable The table in appendix 1 gives the data rate which can be expected over a line versus the length of the line distance between 2 switches Ethernet ports The XSLAN 140 provides 4 ethernet RJ45...

Страница 6: ... 40 VDC Consumption 4W Operating T 20 60 C non condensing SHDSL ITU T G 991 2 802 3ah 2BaseTL EFM Data rate 128 kb s to 2 3 Mb s with 2 wires Connection delay Auto mode 1 mn Fixed data rate 30 s Latency delay through the line 4 ms at 2 3Mb s 6 ms at 512 kb s Ethernet 4 RJ45 10 100 Mb s Half Full duplex Auto MDI MDIX Switch Store and forward 1024 MAC Configuration Dip switches Diagnostic Html serve...

Страница 7: ...INSTALLATION XSLAN 140 shdsl switch User manual ref 9017209 01 Page 7 1 Product description ...

Страница 8: ...ion leds Description Ethernet LINK DATA Ethernet activity Shdsl line led Green lower led Slowly blinking Shdsl connection in process Lit on Shdsl connection set Quickly blinking Traffic over the SHDSL link Red upper led Off Error free transmission Quickly blinking Transmission errors Shdsl error led Operation Green Ready for use Red Alarm Page 8 User manual ref 9017209 01 XSLAN 140 Shdsl switch ...

Страница 9: ... voltage input 1 9 to 30 Vdc 2 Power 1 0 V 3 Power 2 Supply voltage input 2 9 to 30 Vdc 4 Power 2 0 V 5 6 7 8 SHDSL RJ45 connector Pin Nr Signal Function 1 N C 2 N C 3 N C 4 TIP SHDSL line 5 RING SHDSL line 6 N C 7 N C 8 N C Ethernet RJ45 connector Pin Nr Signal Function 1 Tx TX polarity 2 Tx TX polarity 3 Rx Reception polarity 4 N C 5 N C 6 Rx Reception polarity 7 N C 8 N C ...

Страница 10: ...rd are required to access to the html server OFF ON The active IP is provided by the BOOTP or DHCP server ON ON No IP is assigned to the product DIP switch configuration SW 3 SW 4 SW 5 Shdsl port OFF OFF OFF NTU mode OFF OFF ON LTU mode Auto OFF ON OFF LTU mode 2304 kbit s OFF ON ON LTU Mode 2048 kbit s ON OFF OFF LTU Mode 1536 kbit s ON OFF ON LTU Mode 1024 kbit s ON ON OFF LTU Mode 512 kbit s ON...

Страница 11: ...s can be connected to the product If one power supply module fails the XSLAN 140 will be powered by the other The supply voltage must be strictly lower than 30 VDC and higher than 9 VDC The consumption is 170 mA at 24 VDC 4 Fuse The product is protected with a 3A fuse located on the electronic board near the supply voltage connectors A replacement fuse is available on the board it is located over ...

Страница 12: ... The wires can be inverted Shield If the cable is shielded the shield must be connected at one end directly to the earth Surge voltage arrester if the line is exposed to the lightning we advise to use an over voltage arrester at each end of the line We have selected the Phoenix Contact module TT 2 PE 24D it must be wired as indicated opposite Page 12 User manual ref 9017209 01 XSLAN 140 Shdsl swit...

Страница 13: ...witches SW01 and SW02 settings SW01 and SW02 must be usually set ON and ON In that case no IP address is assigned to the product However in case of line disconnection or errors the html diagnostic server will help to solve the difficulties in that case an IP address can be assigned to the product according to the table below DIP switches SW 1 SW 2 Management OFF OFF The current IP of the product i...

Страница 14: ... OFF OFF and ON auto mode the XSLAN 1 LTU will negotiate the appropriate data rate with the XSLAN 2 NTU The connection delay will be longer To reduce the connection delay select the appropriate position of SW03 SW04 SW05 according to the line length Refer to the table in appendix 1 XSLAN 1 Page 14 User manual ref 9017209 01 XSLAN 140 Shdsl switch SW 3 SW 4 SW 5 Shdsl port OFF OFF ON LTU mode Auto ...

Страница 15: ...d then remains lit when the connection is established If the Line led lower green led of the SHDSL RJ45 connector blinks permanently it means that the connection cannot be established check the wires connection and eventually set a lower data rate with the DIP switches SW03 SW04 SW05 If the Error led upper red led of the SHDSL RJ45 connector blinks it means that errors occur on the line check the ...

Страница 16: ...Create or modify the PC TCP IP connection Assign to the PC an IP in accordance with the XSLAN 140 IP address For the first configuration assign or instance 192 168 0 127 to the PC Step 3 Connect the PC directly to an XSLAN ethernet interface using any Ethernet cable straight or crosswired Step 4 Launch the html browser Enter the IP of the XSLAN 140 The Home page of the administration server is dis...

Страница 17: ...t be displayed the cause may be the IP address you enter or the password you use are wrong if the XSLAN 140 IP address you enter is wrong you can recover the factory IP address by setting SW01 ON and SW2 OFF The factory IP address 192 168 0 128 will be restored as long as the SW01 micro switch will be left ON Once SW01 will be set OFF the stored IP address the IP address which is displayed will be...

Страница 18: ...IP switches of the XSLAN 140 declared as LTU and check the line If the signal quality is 3 5 the connection quality is sufficient Nevertheless the data rate can be decreased with the DIP switches to get a 4 5 signal quality SHDSL errors rate To check the error rate click the Show statistics button Click the Reset button to reset the counters The CRC SHDSL errors counter gives the numbers of errors...

Страница 19: ...owser button Click on Show dir to check the files of the directory jffs2root rfsmini tgz u boot bin and uImage Step 4 Update the firmware Launch the web browser Enter the IP address of the ETIC product the home page of the ETIC configuration server is displayed Select the System menu and then firmware Update In the field IP address of the TFTP server enter the IP address of your PC Note The IP add...

Страница 20: ......

Страница 21: ...le quality XSLAN 140 shdsl switch User manual ref 9017209 01 Page 21 Distance Km 3 4 6 7 8 10 12 0 9 2 3Mb s 2 3Mb s 2 3Mb s 1 5Mb s 1 1Mb s 512Kb s 128Kb s 0 6 2 3Mb s 2 3Mb s 1 1Mb s 256Kb s 128Kb s Wire diam mm 0 4 2 3Mb s 1 1Mb s 256Kb s 128Kb s ...