Installation
Page 12
ETIC - MR1200 - USER MANUAL - 908709-02
VR
S1
+
-
BFin +
BFin -
10
11
S1
P1
IC3
The operation requires the copper track (component side) linking the S1 pins to be cut, and a strap
soldered in position as shown above.
P1 is factory set to give an RX level of 460 mV r.m.s. when a signal of 1500 Hz / 85 mV r.m.s. is
applied to the LFin input.
2.6.1.3. The ALT connection
The T/R 's change over to transmit mode (ALTERNAT command) either happens the instant circuit
105-RTS is set ON, or when the ALT command generated by the data card is asserted .
A monostable triggered by 105-RTS prevents T/R changeover occurring before data transmission has
terminated.
RTS
DATA
ALTERNAT Soft
DATA out
10 ms min
T1= 65 ms max
ALTERNAT E/R
MONOSTABLE
monostable 100 ms